• Title/Summary/Keyword: 시과

Search Result 42, Processing Time 0.022 seconds

Analysis of Elderly Driver's Visual Function (고령 운전자의 시각적 기능 분석에 관한 연구)

  • Kim, Jung Bok;Hwang, Jeong Hee;Chu, Byoung Sun
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.505-511
    • /
    • 2018
  • Purpose : This study investigated the visual functions of drivers aged over 65 year olds and drivers aged 50~65 year olds. In addition, difference of visual functions between professional drivers and normal drivers were investigated. Methods : Forty Driver aged over 65 year olds and 67 drivers aged less than 67 year olds were participated. All participants had more than 5 years of driving experiences and had no ocular pathology. Demographic data(gender, job, age, body condition) and visual functions such as contrast sensitivity(CS), stereopsis, glare recovery time and discomfort glare index were measured. Results : Constrast sensivity under photopic condition was higher with bus driver group. In addition, difference of CS at 12cpd and 18cpd were signifcantly different between normal drivers(1.57) and bus drivers(1.70) (p<0.05). There was no significant difference for glare recovery time, despite of trend of longer recovery time with age. Discomfort glare index was significantly different that normal drivers with more than 65 year olds had 3, taxi and truck driver presented almost 5 index score (p<0.05). Conclusion : Analysis of visual function of elderly drivers, it was confirmed that their visual functions decreased with age. Therefore, visual function tests such as CS, discomfort glare index and stereopsis in addition to current available test may need to be considered for drivers aged over 65.

Studies on the Seed Characteristics and Viabilities of Six Acer Species in Relation to Natural Regeneration in Korea (천연갱신과 관련된 한국산 단풍나무속 6종의 종자특성과 종자활력에 관한 연구)

  • Kim, Gab-Tae;Kim, Hoi-Jin
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.3
    • /
    • pp.358-364
    • /
    • 2011
  • To examine the possibility of natural regeneration of six Acer species in broadleaved mixed forest in Korean peninsula, samples of six Acer species' samaras were collected at several seed sources from September to October 2009 and 2010, and seed morphological characteristics and viability were studied using cutting method. Inflorescense type of Acer mandshuricum(AM), A. pseudosieboldianum(APS) and A. palmatum(AP) is corymb, that of A. pictum subsp. mono(APSM) and A. okamotoanum(AO) is flat-topped panicle, and that of A. ukurunduense(AU) is raceme. Number of seed-set per inflorescense proves the highest value 38.5 sets in AU and the lowest value 2.4 sets in APS. Diameter of the seeds proves highest value 13.5mm in AO, and the lowest value 4.7mm in APS. Angles between the wings proves the highest values $130.05^{\circ}$ in APS, and the lowest value $48.60^{\circ}$ in AU. Air dry weight of 20 seed-sets proves highest value 3,900mg, in AO, and the lowest value 404mg in AU. Viable seed ratio of AP proves 50%, and that of AU does 43.2%. Those of other four species ranges 8.6~22.2%. Considering postdispersal seed predators and disturbance of litter, viable seeds of APSM, AO, AM, and APS supplied in the natural forest in Korea might be insufficient for seedling establishment. This study showed that sound viable seed supply might be key factors of natural regeneration of major Acer species in Korea. The openings made by insect pests were observed on the seed-coat of APSM, AM, AU, and APS samara, and Bradybatus sharpi were observed in the samaras of APSM and AO. Further study on the seed insect fauna, pre- and post-dispersal seed viability, and annual variation on these factor should be needed.

Survey on a Disposal Method of Contact Lenses after Use (콘택트렌즈 사용 후 폐기처분에 대한 실태 조사)

  • Park, Il-nam;Kwon, Min-sun;Park, Ji-woong;Lee, Ki-Seok;Jung, Mi-A;Lee, Hae-Jung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.553-560
    • /
    • 2018
  • Purpose : To investigate a disposal method of disposing contact lenses and the recognition of environmental pollution by micro plastics which may be caused by the wrong disposal method of domestic contact lens wearers. Methods : Two hundred sixty one adults(124 males, 137 females, mean age $21.48{\pm}3.14years$) were participated in this study. They were given the questionnaire survey on contact lenses purchasing place, type of contact lenses, duration of wearing contact lenses, the disposal method of disposing contact lenses and the recognition of the occurrence of environmental pollution. Results : It appeared that eyeglass shop(50.0%) and contact lens shop(48.3%) were the main purchasing places, and the most common type of contact lenses were disposable lenses(38.5%) and daily wearing lenses(52.5%). On the duration of wearing contact lenses they answered more than 5 years(29.3%), less than 1 year (26.0%), less than 1 year to less than 3 years (26.0%), and on wearing a contact lens during a week they did 1-2 days (32.0%), 1 week (28.0%), 5-6 days (22.4%) and 3-4 days (17.6%). It was shown "no(78.3%)" and "yes(21.7%)" to the questionnaire of whether they received information or education about a disposal method at the place where the contact lens was purchased, and "no(87.5%)" and "yes(12.5%)" to the questionnaire of whether they received information or education from schools, public institutions or public media such as the internet. As for the disposal methods, landfill waste(45.6%), recycled garbage(29.6%), and drainage(16.8%) from the sink or toilet responded in order. Although men were more educated and informed about disposal than women (t=3.63189, p<0.00001), women were more aware of environmental pollution(t=2.44269, p=0.01605). Conclusion : In order to reduce the environmental pollution issue caused by the contact lens which does not decompose at the sewage treatment facility and become micro plastics, it is urgent to provide information about correct disposal methods after using contact lenses and to educate contact lens wearers.

