• Title/Summary/Keyword: 습표면

Search Result 238, Processing Time 0.024 seconds

Case Study on the Mixed Layer Development using the UHF Radio Sounding (고도별 UHF 원격 관측을 이용한 혼합층 발달 사례 분석)

  • Kim, Sang-Jin;Kwon, Byung Hyuk;Kim, Kwang-Ho;Kim, Park Sa;Kim, Min-Seong;Jo, Won Gi;Yoon, Hong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.253-264
    • /
    • 2018
  • The GPS radiosonde is designed to conduct a full synoptic sounding to balloon burst using data generated from precision meteorological sensors and the GPS satellite network. The GPS radiosonde include proven, accurate temperature, humidity and capacitance aneroid pressure sensors. The atmospheric boundary layer was intensively observed in three islands of the west sea from 18 LST on March 9, 2016 to 06 LST on March 12, 2016. We investigated the restriction of nocturnal stable layer and rather the development of the mixed layer at night. On March 9, nocturnal mixed layer was developed by buoyancy heat flux. On the other hand, on March 10, the shear production was higher especially at 21 LST when the mixed layer height was the highest during the intensive observation period. The wind shear and the surface heat flux which produce the turbulent kinetic energy played an important role to grow the mixed layer even at night.

Production of spherical granule type yogurt with improving convenience and preservation (편리성 및 저장성이 증진된 구형과립 요구르트 제조)

  • Shin, Myung-Gon
    • Food Science and Preservation
    • /
    • v.24 no.5
    • /
    • pp.559-564
    • /
    • 2017
  • Yogurt contains many microorganisms that are beneficial to human health, and is a probiotic that supplies many nutrients such as calcium and protein. It is difficult to safety preserve for a long time because it possesses a high content of water. To address this problem, powdered "instant" yogurt has been developed, but it has flaws low flowability and solubility. Therefore, yogurt was granulated using a fluidized bed granulator to increase flowability and solubility. The fluidized bed granulator was designed by using response surface methodology (RSM), whose variables were feeding rate (FR), atomization air pressure (AP) and product temperature (PT). After being granulated, the yogurt was analyzed for yield and lactic acid bacteria count. The maximum yield of yogurt granules was 79.42%, at FR of 0.54 mL/min, AP of 2.64 kPa, and PT of $58.18^{\circ}C$, and the colony count for lactic acid bacteria was more than $6log^{10}\;CFU/g$. Therefore, spherical granulation of yogurt using a fluidized bed granulator could be used for making convenient probiotic products with improved flowability and solubility.

Heat Transfer in the Passive Containment Cooling System (수동형 격납용기 냉각계통에서의 열전달)

  • Cha, Jong-Hee;Jun, Hyung-Gil;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.281-291
    • /
    • 1995
  • The objective of this work is to obtain the experimental data for the heat transfer processes occurring both on the inside and outside surfaces of containment steel wall with dry and wet outer surface conditions in the passive containment cooling system. The test model represented a 60$^{\circ}$ section of a containment vessel based on the AP 600 geometry. Major linear dimensions of the test model ore reduced tv a factor of ten. To simulate the decay heat a steam generator heated by electricity was placed in the test model. The maximum heat flux was 8.91 kW/$m^2$. Two types of tests were performed. The one was the tort on the natural convection of air without water film flow. The other was the evaporative heat transfer test with the falling water film flow and natural air draft. no test result shooed that the heat transfer capability by the natural convection from the containment to the air without oater film flow was limited at about 1.48 kW/$m^2$ heat flux. It was found that the heat removal capability was remarkably enhanced in the tests with the waster film flow and air draft. The obtained heat transfer data ore compared with the existing correlations.

  • PDF

Characteristics of Poly(arylene ether sulfone) Membrane for Proton Exchange Membrane Fuel Cells (고분자전해질 연료전지용 Poly(arylene ether sulfone) 막의 특성)

  • Jeong, Jae-Jin;Shin, Yong-Cheol;Lee, Moo-Seok;Lee, Dong-Hoon;Na, Il-Chai;Lee, Ho;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.556-560
    • /
    • 2013
  • Recently, there are many efforts focused on development of more economical non-fluorinated membranes for use in PEMFCs (Proton Exchange Membrane Fuel Cells). In this study, characteristics of poly(arylene ether sulfone)(PAES) were compared with fluorinated membrane at PEMFC operation condition. I-V polarization curve, hydrogen crossover, electrochemical surface area, membrane resistance and charge transfer resistance were measured. PAES membrane showed similar performance compared with fluorinated membrane at 100% relative humidity, but the performance of PAES membrane decreased largely due to low ionic conductivity at low relative humidity.

