• Title/Summary/Keyword: 신뢰성 시험(reliability test)

Search Result 873, Processing Time 0.032 seconds

A Study on the Standard Architecture of IFF Interface SW in the Naval Combat Management System

  • Yeon-Hee Noh;Dong-Han Jung;Young-San Kim;Hyo-Jo Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.139-149
    • /
    • 2024
  • In this paper, we propose the standard architecture for the IFF interface SW in naval combat management system(CMS). The proposed standard interface architecture is a method designed to reduce modification efforts and man-month of reliability test for the existing the IFF interface SW of 11 types. We identified highly dependent CMS and GFE information, leading to the redefinition of standard requirements and functions, and proceeded with the initial design applying the Naval Shield Component Platform(NSCP). Subsequently, using the Feature Model, we derived additional common and variable elements for the interface of multiple CMS and GFE. Considering the S.O.L.I.D principles, we designed the final architecture. The proposed IFF Interface SW, based on the standard architecture, is expected to enhance management efficiency through a common architecture, increase code reusability and scalability, and reduce development costs by shortening reliability testing times.

Change of I-V Properties of Flexible CZTS Solar Cell Through Mechanical Bending Test (굽힘 시험에 의한 플렉시블 CZTS 태양전지의 I-V 특성 변화에 관한 연구)

  • Kim, Sungjun;Kim, Jeha
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.197-202
    • /
    • 2022
  • The CZTS solar cell is a thin film solar cell using an absorption layer composed of Cu, Zn, Sn, Se, and S, and is cheaper than a CIGS solar cell using In and Ga and more eco-friendly than a perovskite and CdTe solar cell using Pb and Cd. In this study, we conducted a bending test for flexible CZTS solar cells. Experiments were conducted in the direction of inner benidng with compressive stress and outer bending with tensile stress, and during the number of bending 1,000 times with a radius of curvature of 50 mmR, the efficiency of the solar cell decreased by up to 12.7%, and the biggest cause of efficiency reduction in both directions was a large decrease in parallel resistance.

A Study on improvement of communication error between controllers for K56 ammunition transport vehicle (K56 탄약운반장갑차용 제어기 간 통신 오류 개선에 관한 연구)

  • Park, Joo-Young;Kim, Seong-Hoon;Noh, Sang-Wan;Park, Young-Min;Kim, Kyung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.781-788
    • /
    • 2021
  • This paper is the study of a design to eliminate the communication error that occurs between the main controller and the servo controller of the K56 ammunition-carrying armored vehicle. The K56 assists in the operation of the K-55A1 self-propelled gun by automating the supply and loading of ammunition. The CAN communication board of the ammunition carrier is a key-function product mounted inside the main controller and installed for communication with the servo controller. It was confirmed that an undefined error would occur intermittently in the existing CAN communication board, interrupting the operation of the ammunition supply system during the loading process. In this paper, in order to solve the problem, the cause of the failure is identified through analysis and a functional test of the communication signal between the main controller and the servo controller. The error was resolved by redesigning and improving the Read/Write algorithm. Finally, the proposed cause analysis and design effectiveness were verified through the CAN communication board single item test and a system equipment application test. It is expected that this study will serve as a reference for improving defense capabilities through improving the reliability of CAN communication boards and by improving the reliability of the overall electronic equipment using DPRAM.

Standardization of Bending Impact Test Methods of Sn-Ag-Cu Lead Free Solder Ball (Sn-Ag-Cu계 무연 솔더볼 접합부의 굽힘충격 시험방법 표준화)

  • Jang, Im-Nam;Park, Jai-Hyun;Ahn, Yong-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.55-61
    • /
    • 2010
  • An impact bending test method was used to evaluate the reliability for the solder joint of lead-free solder ball. In order to standardize the test method, the four point impact bending test was applied under the conditions of various frequencies and amounts of +/-amplitude respectively. Effects on the results were analysed. The optimum condition for impact bending test achieved in this study was the frequency of 10 Hz, and the amplitude of (+12/-1)~(+15/-1). 3 kinds of surface finishes Cu-OSP (Organic Solderability Preservative), ENIG (Electroless Nickel Immersion Gold), and ENEPIG (Electroless Nickel, Electroless Palladium, Immersion Gold) were used. Fracture surface showed that cracks were initiated and fractured along the intermetallic layer in the case of surface finishes of Cu-OSP and ENIG, while in the case of ENEPIG the cracks were initiated and propagated in the solder region.

Hardness Evaluation of Spot Welding Using Instrumented Indentation Technique (계장화 압입시험법을 이용한 점용접부의 경도평가)

  • Jin, Ji-Won;Kwak, Sung-Jong;Yoo, Dong-Ok;Kim, Tae-Seong;Kang, Ki-Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1081-1086
    • /
    • 2012
  • This study deals with hardness evaluation for spot welding by using an instrumented indentation technique to improve the quality of the inspection methodology. First, an instrumented indentation test and a Rockwell hardness test were performed for normal and abnormal spot welding. The hardness to indentation force-displacement curve obtained using each of the tests was compared. Furthermore, an analysis was conducted using the hardness obtained by the instrumented indentation technique. A quality control standard based on reliability was this evaluated for spot welding.