Effects of Myopia Alleviation Lenses in accordance with Parents' Refractive Errors (부모의 굴절이상에 따른 근시완화렌즈 효과)

  • Cho, Yoon Chul;Kang, JoongGu;Leem, Hyun Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.569-577
    • /
    • 2018
  • Purpose : The study looked at how effective each group wearing MyoVison lens, MC lens, and Single Vision lensdepending on their parents' myopia condition. Methods : The study observed the changeof spherical equivalent among customers, who visited between January 2010 and December 2016,of an optical shop in Incheon Metropolitan City. And we observed MyoVision 152 eyes, MC Lens 86 eyes and Single Vision lens 270 eyes. This study was conducted using SPSS ver18, which analyzes the changes in average values of MyoVision, MC Lens, and Single Vision for a year.In each group, the differences in the group were compared using the Paired T-test and then one-way ANOVA (post-hoc; Bonferroni) Results : Group-to-group comparisons showed that MyoVision and MC Lens have a shorterinhibition than Single Vision. In particular, MyoVisionand MC Lens showed different relief effects depending on the degree of refraction of parents.When both parents had normal refractive, the change between MyoVision and Single Vision lens was $-0.35{\pm}0.05D$. When the father had a refraction MC lens were $-0.36{\pm}0.14D$ more effective than Single Vision. When only the mother had refraction, the mean value between MyoVision and Single Vision lens was $-0.37{\pm}0.06D$, and the mean between MC lens and Single Vision lens was $-0.38{\pm}0.08D$. And when both parents had refraction problems, the mean value change between MyoVision and Single Vision lens was $-0.28{\pm}0.07D$, and $-0.31{\pm}0.07D$, respectively. Conclusion : MyoVision and MC Lens appeared to have no effect on the functions of mitigating myopia in within group comparisons, but MyoVision and MC Lens showed reducing myopia than Single Vision in between group.

A Study on the Measurement of Dynamic Visual Acuity according to the Change of Accommodative Stimulus (조절자극 변화에 따른 동체시력(Dynamic visual acuity) 측정에 관한 연구)

  • Jin, Moon-Seog;Jeon, In-Chul
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the difference in the dynamic visual acuity between (DVA) the distance and near and the effect of change of accommodative stimulus on the dynamic visual acuity by the addition of the plus lens. Methods : The study involved 40 male and female adults ($22.84{\pm}2.43$ years old) with over 1.0 of visual acuity and without systemic disease or ocular disease. We compared the distance and near DVA and the change of DVA induced by the addition of the plus lens(+0.50D, +1.00D, +1.50D). Results : The distance DVA and near DVA are $78.86{\pm}19.46deg/sec$ and $76.90{\pm}18.05deg/sec$ respectively. The distance DVA was slightly higher(p=0.04). The higher the distance DVA, the higher the positive correlation with the near DVA and distance DVA, and distance DVA was higher in those who had higher the near DVA(r=0.95, p=0.00, Fig. 4). The near DVA according to the change of accommodative stimulus was $75.95{\pm}18.85deg/sec$ in full correction and the near DVA with +0.50D spherical power was $76.95{\pm}16.45$ but there was no statistically significant differences(p>0.05). However, the near DVA with +1.00D spherical power was $79.02{\pm}13.51deg/sec$ and it was slightly higher. Also, the near DVA with +1.50D spherical power was $84.28{\pm}18.96deg/sec$, there and it was statistically significant difference(p<0.05). Conclusion : There is no difference between distance and near DVA, but near DVA is also excellent if distance DVA is good. The DVA increases as added a plus lens for controlled accommodative stimulation changes.