Characteristics of Proton Exchange Membrane Fuel Cells(PEMFC) Membrane and Electrode Assembly(MEA) Using Sulfonated Poly(ether ether ketone) Membrane (sPEEK 막으로 제조한 고분자전해질 연료전지(PEMFC) 막전극합체(MEA)의 특성)

  • Lee, Hye-Ri;Lee, Se-Hoon;Hwang, Byung-Chan;Na, Il-Chai;Lee, Jung-Hun;Oh, Sung-June;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.181-186
    • /
    • 2016
  • Recently, there are many efforts focused on development of more economical non-fluorinated membranes for use in PEMFCs (Proton Exchange Membrane Fuel Cells). In this study, characteristics of sulfonated Poly(ether ether ketone) (sPEEK) were compared according to degrees of sulfonation (DS), relative humidity, cell temperatures at PEMFC operation condition. I-V polarization curve, hydrogen crossover, electrochemical surface area, membrane resistance and charge transfer resistance were measured. sPEEK membrane showed high performance at high DS, high temperature and high relative humidity, in particular, performance of sPEEK membrane decreased largely due to low ionic conductivity at low DS and low relative humidity.

Interfacial Adhesion between Screen-Printed Ag and Epoxy Resin-Coated Polyimide (에폭시수지가 도포된 폴리이미드와 스크린 프린팅 Ag 사이의 계면접착력 평가)

  • Park, Sung-Cheol;Kim, Jae-Won;Kim, Ki-Hyun;Park, Se-Ho;Lee, Young-Min;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The interfacial adhesion strengths between screen-printed Ag film and epoxy resin-coated polyimide were evaluated by $180^{\circ}$ peel test method. Measured peel strength value was initially around $164.0{\pm}24.4J/m^2$, while the heat treatment during 24h at $120^{\circ}C$ increase peel strength up to $220.8{\pm}19.2J/m^2$. $85^{\circ}C/85%$ RH temperature/humidity treatment decrease peel strength to $84.1{\pm}50.8J/m^2$, which seems to be attributed to hydrolysis bonding reaction mechanism between metal and adhesive epoxy resin coating layer.

Effect of Nylon/Aramid Filaments Characteristics on the Physical Property of Air Textured Yarns for Protective Garment (Nylon/아라미드 원사특성이 방호의류용 에어텍스쳐사의 물성에 미치는 영향)

  • Kim, Hyun-Ah
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.75-82
    • /
    • 2014
  • This study investigated the physical properties of aramid/nylon ATY and aramid ATY for protective garments according to the aramid and nylon characteristics fed on the core and effect components of air jet texturing equipment. Tenacity decrease of aramid ATY was much more higher than that of nylon ATY because of slick of aramid filament surface. Tenacity of aramid/nylon ATY was most affected by the tenacity of nylon on the effect component of ATY. Breaking strain of nylon ATY was two times higher than that of nylon before air jet texturing, then, in case of aramid ATY and aramid/nylon ATY, were 5.9-6.7 times higher than those before air jet texturing. Initial modulus decrease of aramid ATY showed 86.5% of initial modulus of aramid before air jet texturing, then aramid/nylon hibrid ATY showed arithmetic average value of initial modulus of aramid and nylon ATY. Wet and dry thermal shrinkages of aramid/nylon hybrid ATY were dominated by those of nylon filament on the effect component of ATY.

Irreversible Charge Trapping at the Semiconductor/Polymer Interface of Organic Field-Effect Transistors (유기전계효과 트랜지스터의 반도체/고분자절연체 계면에 발생하는 비가역적 전하트래핑에 관한 연구)

  • Im, Jaemin;Choi, Hyun Ho
    • Journal of Adhesion and Interface
    • /
    • v.21 no.4
    • /
    • pp.129-134
    • /
    • 2020
  • Understanding charge trapping at the interface between conjugated semiconductor and polymer dielectric basically gives insight into the development of long-term stable organic field-effect transistors (OFET). Here, the charge transport properties of OFETs using polymer dielectric with various molecular weights (MWs) have been investigated. The conjugated semiconductor, pentacene exhibited morphology and crystallinity, insensitive to MWs of polymethyl methacrylate (PMMA) dielectric. Consequently, transfer curves and field-effect mobilities of as-prepared devices are independent of MWs. Under bias stress in humid environment, however, the drain current decay as well as transfer curve shift are found to increase as the MW of PMMA decreases (MW effect). The charge trapping induced by MW effect is irreversible, that is, the localized charges are difficult to be delocalized. The MW effect is caused by the variation in the density of polymer chain ends in the PMMA: the free volumes at the PMMA chain ends act as charge trap sites, corresponding to drain current decay depending on MWs of PMMA.

