• Title/Summary/Keyword: 수치감쇠

Search Result 404, Processing Time 0.029 seconds

Vibration Control of the Framed Building Structures Using KGDS System with Isotropic Damping Devices (등방성 감쇠장치를 갖는 KGDS시스템을 활용한 라멘조 건물의 제진효과)

  • Hur, Moo-Won;Lee, Sang-Hyun;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.52-59
    • /
    • 2015
  • In this paper, the vibration control effect of the isotropic damping devices (so-called Kagome dampers) was investigated by applying the Kagome dampers to a 20-story frame structure apartment. A new Kagome Damper System (KGDS) composed of the dampers and supporting column was proposed and numerical analyses were performed to investigate the effects of stiffness ratio between controlled structure and supporting column, the damper size and the number of the dampers. The numerical analysis results of a structure with KGDS up to the third story showed that the stiffness ratio should be higher than 6.4 and the damper size be at least $700{\times}700mm$ to effectively reduce the base shear and the maximum drift of the uppermost story. When the KGDS was installed up to the fifth story, the stiffness ratio should be higher than 7.0 and damper size needs to be at least $500{\times}500mm$ for obtaining the target performance.

Comparison of Fragility Using Natural Frequency and Damping Parameter in System (고유주파수와 감쇠비에 대한 시스템 손상도 비교)

  • Lee, Seok-Min;Jung, Beom-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.48-55
    • /
    • 2018
  • The purpose of the present study is to compare the reduction rate of natural frequency and the increase rate of damping parameter with structural damage in system. For this purpose, experiment and numerical simulation analysis are performed for the 2-span H-Beam with lower natural frequency and higher damping parameter from free vibration in structure. The response signal by impact load before and after damage is analyzed at 14 locations. The response signals for all locations are performed fast fourier transform to estimate the natural frequency reduction rate and wavelet transform to estimate the damping parameter increase rate. The time domain function corresponding to each scale(frequency) is separated from the response signal by wavelet parameter. The estimation of damping parameter increase rate using wavelet transform is more sensitive than the estimation of natural frequency reduction rate in structure.

Integrated Optimum Design and Cost Effectiveness Evaluation of Viscoelastically Damped Building Structures based on Life-Cycle Cost Minimization (생애주기비용 최소화에 의한 점탄성감쇠기 장착 빌딩구조물의 통합최적설계 및 비용효율성 평가)

  • Park, Kwan-Soon;Hahm, Dae-Gi;Koh, Hyun-Moo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.2 s.42
    • /
    • pp.17-27
    • /
    • 2005
  • This paper presents an integrated optimum design and a cost effectiveness evaluation method of a viscoelastically damped structural system. The criterion selected for the optimization is the minimization of the life?cycle cost which is a function of structural sizing variables and the amount of the viscoelastic damper. A genetic algorithm is used as a numerical searching technique in order to simultaneously find the optimum parameters of the integrated system. Optimal distributions of design variables according to various seismic characteristics are investigated by applying the proposed design method to a numerical example of a 10?story building structure. The cost effectiveness of viscoelastically damped structural system is also evaluated by comparing the life-cycle cost of the structure without viscoelastic dampers. The results show that the viscoelastic damper is effective in a region of low to moderate seismicity.

Seismic Response Control of Structures Using Decentralized Response-Dependent MR Dampers (분산제어식 응답의존형 MR 감쇠기를 이용한 구조물의 지진응답제어)

  • Youn, Kyung-Jo;Min, Kyung-Won;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.761-767
    • /
    • 2007
  • In centralized control system, complicated control systems including sensors, power supply and dampers should be required to satisfy the target response of large-scale structures. The practical applications of the centralized control system, however, is very difficult due to high order finite element model of structures, uncertainty of models, and limitations of the excitation system. In this study, the decentralized response-dependent MR damper of which magnetic field is automatically modulated according to the displacement or velocity transferred to the damper without any sensing and computing systems. this decentralized response-dependent MR damper are investigated according to the ranges of relative magnitude between the control force of MR damper and the story shear force of structures by nonlinear time history analysis. Finally, its performance is compared with centralized LQR algorithm which is used in general centralized control theory for a three story building structure.

