• Title/Summary/Keyword: 스크류

Search Result 446, Processing Time 0.026 seconds

A study on the bone thickness of midpalatal suture area for miniscrew insertion (미니스크류 식립 부위로서 정중 구개봉합부 골의 두께에 관한 연구)

  • Kyung, Seung-Hyun
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.63-70
    • /
    • 2004
  • The midpalatal suture area has some advantages for supporting miniscrews : it has no specific anatomical structure, it is composed of thick cortical bone, and covered with attached gingiva. So it is suitable area for inserting miniscrews. However, the midpalatal suture area appears thinner when seen in ceph. As a result, Clinicians can misunderstand that inserting miniscrews cause the problem, both the risk of perforation and the decrease of stability. The purpose of this article is measuring the vertical bone thickness of the midpalatal suture area for inserting miniscrews. The total of 25patient (male : 13, female : 12), who are in their twenties, were taken CT. The vertical bone thickness of the midpalatal suture area was measures from the transverse section of CT. As a result, We reached a conclusion from the differences of each area. It is as follows: 1. There is no significant difference between the thickness of male group and that of female group. 2. In coronal section, Bone thickness becomes thinner from the midpalatal suture to Left & Right side, in sagittal section, Bone thickness becomes thinner from incisive foramen to PNS. 3. The area that is within 3mm of left and right from the midpalatal suture area transversely and within 25mm backward from the incisive foramen sagittaly is enough for inserting miniscrews.

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

Miniscrew Installation Area and Condition on Maxillary Palatal Side (상악구개측 미니스크류 식립위치 및 조건)

  • Lee, Ki-Yeon;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.61-71
    • /
    • 2009
  • Anchorage control is important in orthodontic treatment. Recently miniscrew is widly used as maximum anchorage in orthodontic treatment, and then it is important to install miniscrew safely without damaging adjacent anatomic structure. In a view of Miniscrew's stability, maxilla is unfavorable than mandible, and moreover maxillary soft buccal bone has disadvantage on stability. so palatal area comes into notice for installation area. We measured distance between palatal roots and bone thickness at midpalatal area using 3D computed tomography, and have found following results. 1. On the comparison of distance between palatal roots, the distance between 2nd premolar and 1st molar was significantly longest and the distance between premolars was significantly shortest. 2. Going toward lateral area from midpalatal suture and posterior area from zero point, bone thickness significantly became shorter and shorter. And 5.0mm palatal sagittal plane has more significance decrease of bone thickness than 2.5mm palatal sagittal plane. According to these results, we can conclude that the palatal installation of miniscrew between 2nd premolar and 1st molar is safest. And it is more safe that comes closer to midpalatal suture and to anterior area in regard to incisive canal.

Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery (마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향)

  • Mai, Hai Yen;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.219-224
    • /
    • 2019
  • Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (${\alpha}=.05$). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of micro-screw for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

Development of Screw-Type Handy Earth Auger for an Improved Digging Efficiency(I) - Design and Manufacture - (토양굴취력이 향상된 스크류형 경량 식혈기 개발(I) - 설계 및 제작 -)

  • Kim, Jin Hyun;Lee, Jae Hyun;Kim, Ki Dong;Ko, Chi Woong;Kim, Dong Geun
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.31-41
    • /
    • 2016
  • This study was conducted to develop a handy earth auger for use in sloppy and rugged forest terrains in order to reduce labor cost which comprises a major part of the production costs in forest afforestation projects. The first prototype is developed consist of two parts, the soil-digging screw and the battery power source. The specifications of the first prototype screw are: length of 170mm, a top diameter of 60mm, bottom diameter of 47mm, 23° angle for each helix, and a 50mm awl-head tip. The use of a single line of screw was selected for reduced weight. In addition, a power source of rotary DC Motor(WD-6G2425, WONILL, Korea) with a maximum torque of 30kgf-cm, rotation of 20-30rpm, K6G30C decelerator with a reduction ratio of 30:1 which could be used with no load for 48 was operated. In consideration of its weight, a lithium battery was utilized in line with the goal of developing a lightweight auger. In order to evaluate the performance of the first prototype, test sites were selected as 6 areas. The rotational force was found to be highest in area A(Solid area), followed by areas F(Mounted slope 40° area) and E(Mounted slope 30° area). It was also observed that in general, the rotational force increased along with the increase in soil depth with the maximum rotational force recorded at 10cm.

