• Title/Summary/Keyword: 시간장치

Search Result 4,177, Processing Time 0.038 seconds

Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident (방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구)

  • Park, Byeong Ryong;Ha, Wi-Ho;Park, Sunhoo;Lee, Jin Kyeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.194-201
    • /
    • 2015
  • We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by $^{137}Cs$ gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity ($R^2$ > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

The Differences of Anthropometric and Polysomnographic Characteristics Between the Positional and Non-positional Obstructive Sleep Apnea Syndrome (체위 의존성 및 체위 비의존성 폐쇄성 수면 무호흡증후군의 신체계측인자 및 수면구조의 차이)

  • Park, Hye-Jung;Shin, Kyeong-Cheol;Lee, Choong-Kee;Chung, Jin-Hong;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.956-963
    • /
    • 2000
  • Backgrounds : Obstructive sleep apnea syndrome(OSA) can divided into two groups, positional(PP) and non-positional(NPP) obstructive sleep apnea syndrome, according to the body position while sleeping. In this study, we evaluated the differences of anthropometric data and polysomnographic recordings between the two types of sleep apnea syndrome. Materials : Fifty patients with OSA were divided two groups by Cartwright's criteria. The supine respiratory disturbance index (RDI) was at least two times higher than the lateral RDI in the PP group, and the supine RDI was less than twice the lateral RDI in the NPP group. This patients underwent standardized polysomnographic recordings. The anthropometric data and polysomnographic data were analyzed, statistically. Results : Of all 50 patients, 30% were found to be positional OSA. BMI was significantly higher in the PP group(p<0.05). Total sleep time was significantly longer in the PP group (350.6$\pm$28.2min, 333.3$\pm$46.0min, (p<0.05). Sleep efficiency was high in the PP group(89.6$\pm$6.4%, 85.6$\pm$9.9%, p<0.05). Deep sleep was significantly higher and light sleep was lower in the PP group than in the NPP group but no difference was observed in REM sleep between the two groups. Apnea index(AI) and RDI were significantly lower( 17.0$\pm$10.6, 28.5$\pm$13.3, p<0.05) and mean arterial oxygen saturation was higher in the PP group(92.7$\pm$1.8%. p<0.05) than in the NPP group. Conclusion : Body position during sleep has a profound effect on the frequency and severity of breathing abnormalities in OSA patients. A polysomnographic evaluation for suspected OSA patients must include monitoring of the body position. Breathing function in OSA patients can be improved by controlling their obesity and through postural therapy.

  • PDF

Effect of Cognitive Affordance of Interactive Media Art Content on the Interaction and Interest of Audience (인터랙티브 미디어아트 콘텐츠의 인지적 어포던스가 관람자의 인터랙션과 흥미에 미치는 영향)

  • Lee, Gangso;Choi, Yoo-Joo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.9
    • /
    • pp.441-450
    • /
    • 2016
  • In this study, we investigate the effect of the level of cognitive affordance which explains an explicit interaction method on the interest of viewers. Viewer's recognition of the interaction method is associated with cognitive affordance as a matter of visual-perceptual exposure of the input device and viewer's cognition of it. The final goal of the research on affordance is to enhance the audience participation rather than the smooth interation. Many interactive media artworks have been designed with hiding the explicit explanation to the artwork due to worry that the explicit explanation may also hinder the induction of impressions leading the viewer to an aesthetic experience and the retainment of interest. In this context, we set up two hypotheses for study on cognitive affordance. First, the more explicit the explanation of interaction method is, the higher the viewer' understanding of interaction method is. Second, the more explicit the explanation of interaction method is, the lower the interest of the viewer is. An interactive media art work was manufactured with three versions which vary in the degree of visual-perceptual information suggestion and we analyzed the participation and interest level of audience in each version. As a result of the experiments, the version with high explicitness of interaction was found to have long time spent on watching and high participation and interest of viewers. On the contrary, the version with an unexplicit interaction method was found to have low interest and satisfaction of viewers. Therefore, regarding usability, the hypothesis that a more explicit explanation of interaction would lower the curiosity and interest in exploration of the viewer was dismissed. It was confirmed that improvement of cognitive affordance raised the interaction of the work of art and interest of the viewer in the proposed interactive content. This study implies that interactive media art work should be designed in view of that the interaction and interest of audience can be lowered when cognitive affordance is low.

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Effects of Glue Sniffing on Weight Increase or Central Nervous System of Young Rat (반복된 본드 흡입이 백서의 정상발육에 의한 체중증가와 중추신경계에 미치는 영향)

  • Kim, Heon;Kim, Sun-Min;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.222-230
    • /
    • 1993
  • Industrial glues, known as 'Bonds' in Korea, contain many kinds of organic solvents, and glue sniffing of youths became one of the social problems in Korea. Mixed exposures to solvents by glue sniffing may induce chronic toxicities different from those by exposures to solvents of single component. To test effects of the glue sniffing on weight gain or central nervous system, two groups of 20 male Sprague-Dawley rats were exposed to air(control group) or vapors of the glues to narcotic status(exposed group), and weight check, tail flick test, hot plate test, rotarod treadmill test were done on the 14th,24th, 36th, 45th, 53rd, 86th, 102nd, 117th, 134th and 151st days after the first exposure. On the 188th day, their brains were excised and examined by a pathologist. Weight gain, controlled against time change, showed significant difference between the groups, but response times in tail flick test, hot plate tests, and rotarod treadmill test didn't. In pathological examination with blind method, no macroscopic or microscopic differences were found between the two groups. These results suggests that organic lesion in central nervous system may not ensue glue sniffing, but, before firm conclusion, more studies in various exposure conditions should be followed.