A Study on the Noise and Vibration Damping Performance of RC Hollow Core Slab (중공형 RC 슬래브의 소음 및 진동 감쇠성능에 대한 연구)

  • Kim, Dong Baek;Kim, In Bae;Kim, Jong Hoon;Lee, Jae Won
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.292-300
    • /
    • 2019
  • Purpose: To reduce the noise and vibration of reinforced concrete slab structures, the damping performance is to be performed experimentally after installing hollow core or filling it with liquid. Method: Using the hollow rate as an experimental variable, the damping ratio and stiffness of each test specimen at impact load are obtained to determine the difference between the damping ratio and stiffness of the numerical analysis. In addition, the damping effects are reviewed by comparing the difference in the damping ratio and stiffness of a test specimen filled with liquid 50% of the study. Results: Since the difference in resistance between a specimen with or without hollow core is 5%, it is judged that there is no structural problem, and the injection of liquid into the hollow core can increase the damping ratio, which can reduce noise or vibration. Conclusion: At less than 20% of hollow rate, there was little damping effect, and at 30%, damping effect was found. However, if liquid is injected into the hollow core of the specimen, damping rate is shown to increase, and the injection of liquid into the hollow part is believed to reduce noise or vibration.

Reduction Effect for Deposition in Navigation Channel with Vegetation Model (식생모형에 의한 항로매몰 저감 특성)

  • Lee, Seong-Dae;Kim, Seong-Deuk;Kim, Ick-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.36 no.8
    • /
    • pp.659-664
    • /
    • 2012
  • Coastal vegetaion consists of rooted flowering marine plants that provide a variety of ecosystem services to the coastal areas they colonize. The attenuation of waves and sediments stabilization are often listed among these services. From this point of view, artificial vegetation model is an effective method of controlling sea bed and stabilization without damaging the landscape or the stability of the coastaline. In this study, numerical and hydraulic physical test for predicting deposition proces of a navigation channel caused by wave action is proposed. In the numerical model, we develop a numerical model for describing the wave attenuation and sediment transport in a navigation channel with a vegetation area. In addition, hydraulic model tests is performed in a navigation channel with irregular waves to examine the effect of vegetation in relation to deposition reduction in navigation channel. A comparison between the results of hydraulic and numerical tests shows resonable agreement.

Damping Characteristic of Resonator according to Geometry Variation (음향공 형상 변화에 따른 감쇠 특성 변화)

  • Kim, Jai-Ho;Park, Jin-Ho;Yu, I-Sang;Jang, Ji-Hun;Ko, Young-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.35-38
    • /
    • 2011
  • Damping characteristic according to acoustic cavity's geometries was investigated to control the high frequency combustion instability occurring in the Liquid Rocket Combustion Chamber by experimental test and linear analysis. Its diameter was determined as a design parameter and its orifice length and diameter were appointed as fixed parameter in this study. Result shows that the damping capacity has been almost constant through all the experiments despite using the same orifice and helmholtz resonators which have different volume.

  • PDF

Modal Parameter Extraction of Seohae Cable-stayed Bridge : II. Natural Frequency and Damping Ratio (서해대교 사장교의 동특성 추출 : II. 고유진동수와 감쇠비)

  • Kim, Byeong Hwa;Park, Jong-Chil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.641-647
    • /
    • 2008
  • This paper introduces a new technique that can extract natural frequencies and damping ratios from output-only vibration data. Firstly, the free vibration data is obtained from the cross correlations of the output-only response data using a singular value decomposition process. Secondly, the well-known system identification algorithm is applied to extract the natural frequencies and damping ratios from the extracted free vibration data. Comparing to ERADC technique, the accuracy of the proposed modal parameter identification algorithm has been numerically examined. Furthermore, the practicability of the proposed algorithm has been examined through the output-only acceleration data collected from the Seohae cable-stayed bridge. Using the proposed technique, total 24 modes have been identified for the deck plate motions of the bridge.

