• Title/Summary/Keyword: 스텐트재협착

Search Result 35, Processing Time 0.02 seconds

Occurrence and Prognosis for the Thrombosis in the Drug-Eluting Stents and Bare-Metal Stents (약물 용출 스텐트와 일반 금속 스텐트에서 혈전증에 대한 발생과 예후)

  • Kim, In-Soo;Choi, Nam-Gil;Jang, Seong-Joo;Han, Jae-Bok;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.273-283
    • /
    • 2012
  • Drug-eluting stents (DES) have significantly reduced in-stent restenosis, compared to bare-metal stents (BMS). However, there remains concern for the increased risk of stent thrombosis (ST) associated with DES. The present study sought to evaluate the incidence, clinical characteristics and outcome of ST in patients with acute myocardial infarction (MI) during a 1-year follow-up. 80 patients who developed ST were divided into 2 groups according to stent type: group I (DES-ST, n = 57 ) and group II (BMS-ST, n = 23 ). There were no differences between group I and II in the overall incidence of ST (2.7% vs. 4.3%, p=0.064) and in the incidence of each type of ST: acute ST (8.8% vs. 2.3%), subacute ST (50.9% vs. 60.9%), late ST (19.3% vs. 8.7%), and very late ST (21.1% vs. 17.4%) (p=0.605). Predictors of 1-year mortality were the occurrence of ST (OR 8.12, 95% CI 2.83-23.61, p<0.001), left ventricular ejection fraction<40% (OR 6.41, 95% CI 2.42-16.96, p<0.001), and age${\geq}$75 years (OR 4.98, 95% CI 1.95-12.74, p=0.001).

Stent Design Using Computational Fluid Dynamics (전산유체역학을 이용한 스텐트 설계)

  • Kim, Tae-Dong;Barakat, Abdul;Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1042-1048
    • /
    • 2005
  • Numerical investigation has been made on the stent design to minimize the neointimal hyperplasia. Computational fluid dynamics is applied to investigate the flow distributions in the immediate vicinity of the given idealized stent implanted in the blood vessel. Parametric study on the variations of the number of stouts, stent diameters, stent spacings and Reynolds numbers has been conducted using axi-symmetric Navier-Stokes equations. An initial difficulty in the study is to determine the optimal stent design to understand the flow physics of the flow disturbance induced by stent. The size of recirculation zone around stent is depend on the stent diameter, number of stent wire and Reynolds number but is insensitive to the stent wire spacing. It is also found that when the flow is in acceleration, the flow sees a more favorable pressure gradient, and the separation zones are smaller than the steady flow case. When the flow is in deceleration and the flow sees a more adverse pressure gradient so that the separation zones are larger.

Numerical Analysis on the Effect of Wall Shear Stress Around the Ring Drug-Eluting Stent (고리형 약물분출 스텐트 주위 벽전단응력의 영향에 대한 수치해석)

  • Seo, Tae-Won;Barakat, Abdul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.21-28
    • /
    • 2007
  • The use of drug-eluting stents has dramatically reduced the incidence of restenosis however, much remains to be teamed about the performance of these stouts. In the present study, we tested the hypothesis that the design of drug-eluting stents influences the efficacy of local drug delivery to the arterial wall and that this effect depends on both arterial geometry and the prevailing flow conditions. We performed computational simulations in which the coupled Navier-Stokes and advection-diffusion equations were solved to determine the flow field and drug concentration in the vicinity of model drug-eluting stouts It is found that the characteristics of flow phenomena can be influenced greatly by the ratio of stent diameter to vessel diameter. The presence of drug-eluting stent may have profound effect on wall shear stresses, recirculation sizes and drug distributions. The results show that recirculation zone is influenced by the imposed flow conditions and stent diameter. In pulsatile flow, the low wall shear stress and high drug concentration occur along the arterial wall during the decelerating flow conditions. These results could provide the guideline for future drug-eluting stent designs toward reducing restenosis by affecting local wall shear stress distributions associated with neointimal hyperplasia.