  • PDF

Current Trend of European Competition Damage Actions (유럽 경쟁법상 손해배상 청구제도의 개편 동향과 그 시사점)

  • Lee, Se-In
    • Journal of Legislation Research
    • /
    • no.53
    • /
    • pp.525-551
    • /
    • 2017
  • This Article discusses the current trend of European competition damage actions focused on the recent Damage Directive and its transposition by the United Kingdom and Germany. The relevant Directive was signed into law in November 2014, and it requires the EU Member States to adopt certain measures to support competition damage actions. The required measures and principles by the Directive include right to full compensation, rebuttable presumption of harm, extensive disclosure of evidence, use of pass-on for defense and indirect purchaser suits. Although many Member States did not meet the deadline to transpose the Directive, the end of 2016, it is reported that 23 Member States have now, as of September 2017, made enactments according to the Directive. When we look at the transposition done by the United Kingdom and Germany, the revisions on their competition laws closely follow the contents of the Directive. However, it will take quite a long time before the amended provisions apply to actual cases since most of the new provisions apply to the infringement that take place after the date of the amendment. A similar situation regarding application time may happen in some other Member States. Furthermore, even if the terms of the competition laws of the Member States become similar following the Directive, the interpretations of the laws may differ by the courts of different countries. EU also does not have a tool to coordinate the litigations that are brought in different Member States under the same facts. It is true that the EU made a big step to enhance competition damage actions by enacting Damage Directive. However, it needs to take more time and resources to have settled system of competition private litigation throughout the Member States. Korea has also experienced increase in competition damage actions during the last fifteen years, and there have been some revisions of the relevant fair trade law as well as development of relevant legal principles by court decisions. Although there are some suggestions that Korea should have more enactments similar to the EU Directive, its seems wiser for Korea to take time to observe how EU countries actually operate competition damage actions after they transposed the Directive. Then, it will be able to gain some wisdom to adopt competition action measures that are suitable for Korean legal system and culture.

Multi-purpose Geophysical Measurements System Using PXI (PXI를 이용한 다목적 물리탐사 측정 시스템)

  • Choi Seong-Jun;Kim Jung-Ho;Sung Nak-Hun;Jeong Ji-Min
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.3
    • /
    • pp.224-231
    • /
    • 2005
  • In geophysical field surveys, commercial equipments often fail to resolve the subsurface target or even sometimes fail to be applied because they do not fit to the various field situations or the physical properties of the medium or target. We developed a geophysical measurement system, which can be easily adapted for the various field situations and targets. The system based on PXI with A/D converter and some stand alone equipment such as Network Analyzer was applied to borehole radar survey, borehole sonic measurement and electromagnetic noise measurement. The system for borehole radar survey consists of PXI, Network Analyzer, dipole antennas, GPIB interface is used for PXI to control Network Analyzer. The system for borehole sonic measurement consists of PXI, 24 Bit A/D converter, high voltage pulse generator, transmitting and receiving piezoelectric sensors. The electromagnetic noise measurement system consists of PXI, 24 Bit A/D converter, 2 horizontal component electric field sensors and 2 horizontal and 1 vertical component magnetic filed sensors. The borehole radar system has been successfully applied to detect the width of the artificial tunnel through which the borehole pass and to image buried steel pipe, while the commercial borehole radar equipment failed. The borehole sonic system was tested to detect the width of artificial tunnel and showed a reasonable result. The characteristic of electromagnetic noise was grasped at an urban area with the data from the electromagnetic noise measurement system. The system is also applied to characterize the signal distortion by induction between the electric cables in resistivity survey. The system can be applied various geophysical problems with a simple modification of the system and sensors.

Effect of Physical Control Technology on Aspergillus ochraceus Reduction (물리적 제어기술이 Aspergillus ochraceus 저감화에 미치는 영향)

  • Lee, Eun-Seon;Kim, Jong-Hui;Kim, Bu-Min;Oh, Mi-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.5
    • /
    • pp.447-453
    • /
    • 2021
  • In this study, the effectiveness of physical control technology, a combined light sterilization (LED, UV) and hot water treatment in reducing Aspergillus ochraceus for food production environment was investigated. In brief, 1 mL aliquot of A. ochraceus spore suspension (107-8 spore/mL) was inoculated onto stainless steel chips, which was then dried at 37℃, and each was subjected to different physical treatment. Treatments were performed for 0.5, 1, 2, 5, 8, and 11 hours to reduce the strains using a light-emitting diode, but no significant difference was confirmed among the treatments. However, a significant reduction was observed on the chips treated with UV-C exposure and hot water immersion. After being treated solely with 360 kJ/m2 of UV-C on stainless steel chip, the fungi were significantly reduced to 1.27 log CFU/cm2. Concerning the hot water treatment, the initial inoculum amount of 6.49 log CFU/cm2 was entirely killed by immersion in 83℃ water for 5 minutes. Maintaining a high temperature for 5 minutes at the site is difficult. Thus, considering economic feasibility and usability, we attempted to confirm the appropriate A. ochraceus reduction conditions by combining a relatively low temperature of 60℃ and UV rays. With the combined treatments, even in lukewarm water, A. ochraceus decreased significantly through the increases in the immersion time and the amount of UV-C irradiation, and the yield was below the detection limit. Based on these results, if work tools are immersed in 60℃ lukewarm water for 3 minutes and then placed in a UV sterilization device for more than 10 minutes, the possibility of A. ochraceus cross-contamination during work is expected to be reduced.

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.