Changes in Spherical Aberration and Coma Aberration after Wearing Aspheric Soft Contact Lens in Young Myopes (젊은 성인 근시안에서 비구면 소프트 콘택트렌즈 착용 후 구면수차와 코마수차의 변화)

  • Lim, Dong-Kyu;Kwon, Hyeok;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.469-482
    • /
    • 2018
  • Purpose : We investigated the change of spherical and comma aberrations after wearing aspheric soft contact lens (ASCL) in young myopes. Methods : Fifty young myopes ($23.15{\pm}1.70years$, spherical equivalent: $-2.90{\pm}1.75D$) were recruited and refractive errors were corrected using ASCL (Biotrue, Bausch+Lomb, USA). High order aberrations were measured in the 4 mm pupil size using the wavefront analyze and pupil sizes were measured with a pupillometer at the modes of scotopic condition (light off) at 3.5 m in the 100 lx illuminance condition. Results : Spherical aberrations and coma aberration of the 20s myopes were $0.026{\pm}0.031{\mu}m$ and $0.078{\pm}0.039{\mu}m$ respectively, and $0.019{\pm}0.026{\mu}m$ and $0.082{\pm}0.038{\mu}m$ after ASCL wear that spherical aberration was decreased and coma aberration was increased. However, spherical aberration was decreased in the 68% of the subject have positive spherical aberration, and increased in the 11% of the subject have negative spherical aberration. Coma aberration was increased in the 53% of the subject, did not change in the 19% of the subjects, and decreased in the 28% of the subject. Spherical aberration was not different with the refractive errors in low and moderate myopies, however, coma aberrations was higher in the higher myopes. Conclusion : In a scotopic condition without accommodation stimuli, spherical aberration is decreased after wearing ASCL, however in the subject have negative spherical aberration spherical aberration could be increased, and which is thought to be the influence of contact lens design and pupil size.

Thermographic Assessment on Temperature Change of Eye Surface in Cataract Surgery Observation (백내장수술 안에서 열화상카메라를 이용한 안구표면 온도의 변화)

  • Park, Chang Won;An, Young-Ju;Kim, Hyojin
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.497-504
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the temperature changes of the ocular surface before and after cataract surgery using thermography of a thermal imaging camera. Methods : The study included 75 patients (75 eyes) aged from 50 to 79 years who underwent cataract surgery. In the past, those who underwent corneal-related surgery, wearing contact lens, disorder of tear secretion and taking medication for systemic disease were excluded from this study. The temperature changes of the eyeball surface were measured using a thermal imager (Cox CX series, Answer, Korea) following Tear Break Up Time (TBUT) test, Mcmonnies questionnaire and Schirmer's Test in real time, Results : While the temperature of preoperative ocular surface was $35.20{\pm}0.54^{\circ}C$ and that of postoperative temperature was $35.30{\pm}0.53^{\circ}C$, the difference was not significant. The temperature changes in the ocular surface were statistically significant at $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) before the surgery and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) after the surgery. In comparison of the age groups, it was shown that the changes in the surface temperature before the surgery were from $-0.19{\pm}0.05{\Delta}$ ($^{\circ}C/sec$) to $-0.14{\pm}0.09{\Delta}$ ($^{\circ}C/sec$) in the 50s group, and from $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) to $-0.15{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) in 60s group, and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C$) to $-0.12{\pm}0.08{\Delta}/sec$) in the 70s group, showing significant changes in the ocular surface temperature at all ages. Conclusion : Following the cataract surgery, all the indicators of dry eye syndrome were decreased, and eye surface temperature changes were significant. The thermography technique of the ocular surface would be expected to be useful for the evaluation of various dry eye syndromes because it is easy to evaluate dry eye syndrome noninvasively and can be quantified.

Reliability of Autorefractometry after Corneal Refractive Surgery (레이저 굴절교정수술 후 자동굴절검사법의 신뢰성)

  • Lee, Ki-Seok
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.443-451
    • /
    • 2018
  • Purpose : To find out the reliability of autorefractometer after laser refractive surgery Methods : We measured and compared spherical and cylinder powers of those undergone LASEK surgery with 1.0 of naked vision after at least 3 months of the surgery with an autorefractometer(CANON Full Auto Ref-Keratometer RK-F1, Japan) and a retinoscope(Streak Retinoscope 18200, WelchAllyn, USA), and also applied spherical equivalent powers. The refractive status before surgery was divided into high, medium, and low myopia according to the results measured using an autorefractometer, and then analyzed again the reliability of the autorefractometer after surgery according to the preoperative refractive status. The agreement of two methods was identified using Bland-Altman(Bland-Altman limits of agreement(LoA)). Results : After the surgery, when comparing spherical, cylinder and equivalent powers in the whole data measured by autorefractometry and retinoscopy significant differences were found(p<0.01). According to the degree of refractive errors, all sort of refractive errors was shown significantly different(p<0.01) except for cylinder power of the medium myopia. In general, the refractive errors especially spherical and spherical equivalent powers by autorefractometry were shown a myopic trend from -0.38 D to -0.53 D. On the other hand, it was shown a hyperopic trend of approximately +0.30 D using retinoscopy. In comparison of two objective refractions, it was shown a myopic trend as $-0.51{\pm}0.45D$(LoA +0.36 D ~ -1.39 D) and compatible. Conclusion : Even though it would be positive in terms of compatibility of the methods, it is necessary that the glasses should be prescribed by subjective refraction since autorefractometry is shown myopic in those undergone the surgery and suffering from myopic regression.