Role of Catechol in the Stability of Biocoating Materials in Wet Environment (바이오 코팅 재료의 습윤 안정성에 대한 카테콜 작용기의 역할)

  • Lee, Damjung;Lee, Kyueui
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.216-221
    • /
    • 2022
  • Biocompatible polysaccharide coating technology can be a promising solution to overcome unexpected diseases caused by inflammatory reactions of metallic biomaterials (e.g., stent restenosis, etc.). However, due to their inherent hydrophilicity, it is difficult to maintain the coating layer for a long time in the physiological wet-environment. Herein, catechol functionalized hyaluronic acid was synthesized and introduced to the polymeric stent (polylactic acid) as the adhesive biocoating material. Surprisingly, even with the low degree of substitution of catechol (1.26%), a significant improvement in the underwater stability was observed, confirmed by capillary experiments and spectroscopic analysis. Our results may provide an insight into the positive role of catechol molecular adhesive group in the in-vivo stability of biocoating materials.

Surgical Management of Idiopathic Tracheal Stenosis -Three case reports- (특발성 기관 협착증(Idiopathic Tracheal Stenosis)의 외과적 치험 -3예 보고-)

  • Kim, Hyung-Tae;Choi, Ho;Yoon, You-Sang
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.439-443
    • /
    • 2003
  • A lower laryngeal and upper tracheal stenosis that is of idiopathic origin is occasionally seen. It is called an idiopathic tracheal stenosis. These circumferential fibrous stenosis is rare and they are most often located in the subglottic larynx and extend to varying distances predominantly in young women. Because of the unknown nature of the disease process and uncertainty about its future progression, patients were approached conservatively. Recently, surgical resection and reconstruction have been increasingly performed, as favorable results were obtained. Three female patients with dyspnea were admitted. For two patients, they were diagnosed this conditions as bronchial asthma by mistake. All patients were performed computed tomography and bronchoscopy. For two patients with subglottic stenosis, subglottic resection was performed by cervical collar incision, and for the other one patient with distal tracheal stenosis, tracheal resection was performed by right posterolateral thoracotomy. A diagnosis of idipathic tracheal stenosis was confirmed by postoperatively pathologic finding. For one case, because of anastomosis site infection and restenosis, a whole tracheal exposure was performed by cervical collar incision and median sternotomy. And reoperation was peformed successfully.

Comparison of the One-year Follow-up Results after Coronary Bypass Surgery versus Percutaneous Coronary Intervention with Drug-eluting Stents in Patients with Left Main Coronary Artery Disease (좌주간지 병변에 대한 약물방출스텐트시술과 관상동맥우회수술의 1년 추적결과 비교)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Chung, Woo-Young;Chae, In-Ho;Choi, Dong-Ju
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.210-215
    • /
    • 2008
  • Background: Drug-eluting stents are contributing to the exponential growth of percutaneous coronary intervention, and even in the patients with left main coronary artery disease, owing to the decreased restenosis rate. Our study aimed at comparing the one-year results after coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents in patients with left main coronary artery disease. Material and Method: Those patients who underwent coronary bypass surgery or stenting at our hospital under the diagnosis of left main coronary artery disease were divided in two groups. The variables for comparison were the preoperative disease severity, the length of the hospital stay, the early mortality and the cumulative incidence of mortality, myocardial infarction and repeated revascularization. Result: There were 101 cases in the surgery group and 78 cases in the stent group. Age, gender, the risk factors, the left ventricular ejection fraction and the proportion of acute coronary syndrome showed no significant differences between the two groups. The surgery group showed a more severe condition according to the Euroscore, a greater incidence of urgency, a longer hospital stay and a greater incidence of multi-vessel disease. The early mortality and one-year cumulative mortality were not different between the groups. The Euroscore-matched comparison for the surgery group (41 patients) and the stent group (78 patients) showed no significant differences in the Euroscore, age, gender, risk factors and the proportion of acute coronary syndrome. The surgery group in the Euroscore-matched comparison showed more multi-vessel disease and a longer hospital stay. The surgery group showed lower early mortality and lower one-year cumulative mortality, but this was statistically insignificant (0% vs 2.6%, respectively, p=0.55; 0% vs 6.6%, respectively, p=0.30). The rates of repeated revascularization and major adverse events (death or myocardial infarct) were lower in the CABG group, but this was not statistically significant (13.3% vs 6.3%, respectively, p=0.48; 10.0% vs 0%, respectively, p=0.09). Conclusion: Percutaneous coronary intervention using drug-eluting stents in low-risk patients with left main coronary artery disease resulted in a shortened length of the hospital stay, as compared with that of the CABG group of patients. However, the patients who underwent percutaneous coronary intervention using drug-eluting stents showed a tendency for an increased rate of repeated revascularization and higher one-year cumulative mortality. Further studies with large populations and longer follow-up will be necessary to reaffirm our findings.

