• Title/Summary/Keyword: 순음청력역치

Search Result 21, Processing Time 0.02 seconds

A Comparison of Pure-Tone Thresholds to the Pre and Post Fogging after Refractive Correction in Normal Eyes (굴절교정된 정상안에서 운무 전후에 따른 순음청력역치의 비교)

  • Cho, Soo-Jin;Joo, Seok-Hee;Lee, Koon-Ja;Choi, In-Sil;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.89-93
    • /
    • 2009
  • Purpose: To purpose of this study was the pure-tone audimetry changes to compare pre and post fogging after visual correction in normally hearing adults. Methods: The estimated that no ocular and audiolar disesases, we selected (male: 30, female: 20) in corrected visual acuity over the 1.0 eye. Pre and post fogging were measured using the pure-tone audimetry. Results: To compared fre and post fogging, fre fogging was higher than fre fogging. The take value were just about every kind of Hz but 200 Hz, respectively which were statistically significant (p<.05). Low Hz area in 250 and 500 Hz were 6.8${\pm}$8.4dBHL, 4.3${\pm}$6.6dBHL, there is not all the difference between any other area, 2000 Hz in the middle Hz area was 0.8${\pm}$4.5dBHL. Conclusions: The study presents different results of measurements in within normal limits. we thought that pure-tone thresholds to the pre and post fogging after refractive correction in normal adults and would be used basic data.

  • PDF

The Correlation Between Speech Reception Threshold and Pure Tone Audiometry (어음청취역치와 순음청력검사의 상관관계에 관한 연구)

  • 이철희;선우대활;민양기;백만기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.2-39
    • /
    • 1981
  • Speech reception threshold is a base for word discrimination testing, but it also serves as a check for the reliability of pure tone audiogram. In order to investigate the correlation between SRT and PTA these tests were carried out in patients with conductive hearing loss and normal hearing, using Grason-Stadler 1702 Audiometer. The results were as follows; 1) The difference between the scores of SRT and PTA's was 2.4 dB with a range of -3.3 dB∼+8.3 dB in conductive hearing loss, and was 1.9 dB with a range of -6.7 dB∼+5 dB in normal hearing group. 2) The difference between the scores of SRT and each speech frequency of PTA was 6 dB at 500 Hz, 3 dB at 1,000 Hz and 8.8 dB at 2,000 Hz in conductive hearing loss, and 3 dB at 500Hz, 2 dB at 1,000Hz, and 5dB at 2,000Hz in normal hearing group.

  • PDF

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

Influence of stress and pure tone audiometry on noise-exposed dental laboratory technicians by dental instrument (치과기공 소음 노출이 치기공과 학생의 스트레스와 순음청력에 미치는 영향)

  • Yon, Jung-Min;Lee, Ju-Hee;Kim, Dae-Hyun;Lee, Og-Kyoung
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.363-370
    • /
    • 2016
  • Noise is unwanted sound that is the reason of the stress and hearing loss. The current study attempted to estimate whether the noise of dental laboratory affected stress and pure tone audiometry (PTA) of dental laboratory technicians (DLTs) using heart rate variability, air and bone conduction audiometry. The age, heights, and weights of DLTs were resembled control. Standard deviation of normal to normal interval such as stress resistance and normalized HF of DLTs were significantly decreased, but heart rates, normalized LF, and LF/HF ratio of DLTs were significantly increased compared with control. In air conduction audiometry of DLTs, significant increments of thresholds encountered in 125, 250, 500, 1000, 2000, 3000, 4000, and 6000 Hz in the right ears and 125, 250, 500, 1000, and 2000 Hz in the left ears. Thresholds of bone conduction audiometry in both ears were significantly increased in 250, 500, 1000, 2000, and 4000 Hz. The findings in this study provide that stress and hearing loss observed in noise-exposed DLTs at dental laboratory. Therefore, proper safety precautions should be carried out at dental laboratory.

