• Title/Summary/Keyword: 시험렌즈

Search Result 89, Processing Time 0.03 seconds

The Evaluation of Reliability for the Combined Refractive Power of Overlapping Trial Lenses (중첩된 시험렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.263-276
    • /
    • 2015
  • Purpose: The current study aimed to evaluate the reliability for the combined refractive power when a spherical lens and a cylindrical lens were overlapped in a trial frame. Methods: The refractive powers, central thickness and peripheral thickness of spherical trial lenses and cylindrical lenses with negative power were measured. The combined refractive power of the spherical and cylindrical lenses was measured by auto lens meter. Measurement was repeated by changing the insertion order, and their results were further compared with the calculated combined refractive power. Results: There was no correlation between the variation of central and peripheral thickness in trial lenses and that of the lens power. Among 79 trial lenses, 3 trial lenses wasn't met the international standard. The refractive power calculated by Gullstrand's formula that could compensate vertex distance had smaller difference with the estimated power when compared with that calculated by thin lens formula however, it was significantly different from the estimated power. The refractive powers were generally apparent regardless of the insertion order of a spherical lens and a cylindrical lens: thin lens formula > actual measurements > Gullstrand's formula. The error was only found in cylindrical power calculated by Gullstrand's formula when inserted a spherical lens inside and a cylindrical lens outside however, the error was found in both of cylindrical and spherical powers calculated by Gullstrand's formula when inserted as a opposite order. By comparing actual measurements of equivalent spherical power, the accuracy was higher and the possibility of over-correction was lower when inserted a spherical lens inside and a cylindrical lens outside. Conclusions: From the results, those were revealed that the combined refractive power is influenced by the factors other than the vertex distance and the refractive power varies in accordance with the insertion order of a spherical lens and a cylindrical lens. Thus, it can be suggested that the establishment of standard for these is neccesaty.

Determination of the Decenter Position of a Test Lens in a Six-Sided Prism Lens Lensmeter (6면 프리즘 렌즈가 장착된 Lensmeter에서 시험 렌즈의 편심 위치 계산)

  • Lin, Maria;Park, Jong-Dae;Jo, Chang-Ho;Kim, Hyeon-Gyu
    • The Journal of Natural Sciences
    • /
    • v.16 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • We have developed an algorithm to determine the position from the image points in a lensmeter with 6-sided prism lens. The positions of the image points which are formed by six prisms depends on the decenter position of a test lens and can be calculated by skew ray tracing. The optical characteristics of the lens meter was analyzed using the Code V program and the positions of the image points was expressed as a function of the decenter position of the test lens. By minimizing the expectation error, we can determine the decenter position position of a test lens from the image positions.

  • PDF

A Study on the Reliability of Corrected Diopter according to Subjective refraction instrument (자각식굴절검사기기에 따른 교정굴절력의 신뢰도에 관한 연구)

  • Lee, Hark-Jun;Kim, Jung-Hee;Ryu, Kyung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.281-286
    • /
    • 2010
  • Purpose: This research provided basic data for refraction by comparing the corrected diopter of trial lens and phoropter. Methods: We compared the corrected diopter of trial lens and phoropter, and analyzed statistical significance and relations of the spherical lens corrected diopter and cylindrical lens corrected diopter according to the types (trial lens and phoropter) of subjective refractive instruments. Also we analyzed statistical significance and relations between cylindrical lens corrected diopter at the astigmatism and the types (trial lens and phoropter) of subjective refractory instruments. Results: When we measured the corrected diopter of simple myopia, the mean value for corrected diopter was S-2.74D using the trial lens and S-2.65D using the phoropter. So the corrected diopter was 0.09D smaller when measured by phoropter. The degree of astigmatism was measured C-0.81D using the trial lens and C-0.77D using the phoropter which showed that the measured value was 0.04D smaller using the phoropter. On correlation analysis between the refractive instruments (trial lens and phoropter) and the corrected diopter, there was significant (p<0.01) strong correlation between refractory machine and corrected spherical diopter (r=0.996) and the correlation between refractory machine and corrected cylindrical diopter was r=0.986 and was also significant (p<0.01). Conclusions: The use of phoropter than trial lens was more desirable when performing refraction on high myopia (simple refractive error, high astigmatism), and when using trial lens, you should consider the vertex distance and the gap between overlapped lenses before prescription.