Effect of Drug Eluting Uniformity for Biodegradable Stent by Solid Freeform Fabrication (쾌속조형기법을 이용한 생분해성 스텐트용 메쉬필름의 약물방출거동 효과)

  • Cheong, Sin Young;Kim, Yang Eun;Koh, Young Joo;Shin, Wang Soo;Lee, Jun Hee;Kim, Wan Doo;Yoo, Young Eun;Park, Su A
    • Polymer(Korea)
    • /
    • v.38 no.1
    • /
    • pp.93-97
    • /
    • 2014
  • Biodegradable drug-eluting stent has dual functions of supporting the lumen and treating internal tumor preventing the restenosis by releasing drug. In this study, the polycaprolactone (PCL) based three dimensional (3D) mesh loaded with paclitaxel (PTX) was presented by rapid prototyping (RP) technique of solid freeform fabrication (SFF) for biodegradable drug-eluting stent application. PCL has many advantageous properties such as good biocompatibility, good mechanical properties, and good drug permeability. PTX is widely used in the cancer treatment by inhibiting tumor cell proliferation. Analytical methods of HPLC and NMR were used for simultaneous quantification of PTX. Scanning electron microscopy (SEM) was performed to observe the architecture and morphologies of 3D mesh. The cytotoxicity assay results indicated released PTX's biological activity. This study provided that PCL based 3D mesh loaded with PTX by RP technique has great potential for biodegradable drug-eluting stent application.

Metal Surface Coating Using Electrospray of Biodegradable Polymers and $\alpha$-Lipoic Acid Release Behavior for Drug-Eluting Stents (생분해성 고분자의 전기분사를 이용한 약물방출 스텐트용 금속표면 코팅 및 ALA방출 거동)

  • Kim, Dong-Min;Lee, Bong-Soo;Park, Cheol-Ho;Park, Kwi-Deok;Son, Tae-Il;Jeong, Myeong-Ho;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.178-183
    • /
    • 2010
  • Medical metal stents inserted to patients with a cardiovascular disease associated with coronary artery system have relatively increased the survival rate. The development of new stents is, however, urgently required due to restenosis and late thrombosis generated in metal stents. To solve these problems, the biodegradable polymers such as poly(lactide-co-glycolide) (PLGA), poly(L-lactide)(PLLA), and poly ($\varepsilon$-caprolactone)(PCL) were mixed with alpha lipoic acid (ALA), which is well known to inhibit the proliferation of neointimal hyperplasia. Subsequently, the ALA-loaded polymers were coated on stainless steel by electrospray. The drug-eluting behaviors from the coated polymers were investigated according to kinds and concentrations of polymers, spray rates, and kinds of solvents. The drug-eluting rate from PCL with the lowest glass transition temperature was the fastest among three polymers and followed by PLGA and PLLA. The surface roughness increased as the spray rate was increased and also the drug-eluting rate was affected by kinds of solvents with different boiling point. It is expected that drug-eluting stent (DES) coated with ALA-loaded polymers can be applied practically for clinical applications by controlling the behavior of drug release.