강지진동 분석의 최적화를 위한 고려요소

  • 이석태;조봉곤;이정모;조영삼
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.17-17
    • /
    • 2003
  • 한반도에 있어서의 지진의 영향을 분석하기 위해서는 강지진동 연구가 필수적이다. 강지진동 자료가 부족한 한반도의 특성상 모사를 통해 연구하고 있다. 강지진동 분석을 하기 위해서는 되도록 노이즈가 포함되어 있지 않은 지진파자료를 선택하여 그 지진자료의 스펙트럼 분석을 통해 감쇠상수 k, Q 등을 구한다. 이러한 감쇠상수 값을 통해 한반도의 진동 특성을 이해할 수 있다. 그러나 감쇠상수를 구하는 과정에서 감쇠상수 분석에 사용된 지진자료에 노이즈가 더해졌을 경우, 어떤 형태로 스펙트럼 영역에 영향을 미치고, 감쇠상수에는 어떤 영향을 미치는 지를 연구하여 노이즈효과를 제거할 수 있는 최적화된 분석에 관한 연구가 선행되어야 한다고 본다. 따라서 이번 연구에서는 강지진동 모사프로그램을 가지고 노이즈효과를 적용하면서 감쇠상수에 노이즈가 어떤 영향을 미치는 지에 대한 수치 해석적 연구를 실시하였다. 합성지진파에 이 합성지진파와 전혀 다른 주파수 형태를 보이는 노이즈를 강도를 달리하면서 합성해 본 결과, 노이즈효과를 고려할 수 있는 몇 가지 요소가 있음을 알 수 있었다. 감쇠상수 k값을 강지진동 모사프로그램으로부터 값을 달리하며 합성해 본 결과 노이즈효과를 보이는 것을 알 수 있었으며, 감쇠상수 k를 선형회귀를 통해 $k_{s}$$k_{q}$를 구할 때의 적용 주파수 범위를 변화시켰을 때도 일정한 양상의 노이즈 효과를 보였다. 또 지진자료와 노이즈를 중첩시킨 지진파 시계열 자료의 정부분만을 감쇠상수 k를 구하는 선형회귀에 이용했을 경우에도 노이즈 효과를 보였다. 또한 계산되어 나온 감쇠상수 값으로부터 특정지역의 지반운동의 특성을 이해할 수 있는 스펙트럼 가속도, 최대 가속도, 및 최대속도 값에 따른 감쇠식을 구하였다. 이것을 한반도와 같은 판 내부 환경인 ENA 값과 비교하였으며 기존의 연구와도 비교하였다.심으로부터 지오이드까지의 거리, 지오이드로부터 지표까지의 거리를 정의해주었으며, 각 격자점의 수직구조를 정의하기 위해 깊이에 따른 각 매질의 밀도, P파의 속도, S파의 속도, P파에 대한 Q값, S파에 대한 Q값을 정의 해주었다. S파의 속도를 구하기 위해서 지구 내부 물질을 포아송 매질이라는 가정 하에, 관계식을 $Vp{\;}={\;}SQRT(3){\;}{\times}{\;}Vs$ 이용하였다. 획득한 모델치들을 이용해 동해와 동해 인근 지역에 대한 초기모델을 구축하였다. 약 1 × 10/sup 6/ e/sup -//sec·n㎡ 의 전자선량에 해당되며 이를 기준으로 각각의 illumination angle에 대한 임계전자선량을 평가할 수 있었다. 실질적으로 Cibbsite와 같은 무기수화물의 직접가열실험 시 전자빔 조사에 의해 야기되는 상전이 영향을 배제하고 실험을 수행하려면 illumination angle 0.2mrad (Dose rate : 8000 e/sup -//sec·n㎡)이하로 관찰하고 기록되어야 함을 본 자료로부터 알 수 있었다.운동횟수에 의한 영향으로써 운동시간을 1일 6시간으로 설정하여, 운동횟수를 결정하기 위하여 오전, 오후에 각 3시간씩 운동시키는 방법과 오전부터 6시간동안 운동시키는 두 방법을 이용하여 품질을 비교하였다. 각 조건에 따라 운동시킨 참돔의 수분함량을 나타낸 것으로, 2회(오전 3시간, 오후 3시간)에 나누어서 운동시키기 위한 육의 수분함량은 73.37±2.02%를 나타냈으며, 1회(6시간 운동)운동시키기 위한 육은 71.74±1.66%을 나타내었다. 각각의 운동조건에서 양식된 참돔은 사육초기에는 큰 변화가 없었으나, 사육 5일 이후에는 수분함량이 증가하여 15일에는 76.40±0.14, 75.62±0.98%의 수분함량을 2회와 1회 운동시킨 참돔의 육에서 각각 나타났다. 운동횟수에 따른 지

  • PDF

Response Reduction of a SDOF Structure based on Friction Force Ratio of MR Controller (MR제어기의 마찰력비에 따른 단자유도 구조물의 응답감소)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.435-443
    • /
    • 2010
  • This study presents key parameters for the structure installed with MR controller in reducing its responses. MR controller is regarded as Bingham model of which control forces are frictional and viscous ones. The parameters are identified as friction force ratios, $R_f$ and $R_h$ which are, respectively, ratio of MR controller friction force to static restoring force for free vibration and ratio of the friction force to amplitude of harmonic force. Structure-MR controller system shows nonlinear response behavior due to friction force. Energy balance strategy is adopted to transform the behavior to linear one with equivalent damping ratio. Finally, proposed equivalent linear process is compared to the nonlinear one, which turns out to give acceptably good results.