The Actual Management State of Trial Contact Lenses and Lens Care Products in Local Optical Shops (안경원의 시험착용 콘택트렌즈 및 관리용품 관리 실태)

  • Park, Mijung;Lee, Unjung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.391-401
    • /
    • 2011
  • Purpose: In the present study, the actual management state of trial contact lenses and lens care products in local optical shops was surveyed and analyzed to reduce the risk of lens complication possibly induced by neglecting lens care. Methods: The feeling of contact lens wearers during the wear of trial contact lenses was surveyed. Futhermore, the actual management state of trial contact lenses such as cosmetic lens and RGP lens and lens care products was also investigated by surveying opticians who trade contact lenses in local optical shops. Results: It was found that consumers trusted the sanitary conditions of the lens since trial cosmetic contact lens and RGP lens were cleaned before and after trails by over 98% of opticians in local optical shops. For trial cosmetic lens, cleaning with normal saline, multipurpose solution for soft lens and combination of saline and multipurpose solution were 38.5%, 40.5% and 21%, respectively, before trials. After trials, cosmetic lenses were cleaned with normal saline, multipurpose solution for soft lens and a combination of saline and multipurpose solution were 13%, 75%, and 12%, respectively. On the other hand, cleaning with normal saline, multipurpose solution for RGP lens and combination of saline and multipurpose solution were 28.5%, 38.5% and 33%, respectively, before trying trial RGP lens. After trials, RGP lenses were cleaned with normal saline, multipurpose solution for RGP lens and a combination of saline and multipurpose solution were 2.5%, 70%, and 27.5%, respectively, indicating that relatively many opticians followed the lens cleaning regimen. In local optical shops, the cleaning trial cosmetic lens was mainly conducted at every 10 days or a month and the washing cycle of cosmetic lens case was in a month or 2~3 months. The cleaning interval of trial RGP lens was primarily in a month or 2~3 months. For those lens cases, more than 75% of opticians washed them with a surfactant and then rinsed with cold water. The storing periods of lens care products were primarily in a week for saline and in a month and 2~3 months indicating that storing period of lens care products was relatively well-kept in local optical shops. Conclusions: It is thought that the concern about any microbial infection is not that high since trial contact lenses and lens care products were generally well-managed by opticians in local optical shops from the results above. However, better public eye health and better public confidence in opticians may be possible if further strengthen in avoidance of lens cleaning with saline, keep of cleaning cycles within 2 weeks and rinsing of lens cases with hot water happens.

The Evaluation on the frequency Characteristics of the Optical Glass Lens by Resonant Ultrasound Spectroscopy (RUS법에 의한 광학기기용 렌즈의 주파수 특성평가)

  • Yang, In-Young;Kim, Seung-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.127-132
    • /
    • 2005
  • The optical glass lens is required high dimensional precision such as the lack of defect. In this paper, we examined the detectable defect by using the resonant ultrasound spectroscopy(RUS). The RUS is the measurement system which is to excite the specimen and to inspect the differences of resonant frequency pattern between acceptable specimen and specimen which has some defects. In this paper, for nondestructive evaluation by using RUS, we measured the resonant frequency of each specimen which is spherical and aspherical glass lens. With the results, we knew the polishing processing degree of spherical glass lens by the measured resonant frequency and could evaluate the characteristic of aspherical glass lens about some flaws.