The Study on Method of Speech Audiometry and the Korean Word Lists Part 1 : Normal Hearing Group (어음청력점사방법과 한국어음청력검사표에 관한 연구)

  • 김기령;김영명;최생이;강대령;심윤주
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.6.1-6
    • /
    • 1977
  • Among the various audiometric test batteries, pure tone and speech audiometry was carried as routine. During the past 20 years, there have been works on speech word list for Korean language. As a preliminary work for standardization of Korean speech word list, the authors are intended to study on the factors of test methods with these proposal speech word lists. Now, authors has studied as followings methods and materials and the results were obtained as followings. A. Materials and Methods a. Word List 1. Paik Chun Kee (Paik) 2. Soh Jin Myoung (Soh) 3. Cynn Kyu Shik (Cynn) 4. Lee Jong Dam (Lee) 5. Hahm Tae Young (Hahm) b. Test Method 1. ascending 2. descending c. Test Material 1. live voice 2. Recorded male voice 3. Recorded female voice B. Results 1. Score of ascending method was better result than descending method. 2. Speech reception threshold and discrimination score were better in recorded female voice, live voice and recorded male voice in that order. 3. Speech reception thresholds among tested word lists were Hahm, Lee, Soh, Cynn and Paik in that order. 4. Discrimination score was highest with Cynn and Lee, Soh, Hahm, Paik in that order.

  • PDF

Evaluation of Puretone Threshold Using Periodic Health Examination Data on Noise-exposed Workers in Korea (소음 특수건강진단 자료를 이용한 순음청력검사 평가)

  • Kim, Yang-Ho;Choi, Jung-Keun;Park, Jung-Sun;Moon, Young-Han;Kim, Kyoo-Sang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.1
    • /
    • pp.30-39
    • /
    • 1999
  • Objectives. This study was carried out to evaluate hearing impairment judgement and to investigate the differences in various diagnostic criteria for noise-induced hearing loss (NIHL) among workers who required for close observation (C). Methods. Out of 731,029 workers who had taken the specific periodic health examination in 1994, we used the audiometric data on 37,999 workers (C) eliminating the employees who had previous otologic problems. Many investigators have being using different criteria for the evaluation of hearing impairment. In this study, we used the criteria of early (1989-1994), current, compensation for NIHL in Korea, 2-, 3-, 4-divided classification and hearing loss at 4,000 Hz and compared the evaluation results. Results. The prevalences of C and workers who had occupational disease $(D_1)$ diagnosed for NIHL were 11.1 % and 0.44 %. There were significant difference in the prevalences of C and $D_1$, depending on different province of Korea. Pure tone averages (PTAs) were not appropriately applied in their evaluation 97% of workers whom we studied on were below the level of mild hearing loss judged by ISO standard. However, there were wide variations in the prevalence rate of mild hearing loss by diagnostic criteria. Thus, there were different judgements in determining the degree of NIHL depending on which diagnostic criteria were utilized. PTAs were found 20.54 (Rt) and 20.74 (Lt) when the method of 3-divided classification was applied for audiometric data. The degree of hearing impairment of the left ear was more severe than that of right ear. The prevalence of normal hearing threshold below 20 dB was 75.4% and the range of difference in both ear was below 10 dB. Right sided hearing threshold levels were 21.08 dB (500 Hz), 18.44 dB (1,000 Hz), 22.09 (2,000 Hz) and 52.36 dB (4,000 Hz). There was typical high frequency loss (C5-dip at 4,000 Hz) above 30 - 40 dB in normal hearing level. The increasing trend in hearing threshold level was gradually decreased by the increase of PTAs. The difference between PTAs and threshold at 4,000 Hz was about 10 dB. Conclusions. We could found that PTAs in the previous examination were not appropriately evaluated. This study revealed that they did not use unique criteria for managing the workers of NIHL. For the prevention of NIHL, it was found that the quality control on diagnosis and comprehensive management program were required, especially for those of hearing loss (C).

  • PDF

Development of Automatic Calibration System for PC-Based Pure Tone Audiometer (PC 기반 순음청력검사기를 위한 자동보정시스템 개발)

  • Kim, Jin-Dong;Kang, Deok-Hun;Song, Bok-Deuk;Lee, Il-Woo;Kong, Soo-Keun;Kwon, Soon-Bok;Jeon, Gye-Rok;Shin, Bum-Joo;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2586-2594
    • /
    • 2010
  • A pure tone audiometer should be able to produce both pure tone and masking noise with exact sound pressure level and frequency. For such purpose, it is unavoidable to periodically calibrates pure tone audiometer. However, manual acoustic calibration requires not only attention but also long time. It is possible to execute automatically calibration using software if it is PC-based pure tone audiometer. In this paper, we describe auto-calibration software for PC-based pure tone audiometer and dedicated sound level meter which has been implemented upon PC by us. To verify auto-calibration module, we examine whether output of PC-based audiometer calibrated through auto-calibration of this paper satisfies RETSPL of IEC or not.