Analysis of Jacobian and Singularity of Planar Parallel Robots Using Screw Theory (스크류 이론을 이용한 평면형 병렬로봇의 자코비안 및 특이점 해석)

  • Choi, Jung-Hyun;Lee, Jeh-Won;Lee, Hyuk-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.11
    • /
    • pp.1353-1360
    • /
    • 2012
  • The Jacobian and singularity analysis of parallel robots is necessary to analyze robot motion. The derivations of the Jacobian matrix and singularity configuration are complicated and have no geometrical earning in the velocity form of the Jacobian matrix. In this study, the screw theory is used to derive the Jacobian of parallel robots. The statics form of the Jacobian has a geometrical meaning. In addition, singularity analysis can be performed by using the geometrical values. Furthermore, this study shows that the screw theory is applicable to redundantly actuated robots as well as non-redundant robots.

A Study on Thermoplastic Elastomer Blend Using Waste Rubber Powder(I): Screw Configurations, Morphologies and Mechanical Properties (폐고무 분말을 이용한 TPE 블렌드에 관한 연구(I) : 스크류 조합, 모폴로지, 기계적 물성)

  • Lee, Sung-Hyo;Hwang, Sung-Hyuk;Kim, Jin-Kuk
    • Elastomers and Composites
    • /
    • v.36 no.2
    • /
    • pp.86-93
    • /
    • 2001
  • For solving the environmental problem of the waste EPDM and for new TPE blend materials, we developed a new kind of TPE material using a co-rotating twin screw extruder. To improve the mechanical properties of TPE material such as tensile strength, elongation at break, and modulus of the blend, PP and waste EPDM powder were blended with different screw configurations. The mechanical properties of the blends and morphology of the TPE were investigated. As the number of kneading disc and left-handed screw element increased, dynamic vulcanization of the material was increased because the shear stress and residence time of blends increased.

  • PDF

A study on the treatment of anterior open bite with midpalatal miniscrews (정중구개부 미니스크류를 이용한 개방교합치료에 대한 연구)

  • Kyung, Seung-Hyun
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.13-21
    • /
    • 2004
  • Recently several techniques have been reported for the treatment of anterior open bite in adults characterized by molar intrusion with skeletal anchorage. In this study, five adult patients who had anterior open bite malocclusion were selected to undergo upper molar intrusion with midpalatal miniscrew to close the open bite. The aim of this study is (1) to validate true intrusion of molars in adults (2) to test the usefullness of midpalatal miniscrews as anchorage for intruding upper molars (3) to evaluate the skeletal and dental changes of open bite closure. The results are as follows. (1) All had true intrusion of the maxillary molars. Mean amount of molar intrusion was 3.4mm(range 1.5-5mm). (2) No movement of midpalatal miniscrew occurred during their use. (3) Open bite closure was achieved for all 5 patients. The mandible closed and B-point rotated anteriorly and upward. The mandibular plane angle and the occlusal plane angle decreased.

A Study on Physical Dechlorination of Mixed Plastics using Screw Reactor (스크류반응기를 이용한 흔합플라스틱의 물리적 탈염소에 관한 연구)

  • Kim Sang-Guk;Eom Yujin;Chung Soo-Hyun
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.20-27
    • /
    • 2006
  • PVC is the thermoplastic offering excellent material properties. PVC has been used in wide variety of applications, however, it causes environmental problems when it is discarded because of its high chlorine content. Since dechlorination reaction of PVC is taking place at relatively low temperature compared to the pyrolysis temperature of plastics, study on the dechlorination reaction has been carried out as a pre-treatment process. Twin screw reactor which shows excellent mixing capabilities is employed. Experimental variables are the first and second reactor temperature, PVC content in mixed plastics, viscosity of mixed plastics, feeding rate, rotational speed or the second reactor. Over $90\%$ of dechlorination ratio can be obtained under proper operation conditions. Chlorine gas evolved from reactor is absorbed in water and can be recovered as a hydrochloric acid. Analysis had been done on chlorine flows by taking material balance over realtor.

A Study on Physical Dechlorination of Mixed Plastics using Screw Reactor (스크류반응기를 이용한 혼합플라스틱의 물리적 탈염소에 관한 연구)

  • Kim, Sang-Guk;Eom, Yu-Jin;Chung, Soo-Hyun
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.83-96
    • /
    • 2005
  • PVC is the thermoplastic offering excellent material properties. PVC is used in wide variety of applications, however, it causes environmental problems when it is discarded because of its high chlorine content. Since dechlorination reaction of PVC is taking place relatively low temperature compared to the pyrolysis temperature of plastics, study on the dechlorination reaction has been carried out as a pre-treatment process. Twin screw reactor which shows excellent mixing capabilities is employed. Experimental variables are first and second reactor temperature, PVC content in mixed plastics, viscosity of mixed plastics, feeding rate, rotational speed of the second reactor. Over 90% of dechlorination rate can be obtained under proper operation conditions. Chlorine gas evolved from reactor is absorbed in water and can be recovered as a hydrochloric acid. Analysis had been done on chlorine flows by taking material balance over reactor.

  • PDF