• Title/Summary/Keyword: 시험결과 분석

Search Result 8,418, Processing Time 0.042 seconds

A Analysis on the Result of CE/CS Test on the KOMPSAT-I ETB (아리랑1호 위성 ETB의 전도성 전자파 환경 시험결과 분석)

  • 임성빈;천용식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.184-192
    • /
    • 2001
  • In this paper, we analyze the result of the conduced emission and susceptibility tests performed on the KOMPSAT-I ETB Platform. The ETB platform consists of the EM (Engineering Model) boxes developed to perform the electrical functional test. During the conducted emission test, we measured the instant waveform in time domain when each switch was turn on, and spectrum of the noise in the frequency range of 10 Hz up to100 MHz fur the steady state of the ETB. During the conducted susceptibility test, no malfunction and no serious damage of the electronic box were observed when a simulated noise waveform was applied to the DC power bus. The simulated waveform was obtained by adding the 6 dB-system margin to the worst case waveform measured from the conducted emission. This test was performed as co-development of the KOMPSAT-I with TRW in USA.

  • PDF

A Study on the Takeoff and Landing Performance of Aircraft (경비행기의 이착륙 성능에 관한 연구)

  • Kim, J.H.;Hwang, M.S.;Lee, J.M.;Kim, C.Y.;Jin, I.H.;Jang, U.J.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.3 no.1
    • /
    • pp.97-105
    • /
    • 1995
  • 본 연구는 창공-91 항공기의 비행 시험의 일환으로 수행된 것으로, 항공기의 이 착륙 성능 측정을 위한 비행 시험의 절차와 사용된 방법, 자료 처리 절차 그리고 비행 시험 결과에 대해 기술하였다. 본 비행 시험은 FAR 부속서인 Advisory Circular 23-8A 의 비행 시험 절차에 따라 수행되었으며, 측정된 자료를 분석한 결과 설계시에 결정된 창공-91의 성능 자료를 만족함을 보였다.

  • PDF

A Study on Vibration Analysis and Test of Satellite Solar Panel Structure (위성용 태양전지판 구조물의 진동해석 및 시험에 관한 연구)

  • 문상무;이주진;이상설;최익현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.73-80
    • /
    • 1995
  • 본 연구에서는 범용 구조해석 프로그램인 NASTRAN을 이용하여 실위성용 복합소재 태양전지판 구조물의 유한요소 모델링을 통해 진동특성에 대한 해석을 수행하였으며, 진동 특성 측정용 치구를 제작하고, 측정센서의 질량이 미치는 영향을 해석적인 방법으로 분석하였으며, 진동특성 측정시험을 수행하였다. 최종적으로 해석결과를 시험결과와 비교하므로써 태양전지판 구조물의 진동특성 시험방법을 정립하고 모델링기법을 검증하였다.

  • PDF

Systematic Quality Assurance Activity for TDX-10 ISDN Switching System (TDX-10 ISDN 시스템의 시험 및 평가분석 체계화에 따른 품질보증 활동)

  • Lee, Haeryong;Jeong, Taegwon
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.1
    • /
    • pp.127-141
    • /
    • 1995
  • 대용량 ISDN(Integrated Services Digital Network)용 전전자 교환기 TDX-10 연구개발 사업의 궁극적 목적은 미래 통신망이 요구하는 다양한 음성 및 비음성 정보통신 서비스를 제공하고 정보의 교환, 가공, 축적 및 처리에 고도의 융통성을 부여할 수 있는 국내표준 전전자 교환기를 개발하여 통신투자의 경제적 통신운영기술 자립화를 달성하는데 있다. 현재 대용량 전전자 교환기인 TDX-10 ISDN의 상용화 단계의 마무리 업무가 진행중이며, 통신서비스의 다양화, 광대역화, 고속화를 위한 광대역통신망의 주축이 되는 ATM교환기가 개발중에 있다. 본 고에서는 TDX-10 ISDN 시스템개발단계에서 구현된 시스템 시험수행 과정 및 평가작업을 토대로한 체계적이며 전략적인 품질보증 활동에 관해 기술하였으며, 신뢰성 있는 시험결과를 도출할 수 있는 다양한 시험관리 기법과 그 결과를 분석하고 차후 시험 및 보완작업을 위한 제반 활동체계가 소개된다.

  • PDF

Multiple Slug and Pumping Tests for Quality Enhancement of Hydraulic Parameter Estimates (순간수위변화 및 양수시험을 통한 수리상수 추정의 문제점 분석)

  • 이진용;이강근;정형재;배광옥
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.14-22
    • /
    • 1999
  • Slug and pumping tests have been widely used to obtain hydraulic parameter estimates in the field. Although a variety of sources of error and uncertainty can be involved in the course of the test performance and data analysis, serious considerations on these sources are often neglected. In this study these various sources of error and uncertainty are analyzed or discussed using repeated slug and pumping test data and some guide lines are suggested to improve quality of parameter estimates from the slug and pumping tests.

