• Title/Summary/Keyword: 승강장 사고

Search Result 23, Processing Time 0.022 seconds

A Study on the Reliability Analysis of Platform Safety Step System in Urban Railway (도시철도 승강장 안전발판 시스템 신뢰도 분석에 관한 연구)

  • Park, Min-Heung;Lee, Jeong-Hun;Kwak, Hee-Man;Kim, Min-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3685-3691
    • /
    • 2015
  • We developed the platform safety step system for the passenger to avoid misstep accident and secure the pedestrian safety. In this study, we classify platform safety step system into hierarchy system and predict the failure rate of each part and calculate the failure rate & MTBF(Mean Time Between Failure) of each module(sub-system) by means of RBD(Reliability Block Diagram) & FTA(Fault Tree Analysis). Finally, we will propose the reliability analysis results for RAMS analysis of platform safety step system.

Analysis of Passenger Refuge Model Using EXODUS Refuge Simulator: Case of the Daegu Underground Station Fire (EXODUS 피난시물레이터를 이용한 대구지하역사화재 승객피난모델분석)

  • Lee, Chang-Hyun;Jang, Yong-Jun;Park, Won-Hee;Kim, Dong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1807-1813
    • /
    • 2007
  • The study aims at analyzing an underground station refuge model using EXODUS, one of the refuge simulation programs. The model for simulation is the Daegu Subway (Joongang-ro station). The details of the accident are referred to as the simulation condition the refuge time of traveling from the $3^{rd}$ basement platform to the $1^{st}$ basement is mainly calculated, with passengers numbering 1,000 including 329 at car 1079, 320 at car 1080, and 360 who are not on board. Reference data is used to set up the position of passengers. CFAST fire simulator is also used, and a fast curve among the $t^2$ growth curves, selected as fire growth scenario. The zone is divided into a total of 24 including 18 at the $3^{rd}$ basement platform and 6 at the $2^{nd}$ basement the $1^{st}$ basement is excluded in the fire simulation, however.

  • PDF

Evacuation safety analysis depending on the type of subway platform and ticket barrier (지하철 승강장과 개찰구 유형별 대피안전성 분석)

  • Park, Byoung-Jik;Park, Il-Gyu;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.237-242
    • /
    • 2015
  • With the rapid development of modern society, subway has become one of the most typical urban transport systems. Since fire accident occurred at Daegu subway in 2003, importance of life safety and disaster prevention have been widely recognized and many studies have been carried out. As a result of these studies, fire-retardant and non-combustible interior material and platform screen door with passenger guide indication device have been developed, but studies on a subway evacuation criteria have been in a stalemate. Therefore, this study is intended to improve the subway evacuation standard. It is very difficult to take into account whole subway system, so a typological approach to a ticket was carried out referring to previous studies focused on a subway platform. this paper selected the most common subway platforms and estimated evacuation time among 10 platforms from previous studies and 8 from this study. As a result, evacuation time exceeded 6 minutes which is the guideline of existing standard. Therefore, it is necessary to update the standard for evacuation time and add supplementary conditions which can help establishing the measures for safety facilities and prevention measures.

Unsteady Wind Pressure Analysis on PSD Considering Subway Station Configurations (지하철 역사 형상을 고려한 PSD 비정상 풍압해석)

  • Kim, Yu-Sung;Kim, Yo-Han;Shin, Kwang-Bok;Lee, Eun-Kyu;Kim, Dong-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • In this study, unsteady wind pressure analyses on platform screen door (PSD) have been conducted considering the flow intereference effects between the moving train and the configuration of subway station. The major role of PSD prevents passenger accidents, wind pressure, polluted dust and noise when the train is entering the station platform. Computational fluid dynamic method with moving gird algorithm has been adopted to accurately predict unsteady pressure levels exerted on the PSD. Closed and open type station configuration are considered. Also, wind pressure levels for passing and stopping drive motion of the entering train are presented and practically compared each other.

