• Title/Summary/Keyword: 시료의 대표성

Search Result 288, Processing Time 0.031 seconds

A Study on the Statistical Representativeness of Samples taken from Radioactive Soil (방사성 토양폐기물 시료의 통계적 대표성에 관한 연구)

  • Cho Han-Seok;Kim T.K.;Lee K.M.;Ahn S.J.;Shon J.S.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.151-157
    • /
    • 2005
  • For the treatment of regulatory clearance of the soils, a procedure for the radionuclides and radioactivity concentration analysis is under development. A strategy for soil sampling including random sampling after homogenization and standardization was set up. Statistical representativeness is considered for not only sampling strategy but also sample size. In this study, designed sample size was designed with confidence interval and error bound of soil using the pilot samples which were taken following the sampling strategy.

  • PDF

경수로 원자로 냉각재 CRUD 대표시료 채취 기술에 관한 고찰

  • Kim, Min-Jae;Kim, Jong-Bin;Gang, Deok-Won;Park, Jong-Seok
    • 대한방사선방어학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.254-255
    • /
    • 2009
  • 국내 경수로 원전의 경우, 원전의 효율적, 경제적 운영차원에서 장주기 운전으로 패턴을 바뀌면서 핵연료봉 표면상에 크러드(crud)의 침적량은 점점 증가하는 경향을 나타내고 있다. 이러한 경향은 원자로의 출력 제어와 직결되면서 이에 대한 문제 해결을 위한 대표성이 있는 시료의 채취와 재현성이 있는 부식 생성물의 측정이 요구되어져 왔다. 원자로 계통 내에서 부식생성물의 농도변화에 대한 평가, 특히 입자농도가 증가되어지면 축방향 출력편차(Axial Offset Anomaly, AOA)가 발생될 수 있는 위험에 노출되거나, 핵연료 교체를 위해 발전소 정지시(shut down) 부식생성물의 방출이 급격히 증가되는 것으로 나타났다. 특히 입자성을 띤 물질은 존재의 특성상 이들 물질에 대한 대표시료의 채취가 어려울 뿐 아니라 grab 채취로 인해, 분석결과에 대한 재현성이 낮으며 계통 선량율의 제어와 작업자 피폭관리에 많은 어려움이 뒤따르고 있어 선진 원전 운영국에서는 앞 다투어 대표시료를 채취 할 수 있는 capillary sampling 법이나 integrated sampling법을 적용해 오고 있다. 본 논문에서는 국내 경수로 원전에서 일반적으로 사용하고 있는 grab sampling 법에 대한 문제점 파악과 해외 원전에서 사용 중인 capillary sampling 법의 국내 적용 가능성에 대해 살펴보았다.

  • PDF

A Study on the Toxic Gases Released from Fire Retardant Finishing Materials (가스검지관법에 의한 방염시료의 연소가스 독성평가)

  • Lee, Hae Pyeong;Park, Young Ju;Lim, Suk Hwan;Kim, Jung In
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.195-195
    • /
    • 2011
  • 본 연구는 방염성능시험에 의한 필름 및 도료처리 시료를 대상으로 화재 시 발생하는 연소가스 중의 독성에 대하여 NES 713 방법에 의해 분석하고, 독성지수를 확인함으로써 연소 시 인체에 미치는 영향을 간접적으로 확인해 보고자 하였다. 기존 방염제품 중 필름과 도료처리 그리고 도료처리 후 기간이 경과한 시료의 3가지로 실험군을 구분하였으며, NES 713 방법으로 연소가스를 분석하고 독성지수를 평가하였으며, 추가로 기존의 국내 노출기준과의 비교를 수행하였으며, 국내 NES 713 방법을 활용한 선행연구들을 참조하였다. 발암가능 추정물질인 아크릴로니트릴은 총 18개의 시료에서 검출되었으며, 포름알데히드는 9개의 시료에서 검출되었다. 염화수소와 브롬화수소는 각각 5개의 시료들에서 검출된 반면에 도료처리된 시료에서는 각각 1개만이 검출되었다. 그 외 일산화탄소와 이산화탄소 그리고 질소산화물은 모든 시료에서 공통적으로 검출되었다. 독성지수는 최소 3.5에서 최고 9.4의 값을 갖는 것으로 나타났다. 본 연구에서 수행한 NES 713 분석결과와 독성지수 산출 및 기존 국내 노출기준과의 비교를 수행해 본 결과는 다음과 같았다. 첫째, 현행 국내 기준 상 방염제품의 독성시험 등에 관한 기준이 없고, 둘째, 방염제품에 대한 연소가스 독성 등을 평가한 선행연구가 제한적이라는 점에서 의미가 있을 것으로 사료된다. 하지만 독성지수의 적용이 국내에서 이루어지고 있지 않은 현실에서 산출도나 독성지수의 위해정도를 평가하기 어렵고, 시료의 수량이 총 18개로서 많지 않았다는 점에서 전체 방염제품의 연소가스 독성의 잠재적인 위험성을 추정할 수는 있지만 대표성을 갖기에는 문제점이 있다는 한계성을 벗어날 수 없었다. 따라서 향후 후속 연구에서는 보다 많은 방염제품들을 대상으로 무작위 선정을 통한 연구 설계 및 실험 연구가 수행된다면 보다 객관적이고 대표성을 지닌 연구결과를 도출할 수 있을 것으로 기대한다.