  • PDF

The Characteristics of Axial Bearing Capacity for the High Strength H-pile (고강도 H말뚝의 연직 지지력 특성)

  • 신방웅;여병철
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.2
    • /
    • pp.135-143
    • /
    • 2000
  • 고강도 H말뚝은 다른 말뚝에 비해 관입성이 우수하며, 경제적으로 시공이 가능하여 도로공사 및 건축공사의 기초말뚝으로 광범위하게 전세계적으로 사용되어지고 있다. 따라서 본 논문에서는 고강도 H말뚝, 강관말뚝 및 PHC 말뚝에 정재하시험과 동재하시험을 실시하여 허용지지력을 비교 분석하였으며, 각각의 말뚝에 대한 동재하시험을 통해 시간경과효과를 평가하였다. 정재하시험과 동재하시험을 비교 분석한 결과 하중-침하곡선이 유사한 것으로 조사되었다. 또한 고강도 H말뚝, 강관 말뚝, PHC 말뚝이 지반내에 향타되었을 때의 허용지지력은 시간이 경과함에 따라 증가하는 것으로 평가되었다. 재하시험 결과 시간경과효과로 인해 지반의 허용지지력이 상승됨을 알 수 있어 앞으로 기초말뚝 설계시 참고자료로 활용할 수 있을 것으로 사료된다.

  • PDF

Study on Thermal Vacuum Test Result of DCAMP by the Analysis of Derating & Gain Control (디지털중계기의 부하경감 및 이득조정기능 분석을 통한 열진공시험결과 성능분석)

  • Jin, Byoung-Il;Ko, Hyun-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.1
    • /
    • pp.72-78
    • /
    • 2015
  • Recently, the usage of the satellite is increased more and more in the areas that are communication, weather, marine, optical, radar etc. The functions of the Satellite are evolving from passive transponder to active transponder by the developing of a technology. Advanced countries in satellites install the DCAMP for increase of bandwidth efficiency, improvement of QoS by interference rejection. DCAMP includes many digital components in order to implement functions. Thus, these kinds of active transponders consume much more power compared to passive transponder and then increase the heat. In this paper, we discuss the TVAC test result of DCAMP in EQM(Engineering Qualification Model) level. The paper shows the test results of digital gain control in order to verify DCAMP status under the TVAC test. In addition, the temperature and heat condition of main components from viewpoint of derating will be treated through the official environment test for qualification.

Interlaboratory Validation Study of In Vitro Alternatives to the Draize Eye Irritation Test : HET-CAM Test and Cytotoxicity Test for 20 Cosmetic Ingredients

  • Lee, Ho;Kim, Ju-Hyun;Hong, Jin-Cheon;Kim, Gi-Mun;Park, Mun-Eok;Ryu, Chang-Seok;Jeong, Min-Seok;Kim, Jong-Il
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.2
    • /
    • pp.129-138
    • /
    • 1999
  • 피부 전용 제재 개발을 위해 요구되는 동물 대체 시험법 중 가장 적극적으로 연구가 행하여지곤 실제 실용화가 예상되는 것은 안점막 자극 시험으로 지금까지 여러 가지 방법이 개발되었지만 그 중 계란 유정란의 응모요막(CAM)을 이용한 방법이 현재 가장 활발히 진행되고 있다. 이 방법이 일부 국가에서 이미 안점막 자극 시험 동물 대체 시험법으로 공인되었으며 현재까지도 validation 연구를 활발히 진행하고 있다. 본 연구에서도 국내에 적합한 안점막 자극 시험 동물 대체 시험법의 공인 시험법 개발 및 validation study를 목표로 계란 유정란의 응모요막을 이용한 방법 중 HET-CAM 방법을 시행하였으며 안점막 동물 대체 시험법으로 확립하고자 하였다. 틴ET-CAM 방법의 보완을 위해 배양된 세포를 통해 자극도를 측정할 수 있는 방법인 Cytotoxicity test를 도입하여 시행하였으며 두 방법의 data들을 분석하여 validation study를 수행하였다. 국내 유수의 6개 장업사가 본 연구에 참가하여 20가지의 화장품 전용제재를 대상으로 1차, 2차 validation study 를 진행하였다. HET-CAM test, Draize eye irritation test, Cytotoxicity test 측정 결과 HET-CAM 의 “Q” 수치는 대부분 강자극 수치인 2 이상이었고 10% sodium hydroxide가 가장 높은 수치를 보였으며 Tween 20(sorbitanpolyoxyethylene monolaurate) 100%가 가장 낮은 수치를 보였다. In vi패의 경우 10% sodium hydroxide가 가장 높은 수치를 보였으며 30군 propylene glycol 이 가장 낮은 자극수치를 보였다. HET-CAM test 와 Draize eye irritation test, Cytotoxicity test 간의 상관성 분석은 linear correlation coefficient 와 rank correlation coefficient를 구하여 비교하였으며 6개 장업사(A-F)의 실험실에서의 HET-CAM test 결과를 취합하여 각각 두 실험실간의 상관관계(linear correlation)를 분석하였다. Linear correlation coefficient 분석 결과를 보면 전반적으로 상관관계가 0.589 - 0.954의 범위였으며, 특히 A사와 B사 사이의 경우 0.954이었으며, E사와 D사 사이의 경우 0.942로 높은 상관관계를 보였다. 그 외에도 A사와 D사 사이의 경우(0.589)와 B사와 D사 사이의 경우(0.638)를 제외하고는 대체로 높은 상관관계를 나타내었다.