Hybrid Off-pump Coronary Artery Bypass Combined with Percutaneous Coronary Intervention: Indications and Early Results (심폐바이패스 없이 시행하는 관상동맥우회술과 경피적 관상동맥중재술의 병합요법 : 적응증 및 조기성적)

  • Hwang Ho Young;Kim Jin Hyun;Cho Kwang Ree;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.733-738
    • /
    • 2005
  • Background: The possibility of incomplete revascularization and development of flow competition after revascularization of the borderline lesion made the hybrid strategy as an option for complete revascularization. Material and Method: From January f998 to July 2004, 25 $(3.2\%)$ patients underwent hybrid revascularization among 782 total OPCAB procedures. Clinical results and angiographic patencies were evalulated. Percutaneous coronary intervention (PCI) was peformed before CABG in 8 patients and after CABG in 47 patients. Result: The causes of PCIs before CABG were to achieve complete revascularization with minimally invasive surgery (n=7) and emergent PCI for culprit lesion (n=1). The indications of PCIs after CABG were high possibility of flow competition in the borderline lesion of right coronary artery territory (n=8), diffuse atheromatous lesion preventing anastomosis of graft (n=5), severe calcified ascending aorta with no more arterial grafi available (n=3), and intramyocardial coronary lesion (n=1). Mean number of distal anastomoses was $2.3\pm1.0$. Mean number of lesions treated by PCI was $1.2\pm0.4$. There was no operative or procedure-related mortality. PCI-related complication was periprocedural myocardial infarction in one patient, and complications related to CABG were transient atrial fibrillation (n=5), perioperative myocardial infarction (n=1), and transient renal dysfunction (n=1). Early postoperative coronary angiography $(1.8{pm}1.6days)$ revealed $100\%$ patency rate of grafts (57/57). The stenosis occurred in one patient performed PCI before CABG, which was successfully treated with re-ballooning. During midterm follow-up (mean; $25{\pm}26$ months), 1 patient died of congestive heart failure. All survivors (n=24) accomplished follow-up coronary angiographics, which showed .all grafts (56/57) were patent except one string sign. In-stent restenosis was developed in 2 patients who received bare metal stents. Conclusion: In selected patients, complete revascularization was achieved with low risk by taking the hybrid strategy.

The Developing Trend of Cardiovacular Drug Coated Balloon Catheter (심장혈관용 약물코팅풍선카테터의 개발 동향)

  • Park, Junghun;Jo, Won-Il;Byeon, Dae-Heung;Kang, So Young;Nam, Choong-hyun;Seo, Kyoung-Woo;Park, Jun-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.545-550
    • /
    • 2022
  • As a result of the rapid entry into an aging society and westernized eating habits, the number of heart disease patients caused by angina pectoris, myocardial infarction, and high blood pressure has increased by more than 100,000 over five years. Heart disease has consistently ranked second in the cause of death in Korea over the past eight years, and medical expenses consumed annually reach 6 trillion won. While various treatments are being proposed for more patients, drug-coated balloon catheters have been developed and gradually commercialized to solve the disadvantages of stent implantation such as restenosis and increased risk of bleeding due to long-term double antiplatelet medication. In Korea, it began to use a drug-coated balloon catheter with the first release of it called "SeQuent Please (Bibrown Korea)" in 2010. Its demand increased gradually as insurance benefits were applied in 2012. Drug-coated balloon angioplasty is increasing in use not only in Korea but also around the world, especially in the Asia-Pacific region, including Japan. Until now, the demand for domestic products is increasing, and if the efficiency in vivo and clinical trials is proven in the future, it is expected to be an effective procedure compared to high-risk stent implantation.