• Title/Summary/Keyword: 시리얼포트

Search Result 25, Processing Time 0.042 seconds

Analysis of Data Transmission Rate and Power Consumption in Zigbee Based Electrocardiography (지그비 기반 심전계의 데이터 전송률과 소비 전력 분석)

  • Kim, Nam-Jin;Hong, Joo-Hyun;Lee, Tae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.96-104
    • /
    • 2006
  • In this study, data transmission ratio and power consumption issues of Zigbee based sensor module and personal digital assistant(PDA) were addressed to develop ECG telemetry device. PDA processes the data transmitted through serial port using non-blocking method. The transmission rate was dependent on the packet structure. It was 300 ECG samples/sec, when each packet was composed of 2 ECG data and 3-axial acceleration vector. Using two AAA batteries in series, operating time of the wireless sensor module was above 28 hours in average. Power consumption of PDA was dependent on screen ON/OFF condition and serial port usage. In this application, operating time of PDA was 5 hours in average. In conclusion, there was no problem in the power consumption of wireless sensor module and transmission rate, when the developed device was used as 24 hour Holter device. But, PDA has the problem of power consumption, which should be solved.

  • PDF

Real Time Speaker Close-Up and Tracking System Using the Lip Varying Informations (입술 움직임 변화량을 이용한 실시간 화자의 클로즈업 및 트레킹 시스템 구현)

  • 양운모;장언동;윤태승;곽내정;안재형
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2002.05d
    • /
    • pp.547-552
    • /
    • 2002
  • 본 논문에서는 다수의 사람이 존재하는 입력영상에서 입술 움직임 정보를 이용한 실시간 화자의 클로즈업(close-up) 시스템을 구현한다. 칼라 CCD 카메라를 통해 입력되는 동영상에서 화자를 검출한 후 입술 움직임 정보를 이용하여 다른 한 대의 카메라로 화자를 클로즈업한다. 구현된 시스템은 얼굴색 정보와 형태 정보를 이용하여 각 사람의 얼굴 및 입술 영역을 검출한 후, 입술 영역 변화량을 이용하여 화자를 검출한다. 검출된 화자를 클로즈업하기 위하여 PTZ(Pan/Tilt/Zoom) 카메라를 사용하였으며, RS-232C 시리얼 포트를 이용하여 카메라를 제어한다. 실험결과 3인 이상의 입력 동영상에서 정확하게 화자를 검출할 수 있으며, 움직이는 화자의 얼굴 트레킹이 가능하다.

  • PDF

Porting of Z-Stack and Implementation of UART on the TI CC2530 (TI CC2530 상의 Z-Stack 이식 및 UART 구현)

  • Kim, Byungsoon
    • Journal of Digital Contents Society
    • /
    • v.13 no.4
    • /
    • pp.525-530
    • /
    • 2012
  • Wireless sensor networks consist of resource constraint devices which typically send data measured by sensors attached to the end devices towards a coordinator. One of the best solution for wireless sensor networks is ZigBee, where it is wireless standard introduced for low power, low cost wireless communication with moderate data rates. In this paper, we present porting of Z-Stack and implementation of UART on the TI CC2530. We show that our implemented board works correctly in terms of transmitting and receiving data via serial port.

The Development of a Machine-Parts Production Management System Based on XML for Productivity Improvement (생산성 증대를 위한 XML 기반 기계부품 생산관리시스템 개발)

  • Oh Am-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.8
    • /
    • pp.1851-1858
    • /
    • 2004
  • The goal of this paper is to develop a production management system based on XML that exclusively applies to a production line of machine-parts. This paper aims to develop the related management modules and integrate them into the production management system based on XML technology. In terms of the implementation of the client/server database module, it develops the GUI application program that supports the communication between the subsystem that controls machine-parts and the server-side database. By developing the RPC emulator, the system remotely executes server module in the client GUI module. By developing the integration control module that integrates the independently executed modules, it controls the production management system that works as a single organic management system and by developing the POP system, it builds the information system of machine-parts performance records. This information system collects performance data through the serial port of the sensor attached to the machine-parts manufacturing machine, analyzes these data and display them in the GUI fashion, and immediately reflects them in production planning. And also it develops production management system based on XML by using XML technology.