  • PDF

솔잎 증류액의 생리활성에 탐색에 관한 연구

  • 이효진;김수현;최승필;이득식;함승시
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.136.2-136
    • /
    • 2003
  • 솔잎은 예로부터 민간에서 약용으로 사용되어 간장질환, 비뇨생식기질환, 위장질환, 신경계질환, 순환기질환 및 피부질환 등에 효과가 있다고 알려져 있고 식용으로도 널리 이용하여온 천연식물 자원중의 하나이다. 따라서 본 연구에서는 솔잎 증류액을 가지고 솔잎이 갖는 향기 성분에 대한 분석, 음용수 적합성 시험을 행하였으며, 생리활성 효과를 알아보고자 DPPH 라디칼 소거능 시험, 항돌연변이원성 시험, 세포독성 시험, 유전독성 억제시험을 실시하였다. 실험결과, 향기 성분과 음용수 분석 시험에서는 음용수로 부적합한 성분이 검출되지 않았으며, DPPH 라디칼 소거능 시험에서 RC$_{50}$이 69.9${\mu}\ell$로 높은 항산화 활성을 나타내었다. 또한 항돌연변이원성 시험에서 Salmonella typhimurium TA100 균주에 대하여 시료 농도 200${\mu}\ell$/plate에서 80% 이상의 억제율을 보였다. 세포독성시험 결과, 시료농도 50${\mu}\ell$/well에서 위암세포인 AGS, 간암세포인 HepG2 모두에서 90% 이상의 높은 억제율을 보였다. 그리고 생체내 시험인 유전독성 시험에서는 시료 200${\mu}\ell$/kg에서 72.4%의 비교적 높은 유전독성 억제 효과를 나타내어 기능성 식품의 소재로 사용이 가능 할 것으로 사료된다.

  • PDF

KAERI 폐 카운터를 이용한 LLNL 팬텀과 JAERI 팬텀과의 비교

  • 이종일;이태영;김종수;장시영
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.600-605
    • /
    • 1998
  • 체내방사능 측정시스템의 교정인자는 측정결과에 주요한 요인으로 작용한다. 교정인자는 특정 집단으로부터 표준체위와 표준장기를 도출, 이를 기초로 하여 제작한 펜텀으로부터 구하는 것이 일반적인 방법이다. 그러나 팬텀의 기하학적 구조 및 내부장기의 형상은 특정 집단에 따라 다르므로 이로 인한 측정오차가 발생할 수 있다. 따라서 본 연구에서는 북아메리카 성인남성의 표준자료에 근거하여 제작된 LLNL 팬텀과 일본성인 남성의 표준자료에 근거하여 제작된 JAERI 팬텀을 한국원자럭연구소 폐 카운터를 이용하여 상호비교.분석하였다. 이와 함께 LLNL 팬텀으로 교정된 폐 카운터의 성능시험을 JAERI 팬텀으로 DOELAP 성능시험범주 I, II, III 및 IV에 대해 수행하여 편텀의 구조 및 형상으로부터 발생하는 측정오차를 분석하였다. 비교.분석결과 1.7 cm ~ 3.7 cm 근육등가 가슴벽두께 범위내에서 JAERI 팬텀에 의한 교정인자가 전반적으로 LLNL 팬텀의 것보다 다소 높은 수치를 보였으나 허용수준이었고, 성능시험결과 상대편중은 DOELAP 성능 용인 기준을 만족하였다. 결국 두 팬텀간의 측정오차는 측정 및 체내피폭선량 평가시 수반되는 오차와 비교해 보면 그다지 크지 않은 것으로 결론지울 수 있다. 따라서 LLNL 펜텀으로부터 구한 교정인자를 국내 성인남성의 일상 모니터링에 사용할 경우 측정결과가 다소 과대평가되기는 하나 허용수준으로서 큰 문제가 없는 것으로 나타났다.