• Title/Summary/Keyword: 순음청력검사

Search Result 41, Processing Time 0.034 seconds

Development of Auto-Masking Puretone Audiometer supporting Multiple Modes (다중모드 지원 자동차폐 순음청력검사 시스템 개발)

  • Kim, Jin-Dong;Shin, Bum-Joo;Jeon, Gye-Rok;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1229-1236
    • /
    • 2009
  • Puretone audiometer, which is a machine used for measuring the minimum hearing threshold, can be cost-effectively implemented using computer with sound card and software. In this paper, we describe a puretone audiometer which has been designed and implemented based on a general PC with sound card. It supports air conduction and bone conduction test taking with automatic masking. It also provides multiple modes consisted of self-test, auto-test and manual test mode. Such multiple modes makes it possible to use in various environments like as home and/or hospital. Through measure of waveform of output voltage and sound pressure, we verified that puretone audiometer of this paper properly operates.

A Comparison of Pure-Tone Thresholds to the Pre and Post Fogging after Refractive Correction in Normal Eyes (굴절교정된 정상안에서 운무 전후에 따른 순음청력역치의 비교)

  • Cho, Soo-Jin;Joo, Seok-Hee;Lee, Koon-Ja;Choi, In-Sil;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.89-93
    • /
    • 2009
  • Purpose: To purpose of this study was the pure-tone audimetry changes to compare pre and post fogging after visual correction in normally hearing adults. Methods: The estimated that no ocular and audiolar disesases, we selected (male: 30, female: 20) in corrected visual acuity over the 1.0 eye. Pre and post fogging were measured using the pure-tone audimetry. Results: To compared fre and post fogging, fre fogging was higher than fre fogging. The take value were just about every kind of Hz but 200 Hz, respectively which were statistically significant (p<.05). Low Hz area in 250 and 500 Hz were 6.8${\pm}$8.4dBHL, 4.3${\pm}$6.6dBHL, there is not all the difference between any other area, 2000 Hz in the middle Hz area was 0.8${\pm}$4.5dBHL. Conclusions: The study presents different results of measurements in within normal limits. we thought that pure-tone thresholds to the pre and post fogging after refractive correction in normal adults and would be used basic data.

  • PDF

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

The Study on Method of Speech Audiometry and the Korean Word Lists Part 1 : Normal Hearing Group (어음청력점사방법과 한국어음청력검사표에 관한 연구)

  • 김기령;김영명;최생이;강대령;심윤주
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.6.1-6
    • /
    • 1977
  • Among the various audiometric test batteries, pure tone and speech audiometry was carried as routine. During the past 20 years, there have been works on speech word list for Korean language. As a preliminary work for standardization of Korean speech word list, the authors are intended to study on the factors of test methods with these proposal speech word lists. Now, authors has studied as followings methods and materials and the results were obtained as followings. A. Materials and Methods a. Word List 1. Paik Chun Kee (Paik) 2. Soh Jin Myoung (Soh) 3. Cynn Kyu Shik (Cynn) 4. Lee Jong Dam (Lee) 5. Hahm Tae Young (Hahm) b. Test Method 1. ascending 2. descending c. Test Material 1. live voice 2. Recorded male voice 3. Recorded female voice B. Results 1. Score of ascending method was better result than descending method. 2. Speech reception threshold and discrimination score were better in recorded female voice, live voice and recorded male voice in that order. 3. Speech reception thresholds among tested word lists were Hahm, Lee, Soh, Cynn and Paik in that order. 4. Discrimination score was highest with Cynn and Lee, Soh, Hahm, Paik in that order.

  • PDF

The Correlation Between Speech Reception Threshold and Pure Tone Audiometry (어음청취역치와 순음청력검사의 상관관계에 관한 연구)

  • 이철희;선우대활;민양기;백만기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.2-39
    • /
    • 1981
  • Speech reception threshold is a base for word discrimination testing, but it also serves as a check for the reliability of pure tone audiogram. In order to investigate the correlation between SRT and PTA these tests were carried out in patients with conductive hearing loss and normal hearing, using Grason-Stadler 1702 Audiometer. The results were as follows; 1) The difference between the scores of SRT and PTA's was 2.4 dB with a range of -3.3 dB∼+8.3 dB in conductive hearing loss, and was 1.9 dB with a range of -6.7 dB∼+5 dB in normal hearing group. 2) The difference between the scores of SRT and each speech frequency of PTA was 6 dB at 500 Hz, 3 dB at 1,000 Hz and 8.8 dB at 2,000 Hz in conductive hearing loss, and 3 dB at 500Hz, 2 dB at 1,000Hz, and 5dB at 2,000Hz in normal hearing group.

  • PDF

A Study on a Hearing Test to Measure Progress of Noise Induced Hearing Loss (소음성 난청 진전도 측정을 위한 청력측정법에 관한 연구)

  • Kwon, Hyung-Jun;Lee, Sung-Tae;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3
    • /
    • pp.184-190
    • /
    • 2010
  • Lowering of auditory caused by noise is increased, these days. Especially, people who have noise induced hearing loss by permanent exposure to noise are increased according to spread out of multimedia and improvement of information equipment. The pure tone audiometry used in the hospital presently inspect auditory manually up to 8,000 Hz bandwidth. So the case of noise induced hearing loss which suffered from extended high frequency over 8,000 Hz, there is a problem to prevent hearing loss by precognition. In this paper, we proposed a method to prevent noise induced hearing loss by using extended high frequency bandwidth from 12,000 Hz to 20,000 Hz. We have got a experimental result to fifty of twenties who are often used to earphones through portable equipment. As a result, 36% of twenties show lowering of auditory caused by noise and 2% of them shows severe loss of hearing.

순음청력검사

  • Kim, Gyu-Sang
    • KOREAN ASSOCIATION OF OCCUPATIONAL HEALTH NURSES
    • /
    • v.13 no.3 s.48
    • /
    • pp.16-23
    • /
    • 2006
  • PDF

Development of Linux based Real-Time Spectrum Analyzer for Puretone Audiometer (순음청력검사기를 위한 리눅스 기반 실시간 스펙트럼 분석기 개발)

  • Kang, Deok-Hun;Shin, Bum-Joo;Jeon, Gye-Rok;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2830-2839
    • /
    • 2011
  • Because the puretone audiometer is an important medical instrument used to diagnose hearing loss, the IEC and ANSI has been published a specification with which audiometer should comply. This paper describes development of Linux based real-time spectrum analyzer which is dedicated to puretone audiometer. It can measure not only hearing level but also compliance of IEC standard for puretone audiometer such as frequency accuracy, harmonic distortion, pulsed tone, narrow band noise and linearity. We have verified our real-time spectrum analyzer through comparing to commercial product.