Vibrotactile Glove Mouse (진동촉각 글러브 마우스)

  • Park, Jun-Hyung;Jeong, Ju-Seok;Jang, Tae-Jeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.741-744
    • /
    • 2009
  • In this paper, We introduce the glove mouse using a Gyroscope, acceleration sensor, Pin-type Viboratctile Display Device and USB HID. The device recognize a user's wrist by Gyroscope and acceleration sensor in the glove and transmit the data to USB dongle which is recognized the manufactured mouse by Blutooth. Also, using a special application, We transmit the tactile information to user through the Pin-type Vibrotactile Display. We implement wearable system in the glove except USB device. If user want to use general spatial mouse, we recognize mouse USB dongle only without another application. If user want to feel the tactile sensationn, we can use by connecting PC serial communication port to USB dongle.

  • PDF

Analysis Method of Signal Integrity for Mobile Display Circuit Modules (모바일 디스플레이 회로 모듈의 시그널 인티그리티 해석 기법)

  • Lee, Yong-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.64-69
    • /
    • 2009
  • This paper addresses the simulation methodology of signal integrity and power integrity for mobile display modules. The proposed technique can be applied to analyse a circuit module which consist of connector, FPCB and driver ICs. The recent demand of serial interconnection technology in the mobile display industry needs delicate impedance control of signal and power traces to prohibit system malfunctioning and to reduce electromagnetic field radiation. Based on the S-parameter and Z-parameter analysis, we analyse the correlation between frequency-domain and time-domain measurements. With multi-port macros, signal integrity can be included in power integrity analysis in time domain.

Real Time Speaker Close-Up System using The Lip Motion Informations (입술 움직임 정보를 이용한 실시간 화자 클로즈업 시스템 구현)

  • 권혁봉;장언동;윤태승;안재형
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.6
    • /
    • pp.510-517
    • /
    • 2001
  • In this paper, we implement a real time speaker close-up system using lip motion information from input images having some people. After detecting a speaker from input moving pictures through one color CCD camera, the other camera closes up the speaker by using lip motion information. The implemented system detects a face and lip area of each person by means of a facial color and a morphological information, and then finds out a speaker by using lip area variation. A PTZ(Pan/Tilt/Zoom) camera is used in order to close up the detected speaker and it is controlled by RS-232C serial port. Consequently, we can exactly detect a speaker in input moving pictures including more than three people.

  • PDF

Development of remote monitoring system based on wire and wireless internet Environment (유.무선 인터넷 환경에 연동한 원격 감시시스템 개발)

  • 박상국
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.557-560
    • /
    • 2004
  • In this paper, wireless internet services are combined with conventional wire internet service system. These system support that instrument manager can be access his instrument by use personal mobile devices and instrument manager can be take emergency action by use mobile devices. for this, error signal of local instruments are transmitted to the serial port of local server through Rf wireless communication channel. Also, The image of local instruments are transmitted to the web monitoring screen of main server. Network Camera System Supports remote monitoring functions. The interfacing of nam server with external user are possible through the mobile devices.

  • PDF

A Study on the Tele-Controller System of Navigational Aids Using CDMA Communication (CDMA 통신을 이용한 항로표지의 원격관리시스템에 관한 연구)

  • Jeon, Joong-Sung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1254-1260
    • /
    • 2009
  • CDMA tele-Controller system is designed with a low power consumption 8 bit microcontroller, ATmega 2560. ATmega 2560 microcontroller consists of 4 UART (Universal asynchronous receiver/transmitter) ports, 4 kbytes EEPROM, 256 kbytes flash memory, 4 kbytes SRAM. 4 URAT is used for CDMA modem, communication for GPS module, EEPROM is used for saving a configuration for program running, a flash memory of 256 kbytes is used for storing a F/W(Firm Ware), and SRAM is used for stack, storing memory of global variables while program running. We have tested the communication distance between the coast station and sea by the fabricated control board using 800 MHz CDMA modem and GPS module, which is building for the navigational aid management system by remote control. As a results, the receiving signal strength is above -80 dBm, and then the characteristics of the control board implemented more than 10 km in the distance of the communication.

Development of Multi-channels NMEA0183 Indicator System (다채널 NMEA0183 인디케이트 시스템 개발)

  • Kim, Gwan-Hyung;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2327-2332
    • /
    • 2011
  • Recently, the increase of loading amount on cargo ships due to the automation of loading process results in much complex ship operation. For this reason, NMEA-0183 based on RS-422,485 and NMEA-2000 based on CAN communication methods have been usually used as a standardized method in the marin electric interfacing equipments. In this paper, a general NMEA-0183 protocol was designed to support 7-channel NMEA-0183 serial communication data, which can receive 3-channel 16 bits ADC and 2-channel pulse using SPI(Serial Peripheral Interface). In particular, this method was designed for ship communication requires 7 important factors. Also in this study, using the minimization of the proposed method and realizing the monitoring system based on PC, the effectiveness of multichannel indicator system was proposed.