A Review of Footpad Dermatitis Characteristics, Causes, and Scoring System for Broiler Chickens (육계 발바닥 피부염의 발생원인, 점수 시스템 및 관련 연구 동향에 대한 총설)

  • Jeon, Jin-Joo;Hong, Eui-Chul;Kang, Hwan-Ku;Kim, Hyun-Soo;Son, Jiseon;You, Are-Sun;Kim, Hee-Jin;Kang, Bo-Seok
    • Korean Journal of Poultry Science
    • /
    • v.47 no.4
    • /
    • pp.199-210
    • /
    • 2020
  • Footpad dermatitis (plantar surface footpad lesions) is an increasing problem in the global poultry industry, affecting foot quality, overall welfare, and production performance. The growing consumer demand for chicken feet in Asian markets has given poultry companies interest in reducing footpad dermatitis. The lesions are multiply associated with various factors affecting the moisture content of litter such as nutrition, drinker type and management, environmental conditions (e.g., temperature, relative humidity, ammonia levels, ventilation rate), and flock health. This review addresses footpad dermatitis characteristics, causes, and the assessment system to provide a guide for future research.

Validation of the Complementary Relationship of Evapotranspiration Hypothesis Using In-situ Measurements (관측자료 기반의 용담댐 유역 증발산 보완관계 가설 검증)

  • Eunji Kim;Boosik Kang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.264-264
    • /
    • 2023
  • 물순환 과정에서의 증발산은 장기적인 관점에서의 수자원 계획 수립 시 중요한 요소이다. 증발산은 기온, 상대습도, 일사량 등 기상학적 인자뿐만 아니라 증발표면, 식생분포 등 다양한 인자의 복합작용에 의해 일어나므로, 유역 단위에서 발생한 실제증발산(Actual evapotranspiration, AET)을 측정하기에는 기술적인 한계가 존재한다. 그러나 증발산 보완관계(Complementary relationship of evapotranspiration, CRE) 가설을 활용하면, 수문요소의 상호작용을 고려한 모델링을 거치지 않고도, 비교적 간단하게 AET를 추정할 수 있다. 본 연구는 증발산 관측자료를 기반으로 유역 단위에서의 CRE를 검증하고자 하며, 플럭스 타워 등 다양한 관측장비가 설치되어 있는 용담댐 시험유역을 대상유역으로 선정하였다. 용담댐 유역 내 산지에 위치한 덕유산 플럭스 타워에서 측정된 증발산을 AET로 보았으며, 유역 인근에 위치한 전주 기상관측소에서 측정되는 팬 증발량(Epan)을 잠재증발산량(Potential evapotranspiration, PET)으로 보았다. Epan 계측시, 증발팬의 가열 등 주변환경 변화로 인해 과다하게 추정되는 값을 보완하기 위해 FAO Penman-Monteith 식을 활용해 팬 증발량 보정계수(Coefficient of pan evaporation, kp)를 산정하여 적용하였다. 습윤증발산량(Wet evapotranspiration, WET)은 대기가 완전히 포화되었을 때 발생하는 증발산량으로, 댐 수표면에서 계측되는 수면증발량을 WET로 보았다. CRE 검증을 위해 AET와 PET를 각각 WET로 나누어 AET+와 PET+로 무차원화하였으며, 습윤지수(Moisture Index, MI)는 AET를 PET로 나누어 산정하였다. CRE 가설은 MI에 따른 AET+와 PET+가 서로 보완관계를 갖는다는 것인데, 용담댐 유역의 관측자료를 활용하여 CRE를 검증한 결과 AET+와 PET+ 간의 비대칭계수(b)가 1.23인 것으로 나타났다. 이 때의 평균제곱오차(MSE)는 0.599, 결정계수(R2)는 0.631로 나타나 CRE의 b가 적합하게 추정된 것으로 판단된다. 본 연구결과와 같이 검증된 CRE를 통해 증발산 관측지점이 없거나, 조밀하지 않은 유역의 AET를 간접추정할 수 있으며, 이를 활용해 보다 정확한 댐의 장기유출 모의와 용수공급계획 수립에 도움을 줄 수 있을 것으로 기대된다.

  • PDF