Correlation between Corneal Ablation Amount and Intraocular Pressure after Corneal Refractive Surgery (각막굴절교정수술 후 각막절삭량과 안압변화의 상관관계)

  • Jung, Mi-A;Lee, Eun-Hee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.543-551
    • /
    • 2018
  • Purpose : The purposes of this study were to evaluate the changes of intraocular pressure according to corneal ablation amount after corneal refractive surgery and the changes of intraocular pressure according to refractive errors before corneal refractive surgery. Methods : The mean age of adults who underwent LASIK corneal refractive surgery were $37.34{\pm}7.42years$, and 108 adults(48 males, 60 females) were participated in this study. Refractive errors, intraocular pressure, and corneal ablation amount were measured using an autorefractor, a noncontact tonometer, and an excimer laser. All test values were considered statistically significant when p<0.05. Results : The mean intraocular pressure before corneal refractive surgery was $15.08{\pm}2.60mmHg$ in males and $14.16{\pm}2.67mmHg$ in females. The decrease of intraocular pressure after corneal refractive surgery were 4.22mmHg in males and 3.61mmHg in females. Spherical equivalent power were $-3.89{\pm}2.17D$ in males and $-4.45{\pm}2.92D$ in females before corneal refractive surgery, and $-0.10{\pm}0.46D$ in males and $-0.04{\pm}0.46D$ in females after corneal refractive surgery. The corneal ablation amount after corneal refractive surgery were statistically significant, with $53.95{\mu}m$ in males and $61.26{\mu}m$ in females. There was significant correlation between corneal ablation amount and decrease of intaocluar pressure(r=0.2299, p<0.001). As the growth of corneal ablation amount in males, the decrease of intraocular pressure was significantly increased. As the growth of refractive error, the amount of decrease in intraocular pressure was also significant. The decrease of intraocualr pressure were $3.04{\pm}2.18mmHg$ in low refractive error, $4.10{\pm}2.16mmHg$ in middle refractive error, and $4.65{\pm}3.29mmHg$ in high refractive error. Conclusion : We found that intraocular pressure decreased after corneal refractive surgery by noncontact tonometer and the change of intraocular pressure which is an important index for glaucoma diagnosis, may affect the judgment of eye disease. We think that a preliminary questionnaire whether corneal refractive surgery is necessary for the measurement of intraocular pressure.

Analysis of Light Transmittance according to the Array Structure of Collagen Fibers Constituting the Corneal Stroma (각막실질 콜라겐섬유의 배열구조에 따른 광투과율 분석)

  • Lee, Myoung-Hee;Kim, Young-Chul
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.561-568
    • /
    • 2018
  • Purpose : The size and regular array of the collagen fibers in the corneal stroma have very close correlation with transparency. Simulation was carried out to investigate the change of light transmittance according to the array structure and collagen fiber layer thickness. Methods : The collagen fibers in corneal stroma were arranged in regular hexagonal, hexagonal, square and random shapes with OptiFDTD simulation software, and the light transmittance was analyzed. In square array, the light transmittance according to the density change was confirmed by when the number of collagen fibers in the simulation space was the same and the light transmittance was examined when the number and density of collagen fibers were changed. Results : When the number of collagen fibers is the same, the density becomes smaller and the thickness of the fibrous layer becomes thicker in order of arrangement of square, regular hexagonal, random and hexagonal. As a result of measuring the light transmittance by changing the array structure, the light transmittance measured at the detector at the same position was almost similar regardless of the array structure. In the detectors D0, D1, D2 and D3, the maximum transmittance is shown in square, hexagonal and square, regular hexagonal and regular hexagonal array structure, and the minimum transmittance is hexagonal, random, hexagonal and square, and square array structure. However, the difference between the maximum transmittance and the minimum transmittance was almost the same within 1%. When the number of collagen fibers was the same, the light transmittance of the rectangular array structure decreased with increasing fiber layer thickness. And as the thickness increased, the light transmittance decreased more when the number of collagen fibers decreased. Conclusion : Even though the collagen array structure changed, the light transmittance is almost similar regardless of the arrangement structure. However, as the array structure was changed, the thickness of the collagen fiber layer changed, and as the thickness increased, the light transmittance decreased. In other words, the transparency of the corneal stroma is more closely related to the thickness of the fibrous layer than the array of collagen fibers.