A Study on Slow Driving of Metropolitan Train for Disorder Condition of Platform Safety Gate using LTE-R and Beacon (LTE-R과 비콘을 활용한 승강장안전문 장애발생 시 열차 서행운전에 관한 연구)

  • Joh, Eungyoung;Noh, Jowon;Kim, Jin-Tea;Lee, Sunghwa
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.31-36
    • /
    • 2020
  • The LTE-R system is a system consisting of a packet network that provides all IP-based services. Continuous failures related to the platform safety gate and subsequent safety accidents related to passengers and safety gate workers continue. The secondary damage caused by the failure of the platform safety door and the related human life damage have emerged as a major social issue.. By linking the beacon system to the Long Term Evoluton-Railway (LTE-R) network, an LTE-based railway wireless network currently in operation or being installed, it precisely locates trains and provides standardized fault alerts to train crews. When entering into the station, ultimately we will decelerate the train and reduce the accidents of metropolitabn railroad traffic by securing safe driving.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

The Comparative Analysis of Fire-Driven Flow Simulation for Dae-gu Subway Station Using FDS and Fluent. (FDS 및 FLUENT를 이용한 대구지하역사 화재유동 해석비교)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Kim, Hag-Beom;Kim, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.50-55
    • /
    • 2008
  • The comparative analysis of fire-driven flow simulation for Dae-Gu subway station was performed using FDS and Fluent. The boundary condition was obtained from analyzed data for Dae-Gu subway fire accident which had been outbreaked in 2003 year. The smoke flow in the second and third basement has been analyzed. The CO and temperature distribution in the train units and station platform have been obtained with FDS and FLUENT and compared with each other. Total simulation time is 600s and the results are compared of each 10sec The analyzed data will be applied to the passenger evacuation simulation for Dae-Gu subway station and used to optimal design method.

  • PDF

The Passenger Evacuation Simulation Using Fluent and EXODUS (Fluent 와 EXODUS를 이용한 승객피난 시뮬레이션)

  • Jang, Yong-Jun;Park, Won-Hee;Lee, Chang-Hyun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1346-1353
    • /
    • 2007
  • The simulation analysis of fire-driven flow and passenger evacuation in Daegu subway station, Chung-Ang, have been performed. The first location of outbreak of fire is inside passenger car in the third basement in Chung-Ang station. The smoke flow in the second and third basement has been analyzed using FLUENT 6.2. The CO(carbon monoxide) and temperature distribution in the train units and station platform have been obtained and transferred to input data for evacuation simulation. The highest temperature in the train units was 1500K. For the simulation of passenger evacuation, EXODUS has been used for whole basements (level 1${\sim}$ level 3) in the station. Total number of people was assumed to be one thousand and 640 were placed inside train and 360 were placed outside train. In evacuation simulation, an average of 135 passengers were killed and an average time to evacuate takes 10min 19sec. The main evacuation routes used by passengers were investigated and the cause of death was identified by evacuation simulation.

  • PDF

Comparison of detection rates Area sensors and 3D spatial division multiple sensors for detecting obstacles in the screen door (스크린도어의 장애물 검지를 위한 Area센서와 다중공간분할 3D센서의 검지율 비교 분석)

  • Yoo, Bong-Seok;Lee, Hyun-Su;Jin, Ju-Hyun;Kim, Jong-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.561-566
    • /
    • 2016
  • A subway platform is equipped with screen doors in oder to avoid accidents of passengers, where Area sensors are installed for detecting obstacles in the screen doors. However, there exist frequent operating errors in screen doors due to dusts, sunlight, snow, and bugs. It is required to develope a detection device which reduces errors and elaborates detection function. In this paper, we compared the detection rates of the Area sensor the 3D sensor using CCTV-based image data with installing sensors at the screen door in Munyang station Daegu, where 3D sensor is applied with the space division multiple detection algorithms. It is measured that the detection rate of 3D sensor and Area sensor is approximately 89.61% and 78.88%, respectively. The results confirmed that 3D senor has higher detection rate compared with Area sensor with the rate of 6.87~9.79%, and 3D sensor has benefit in the aspect of installation fee.

Cause Analysis and Measure for Accident of Door Detachment in Elevator Platform (승강장 도어이탈 안전사고에 대한 원인분석 및 대책)

  • Kim, Eui-Soo;Kim, Sang-Hyeon;Kim, Dong-Hwan;Park, Nam-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2007
  • A Recently elevator accidents were occurred and increased due to carelessness of user and violent behavior. The accident of door detachment in elevator platform by electronic motor scooter show a example of safety concerns and insensibility for safety awareness. In this report, we review the cause of accident of door detachment in elevator platform by electronic motor scooter, and show some suggestions of preventing from the safety concerns about this case.