  • PDF

Evaluation of the Measurement Uncertainty from the Standard Operating Procedures(SOP) of the National Environmental Specimen Bank (국가환경시료은행 생태계 대표시료의 채취 및 분석 표준운영절차에 대한 단계별 측정불확도 평가 연구)

  • Lee, Jongchun;Lee, Jangho;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Kim, Taekyu;Han, Areum;Kim, Myungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.6
    • /
    • pp.607-618
    • /
    • 2015
  • Five years have passed since the first set of environmental samples was taken in 2011 to represent various ecosystems which would help future generations lead back to the past environment. Those samples have been preserved cryogenically in the National Environmental Specimen Bank(NESB) at the National Institute of Environmental Research. Even though there is a strict regulation (SOP, standard operating procedure) that rules over the whole sampling procedure to ensure each sample to represent the sampling area, it has not been put to the test for the validation. The question needs to be answered to clear any doubts on the representativeness and the quality of the samples. In order to address the question and ensure the sampling practice set in the SOP, many steps to the measurement of the sample, that is, from sampling in the field and the chemical analysis in the lab are broken down to evaluate the uncertainty at each level. Of the 8 species currently taken for the cryogenic preservation in the NESB, pine tree samples from two different sites were selected for this study. Duplicate samples were taken from each site according to the sampling protocol followed by the duplicate analyses which were carried out for each discrete sample. The uncertainties were evaluated by Robust ANOVA; two levels of uncertainty, one is the uncertainty from the sampling practice, and the other from the analytical process, were then compiled to give the measurement uncertainty on a measured concentration of the measurand. As a result, it was confirmed that it is the sampling practice not the analytical process that accounts for the most of the measurement uncertainty. Based on the top-down approach for the measurement uncertainty, the efficient way to ensure the representativeness of the sample was to increase the quantity of each discrete sample for the making of a composite sample, than to increase the number of the discrete samples across the site. Furthermore, the cost-effective approach to enhance the confidence level on the measurement can be expected from the efforts to lower the sampling uncertainty, not the analytical uncertainty. To test the representativeness of a composite sample of a sampling area, the variance within the site should be less than the difference from duplicate sampling. For that, a criterion, ${i.e.s^2}_{geochem}$(across the site variance) <${s^2}_{samp}$(variance at the sampling location) was proposed. In light of the criterion, the two representative samples for the two study areas passed the requirement. In contrast, whenever the variance of among the sampling locations (i.e. across the site) is larger than the sampling variance, more sampling increments need to be added within the sampling area until the requirement for the representativeness is achieved.

Applicability test of broad leaf samples stored at the NESB for biomonitoring of airborne pollutants (국가환경시료은행 활엽 시료를 활용한 지역별 대기침적 오염물질 모니터링 활용성 검토)

  • Lee, Jongchun;Lee, Jangho;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Jang, Heeyon
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.6
    • /
    • pp.532-541
    • /
    • 2016
  • The National Environmental Specimen Bank (NESB) has been collecting broad leave samples to monitor environmental pollution from five different designated sampling areas. In order to ensure the reproducibility and comparability of the results, all the procedures from selecting trees and pooling leaves to make the representative sample are defined in the standard operation procedures(the SOP). The representative samples were subjected to the chemical analyses for some heavy minerals and Polycyclic Aromatic Hydrocarbons(PAHs). The uncertainty levels involved in each step of the SOP, that is, the sampling and the chemical analysis, were derived using the Robust ANOVA, which enables the relative comparison among the different levels of pollutants concentrations with confidence. Furthermore, the effect of the varying degrees of precipitation on the pollutants concentration of the leaves was also examined. Overall, the biological difference estimated from the duplicate samples was found to exceed the variation across the site, implying even aerial deposition over site. Samples from Gwanak Mt. showed highest heavy metal concentrations than the other sites. Washing off effect of the pollutants adhering in the form of particles on the leaf surface was found to be affected by the cumulative precipitation.