Age- and Gender- Specific Reference Levels for Hearing Thresholds of Normal Aging in Korean (한국인의 정상적인 노화에 의한 성별 연령별 순음청력에 의한 기준청력)

  • Kim Sung Hee;Shin Jong Heon;Yeo Chang Ki;Han Young Kyung;Lee Jung Ki;Jarng Soon Suck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.6
    • /
    • pp.353-357
    • /
    • 2005
  • Declining auditory performance with advanced age is a well known and common problem that is becoming more Prevalent due to the increasing number of elderly people in our society. We introduce a novel ARCISM (Audiogram Result Computer Input. Save & Management software) data management program which enables the assessment of the risk of past history of hearing impairment on the basis of known risk factors. This study investigates the reference levels of pure tone hearing threshold of normal aging in Korean and the difference between fenders. The subjects were carefully selected by questionnaire and absence of any history of otologic infection, noise exposure. and ototoxic drug among 1603 subjects. who visited Health Promotion Center in Daegu Fatima Hospital for one year. The results show (1) hearing sensitivity declines with age. (2) higher frequency shows steeper slope of hearing declines than lower frequency. and (3) there were more hearing loss at 4 and 8 kHz in men than in women. Due to the ARCISM program. it was possible to manage huge data of hearing results and to obtain the reference level of a9e-related hearing declines. Furthermore, we expect that the results of this study can be the fundamental data for hearing rehabilitation for the elderly and for developing suitable hearing aids for Korean.

Development of Auto-Masking Puretone Audiometer supporting Multiple Modes (다중모드 지원 자동차폐 순음청력검사 시스템 개발)

  • Kim, Jin-Dong;Shin, Bum-Joo;Jeon, Gye-Rok;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1229-1236
    • /
    • 2009
  • Puretone audiometer, which is a machine used for measuring the minimum hearing threshold, can be cost-effectively implemented using computer with sound card and software. In this paper, we describe a puretone audiometer which has been designed and implemented based on a general PC with sound card. It supports air conduction and bone conduction test taking with automatic masking. It also provides multiple modes consisted of self-test, auto-test and manual test mode. Such multiple modes makes it possible to use in various environments like as home and/or hospital. Through measure of waveform of output voltage and sound pressure, we verified that puretone audiometer of this paper properly operates.

Characteristics of Noise Induced Hearing Loss of Fishermen Visiting a General Hospital (일개 종합병원을 방문한 어선원에서 발생한 소음성 난청의 특징)

  • You Sun Chung;Chang Hoi Kim
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.1
    • /
    • pp.41-49
    • /
    • 2023
  • Objectives: To obtain audiologic basic data to diagnose the noise induced hearing loss of workers in fisheries. Methods: The charts of the referred fishermen with noise induced hearing loss from November 2022 to February 2023 at a general hospital were retrospectively reviewed. Pure tone audiometry, speech audiometry, auditory brainstem response test and auditory steady state response test were conducted. Results: All of them were men over 60 years of age, and the average duration of exposure to noise was 38.9 ± 10.8 years, and the average symptom duration of hearing loss was 13.4 ± 4.3 years. Although the hearing thresholds in the high frequencies were higher than thresholds in the low frequencies, the audiogram showed a down-sloping pattern without rebound at 8 kHz. 10.5% of the cases had thresholds greater than 75 dB in high frequencies, but 57.9% had thresholds greater than 40 dB in low frequencies. Other hearing test results of fishermen were similar to those of general noise-induced hearing loss. Conclusions: Although the fishermen were exposed to noise for a long time, they recognized hearing loss late. The hearing threshold in lower frequencies of the fishermen was higher than expected. Further studies will be needed to analyze the audiologic characteristics of noise-induced hearing loss of the fishermen after confirming noise exposure by conducting a survey on the working environment, such as the noise level and working hours.