The Study about Measuring Method in Radius of Eyeglasses Lens Curvature by using Keratometer (각막곡률계를 이용한 안경렌즈 곡률반경 측정방법에 관한 연구)

  • Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.127-133
    • /
    • 2012
  • Perpose: The aim of this study is to investigate the measuring method in radius of eyeglasses lens curvature by using keratometer in noncontact method. Methods: A trial lens for vision test in diopter range from -9.00 D to -11.50 D were attached in front part of keratometer, after that we set eyeglasses lens at the place where eyeglasses lens is apart about 25 cm from front position of keratometer. We measured the radius of curvature from observation of clear mire image while the position of eyeglasses lens is changed in a small quantity. After that, we made some formulas for compensation of radius of curvature by using spherometer. Results: The radius of curvature was successfully measured by keratometer with trial lens in front part of it. The measured radius of curvature was changed to compensation value using spherometer data, and the 5 kind of linear equation to make compensation value was made. Any kind of lenses measured by using keratometer that trial lens was attached in front part of it, after that it was confirmed that the result of calculation from line equation is exact in error ratio below 3.5%. Conclusions: It was confirmed that radius of eyeglasses lens curvature can be measured by using keratometer by noncontact method, and the accuracy is higher than "lens measure".

Design and Fabrication of Real-time Lens Testing System (실시간 렌즈 성능평가장치 설계 및 제작)

  • 이윤우;조현모;이인원;홍경희;이환규
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • 복사기. 팩스 렌즈 등 대향생산되는 광학계를 실시간에 성능평가하기 위하여 5개의 십자형 슬릿 물체와 3개의 2차원 CCD를 상분석장치로 사용한 자동평가장치를 개발하였다. 시험렌즈의 사양에 따라 물체와 렌즈, 그리고 상분석장치를 이동시키는 자동정렬장치를 제작하였으며 슬릿의 수직 및 수평방향 선분포 함수를 CCD에 의햐여 동시에 측정하였다. 그리고 렌즈의 축상 및 비축상 MTF와 배율, 편심, 그리고 회전위치에 따른 최적방향 등을 자동으로 실시간에 측정할 수 있었다.

  • PDF

Inhomogeneous amplitude modulation effects on the MTF of binocular objective (비균일 진폭변조가 쌍안경 대물경의 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.102-106
    • /
    • 1999
  • In this study, inhomogeneous amplitude modulation effects on the imaging performance a lens system are expermentally investigated by measuring the diffraction OTF. The lens under the test is a binocular objective made in Korea. Inhomogeneous amplitude modulation is carried out by positioning the modulator cross contacted to the lens under test which is illuminated by collimated light beam. The aberration characteristics of the lens under test are examined by caculating the ray-fan through finite ray tracing. The MTFs of the lens illuminated by the homogeneous and inhomogeneous light beam are measured on the Gaussian image plane and compared with one another.

  • PDF

Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter (자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2015
  • Purpose: To evaluate the reliability of refractive power by comparing the marked refractive power in an automatic phoropter and actually measured spherical/cylindrical refractive power. Methods: Actual refractive power of minus spherical lens and cylindrical lens in an automatic phoropter was measured by a manual lensmeter and compared with the accuracy of marked refractive power. Furthermore, combined refractive power and spherical equivalent refractive power of two overlapped lenses were compared and evaluated with the refractive power of trial lens. Results: An error of 0.125 D and more against the marked degree was observed in 70.6% of spherical refractive power of spherical lens which is built in phoropter, and the higher error was shown with increasing refractive power. Single cylindrical refractive power of cylindrical lens is almost equivalent to the marked degree. Combined spherical refractive power was equivalent to spherical refractive power of single lens when spherical lens and cylindrical lens were overlapped in a phoropter. Thus, there was no change in spherical refractive power by lens overlapping. However, there was a great difference, which suggest the effect induced by overlapping between cylindrical refractive power and the marked degree when spherical lens and cylindrical lens were overlapped. Spherical equivalent refractive power measured by using a phoropter was lower than that estimated by trial glasses frame and marked degree. The difference was bigger with higher refractive power. Conclusions: When assessment of visual acuity is made by using an automatic phoropter for high myopes or myopic astigmatism, some difference against the marked degree may be produced and they may be overcorrected which suggests that improvement is required.

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.