DEVELOPMENT AND PERFORMANCE VERIFICATION OF NANOSATELLITE HAUSAT-2 COMMUNICATION SUBSYSTEM (나노위성 HAUSAT-2 통신 서브시스템 개발 및 성능검증)

  • Yi Shim-Ho;Moon Byoung-Young;Na Hee-Seung;Chang Young-Keun
    • Bulletin of the Korean Space Science Society
    • /
    • 2006.04a
    • /
    • pp.125-128
    • /
    • 2006
  • Communication Subsystem of HAUSAT-2 which is 25kg class nanosatellite is designed, manufactured and tested for its performance verification at the Space System Research Laboratory (SSRL). HAUSAT-2 Communication Subsystem provides communication link for commands receiving, mission and state of health data transmission with high reliability. This paper describes design, manufacturing, test results of Engineering Model of HAUSAT-2.

  • PDF

Analysis of Material Tests for Predicting and Correcting the Shortening of Vertical Members (수직부재 축소량 예측 및 보정을 위한 재료시험 분석)

  • Park, Hee-Gon;Kwon, Hae-Won;Lee, Jin-Woo;Bae, Yeoun-Ki;Youn, Kang-Sup;Lee, Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.173-174
    • /
    • 2009
  • With the recent emergence of high rise buildings, this study was conducted in order to examine shortening, which has been used only in civil engineering structures, in such buildings. Examination of the shortening of vertical members is basically focused on deformations caused by load applied to concrete, material characteristics, etc. Shortening is analyzed through calculating parameters from the factors or characteristics of concrete, but analysis in the aspect of material tests has been somewhat unsatisfactory. Thus, this study purposed to analyze basic material test items for correcting the shortening of vertical members, namely, columns, to determine the reliability of material tests before parameter calculation for correcting shortening, and to examine the performance of material tests.

  • PDF

Characteristics of the Progressive Brittle Failure around Circular Opening by Scaled Model Test and Discrete Element Analysis (축소 모형시험과 개별 요소 해석에 의한 원형 공동 주변의 점진적 취성파괴 특성에 관한 연구)

  • Jeon Seok-Won;Park Eui-Seob;Bae Seong-Ho
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.250-263
    • /
    • 2005
  • Progressive and localized brittle failures around an excavated opening by the overstressed condition can act as a serious obstacle to ensure the stability and the economical efficiency of construction work. In this paper, the characteristics of the brittle failure around an circular opening with stress level was studied by the biaxial compressive test using sealed specimen and by the numerical simulation with $PFC^{2D}$, one of the discrete element codes. The occurring pattern and shape of the brittle failure around a circular opening monitored during the biaxial loading were well coincided with those of the stress induced failures around the excavated openings observed in the brittle rock masses. The crack development stages with stress level were evaluated by the detailed analysis on the acoustic emission event properties. The microcrack development process around a circular opening was successfully visualized by the particle flow analysis. It indicated that the scaled test had a good feasibility in understanding the mechanism of the brittle failure around an opening with a high reliability.

Evaluation of the Nonlinearity Parameter in Unbound Material for Asphalt Concrete Pavement using Field-NDT Equipment (현장 도로평가장비를 이용한 입상재료층의 비선형 재료상수 추정에 관한 연구)

  • Seo, Joo Won;Choi, Jun Seong;Kim, Soo Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.227-234
    • /
    • 2008
  • This study examines which models are more suitable for representing mechanical property of unbound materials to analyze behavior of asphalt pavement structure. Results from FWD (Falling Weight Deflectometer) test were used to apply to nonlinear elastic model. The new method which can deduct material constants of nonlinear elastic model is suggested from FWD test data rather than laboratory resilient modulus ($M_R$) test. It is confirmed that the material constants are within the common range in subbase. Test output from FWD and MDD (Multi-Depth Deflectometer) was used to verify reliability of the model. From the results of verification, this study shows that a non-linear elastic model agrees to MDD test data more than a linear elastic model does.

A Study on Architecture of Test Program based UML (UML 기반 점검 프로그램 설계 방법에 관한 연구)

  • Kim, ByoungYong;Jang, JungSu;Ban, ChangBong;Lee, HyoJong;Yang, SeungYul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.217-230
    • /
    • 2012
  • This paper propose interacting test programming methods between test equipment and hardware unit to verify function and performance of the hardware unit under test. Proposed test program can minimizes the risk of failures when the unit is mounted on the aircraft by testing and verifying the unit under the worst stress condition. Also, Object oriented design using UML make it easy to apply in other equipments. Test program consists of architecture package and hardware package. Architecture package is in a role for system management, log analysis, message receiving and message analysis. Messages that are used by system management define messages for testing and defined messages is sent and received to test equipment through Ethernet. Hardware package is in a role for hardware management that is needed to be tested and is related to a system. Hardware to be tested is divided into internal test and transmission test. Internal test inspects hardware itself and reports the test results to the test equipment. Transmission test inspects communication device by sending or receiving data. All kinds of test is done in the worst condition of the test unit executing in parallel. Each device is tested at least 482 times and at most 15,003 times about one hour. Test program is utilized in hardware reliability test like as environmental test or EMI test.