Validation of Suitable Zooplankton Enumeration Method for Species Diversity Study Using Rarefaction Curve and Extrapolation (종 다양성 평가를 위한 호소 생태계 동물플랑크톤 조사 방법 연구: 희박화 분석(rarefaction analysis)을 이용한 적정 시료 농축 정도 및 부차 시료 추출량의 검증)

  • Hye-Ji Oh;Yerim Choi;Hyunjoon Kim;Geun-Hyeok Hong;Young-Seuk Park;Yong-Jae Kim;Kwang-Hyeon Chang
    • Korean Journal of Ecology and Environment
    • /
    • v.55 no.4
    • /
    • pp.274-284
    • /
    • 2022
  • Through sample-size-based rarefaction analyses, we tried to suggest the appropriate degree of sample concentration and sub-sample extraction, as a way to estimate more accurate zooplankton species diversity when assessing biodiversity. When we collected zooplankton from three reservoirs with different environmental characteristics, the estimated species richness (S) and Shannon's H' values showed different changing patterns according to the amount of sub-sample extracted from the whole sample by reservoir. However, consequently, their zooplankton diversity indices were estimated the highest values when analyzed by extracting the largest amount of sub-sample. As a result of rarefaction analysis about sample coverage, in the case of deep eutrophic reservoir (Juam) with high zooplankton species and individual numbers, it was analyzed that 99.8% of the whole samples were represented by only 1 mL of sub-sample based on 100 mL of concentrated samples. On the other hand, in Soyang reservoir, which showed very small species and individual numbers, a relatively low representation at 97% when 10 mL of sub-sample was extracted from the same amount of concentrated sample. As such, the representation of sub-sample for the whole zooplankton sample varies depending on the individual density in the sample collected from the field. If the degree of concentration of samples and the amount of sub-sample extraction are adjusted according to the collected individual density, it is believed that errors that occur when comparing the number of species and diversity indices among different water bodies can be minimized.

Measurement Method of Final Residual Radioactivity of Radioactive Metallic Waste for Clearance (규제해제 대상 방사성 금속 폐기물 최종잔류방사능 측정법)

  • Seo, Bumkyoung;Ji, Youngyong;Hong, Sangbum;Lee, Keunwoo;Moon, Jeikwon
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.228-233
    • /
    • 2013
  • It has been continuously generated the requirement for the replacement of the main components such as a steam generator due to the deterioration of the nuclear power plant all around the world. Also, a large amount of radioactive metal was generated during the decommissioning in a short period. It is required to make an accurate measurement of the residual radioactivity for recycling the metal waste for releasing from regulatory control. In planning the measurement procedures, the influence of geometry, self-absorption, density and other relevant factors on the representativeness of the measurements should be considered for the decommissioning metal waste. In this study, the method for measurement procedures, the source term evaluation, the ways to secure representative samples, the measurement device for wide area and the self-absorption correction factors for different density were evaluated. The metal samples for measurement were prepared for securing the simple geometry and representative by melting process. The developed correction method for measuring the radioactivity a variety density of metal waste could improve the reliability of the evaluation results for clearance.

A Simplified Closed Static Chamber Method for Measuring Methane Flux in Paddy Soils (논토양(土壤)의 메탄 배출(排出) 측정(測定)을 위한 간역폐쇄정태(簡易閉鎖靜態) Chamber법(法))

  • Shin, Yong-Kwang;Lee, Yang-Soo;Yun, Seong-Ho;Park, Moo-Eon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • Various factors such as sampling height in the chamber, sampling interval, sampling time at daytime and the effects of pedoturbation on methane emission during chamber installation were evaluated using a simplified closed static chamber method to measure methane flux in paddy soils. Sampling height of the chamber for representative samples was 65cm. An additional DC fan was required to attain an even methane gradient in the chamber. Considering the change of methane concentration and air temperature in the chamber, sampling is recommended to finish within 30 minutes after starting sampling. The aim of setting DC fan in the chamber was to get the thermal equilibrium in the chamber as well as the representative samples. Suitable time to collect the gas samples representing the day's methane flux was 0900~1200 hours. Gas sampling was possible even after installation of small chambers if the elapsed time was more than 6 hours and supporting stand would be to be added to minimize pedoturbation.

  • PDF