• Title/Summary/Keyword: 수직 진동

Search Result 542, Processing Time 0.03 seconds

Vibration Reduction of Pump And Pipe System (배관계와 조합된 대형 수직펌프의 유체진동 저감)

  • 배춘희;김성휘;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.263-266
    • /
    • 2004
  • In this paper, Firstly, it is shown that the high vibration source of piping and pump system is the Resonanse of pump and piping system. Secondly, in order to decrese the high vibration of pump and piping system, some practical Friction damper with high damping have been developed and its effectiveness is investigated as installing it at piping system practically.

  • PDF

Dynamic Responses of Korean-Seated Subjects to Vertical Vibration (한국인의 앉은 자세에 대한 수직 진동의 응답 특성)

  • 정완섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.33-44
    • /
    • 2003
  • This paper introduces attempts to obtain the'representative'characteristics of the apparent mass and mechanical impedance of seated Korean subjects under vertical vibration. Individual responses of the apparent mass and driving-point mechanical impedance obtained from forty-one Korean subjects are illustrated. Four kinds of vibration levels and three different sitting postures are selected to collect the responses of each subject. Those individual responses are used to estimate the 'mean' mechanical impedance, which may be expected to be a representative model to Korean subjects. Several interesting features of the estimated mechanical impedance are suggested and compared to those of ISO 5982.

  • PDF

Vibration Reduction By Dynamic Absorber of Vertical Pump System (동흡진기를 통한 수직펌프의 진동 저감)

  • 배춘희;조철환;양경현;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.628-632
    • /
    • 2001
  • In this paper, Firstly, it is shown that the bending mode vibration source of vertical pump system is comparatively large because resonance. Secondly in order to the bending mode vibration of vertical pump some practical dynamic absorber have been developed and its effectiveness is investigated as installing it at the vertical pump system practically.

  • PDF

A Study on the Attenuation of Flip-over Vibration in the Flat Blade Windshield Wiper (플랫 블레이드 윈드실드 와이퍼의 역전 진동 저감에 관한 연구)

  • Lee, Hyeong-Ill
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.974-984
    • /
    • 2012
  • This research introduces a new method to attenuate flip-over vibration generation in the flat blade windshield wiper by adjusting the contact pressure between the windshield glass and the blade. The knocking force in the flip-over action of the blade is decreased by inducing gradual tilting-over along the rubber strip of the blade. This gradual tilting-over is induced by introducing a non-uniform contact pressure distribution between the blade and windshield glass. The contact pressure distribution is adjusted by controlling the unloaded profile of the body spring in the blade using a procedure proposed in a previous study. Two blades, one blade designed to generate a uniform pressure distribution and the other designed to generate non-uniform pressure distribution, are developed using the procedure. Contact pressure distributions of the developed blades are measured using a special device and compared with the intended distributions confirming the similarities between the two groups. Vertical and lateral vibrations of the two blades are measured under realistic operating condition simulated by a wiper test rig. The vertical vibrations of the blade with non-uniform contact pressure are substantially smaller than corresponding vibrations of the blade with uniform contact pressure over the entire rubber strip.

Development of ETMD(Electromagnetic Tuned Mass Damper) for Smart Control of Structure (구조물 스마트제어를 위한 ETMD(Electromagnetic Tuned Mass Damper)개발)

  • Jeon, Seung-Gon;Heo, Gwang-Hee;Lee, Chin-Ok;Lee, Jae-Hoon;Kim, Dae-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2022
  • The TMD has a simple structure than other vibration control devices and shows excellent control performance for the simple harmonic vibration generated in the structure. However, the vibration control range is narrower than other control devices, making it vulnerable to vibration cycles caused by unexpected external loads. The ETMD developed in this study consisted of Mass with electromagnets. Therefore when supplying a current, the magnetic field is formed to increase the friction force with the friction plate, thereby instantaneously controlling the behavior of the Mass. The experiment was conducted to compare the control performance of the control device by installing the ETMD developed for control performance evaluation in the center of the model simple beam bridge to forced excitation at 3.02 Hz where the maximum bending displacement occurs. As a result of the experiment, ETMD exhibited excellent control performance with a maximum bending displacement attenuation rate of 57.51%.

Vertical Vibration of Rigid Circular Footings on Sand (사질토(砂質土) 위에 놓인 강성(剛性) 원형기초(圓形基礎)의 수직진동(垂直振動))

  • Kim, Soo Il;Min, Tuk Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.127-136
    • /
    • 1985
  • A simplified single degree of freedom analog with mass-spring-dashpot is proposed in this study. The simplified analog can describe the dynamic behavior of a rigid circular footings whose contact pressures are parabolic. The analog proposed in this study shows remarkable agreement when compared with the elastic half-space theory the analog is also compared with vertical vibration test results of model concrete footings. For the vibration experiments, 11 circular footings with different mass ratio are constructed. The elastic half-space is represented by compacted sand layer. A constant force excitation vibrator is used for the dynamic loading. The frequency range for vibration tests is 30 to 100 Hz. From the dynamic experiments, it is found that the measured resonant frequencies agree very well with the analog results, however, the ratio of theoretical and measured resonant amplitudes vary between 0.5 and 1.7. It is also found that, when the dynamic force is increased, the resonant frequency is decreased slightly and the resonant amplitude is increased slightly.

  • PDF

Shaking Table Tests of a 1/4-Scaled Steel Frame with Base Isolators (1/4축소 철골구조물을 이용한 건물 기초분리장치의 진동대실험)

  • 송영훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.39-48
    • /
    • 1997
  • New form of base isolators made of steel spring coated with both natural and artficial rubber were manufactured and tested for material properties. Shaking table experiments were performed using a model structure attached with the bearings. The model structure used in the test is a 1/4 scaled steel structure, and earthquake records were used to check the lateral and vertical stability and effectiveness of the isolators. According to the results all three types of isolators turned out to be effective in reducing the acceleration induced by the earthquake vibration.

  • PDF

A Study on Working Vibration of Structure Horizental Mobility (구조물 바닥의 수직 모빌리티에 따른 건물보행 진동 영향성 평가)

  • Ryu, Kuk-Hyun;Lee, Hong-Ki;Park, Hae-Dong;Kim, Kang-Bu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1346-1349
    • /
    • 2007
  • 신축 구조물의 설계 단계에서 동적 강도 기준 및 진동 설계 기준을 설정하고 사람의 거동에 따른 기준층 구조의 동적 사용성 및 건물의 용도별 진동 영향성 평가를 동적 시뮬레이션 기법을 토대로 정량적인 방법을 통하여 수행하고 그 결과를 바탕으로 건물 사용성 및 용도에 따른 구조물의 안정성, 근무 요원들의 근무 환경 및 건물 운용의 관점에서 진동 영향성 평가를 수행함과 동시에 필요한 경우 최적의 동적 대책을 수립한다. 또한 건물 내부의 운용설비가 구조물에 미치는 영향을 평가하여 최적의 방진 대책을 제시하여 건물 완료 후 발생할 수 있는 진동 문제를 최소화 하고자 한다.

  • PDF

Analysis of Vertical Vibration of a Passenger Car due to Road Excitation (노면가진을 받는 승용차의 진동해석)

  • 최영휴;김원석;민현기;이장무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.143-147
    • /
    • 1990
  • 자동차는 주행시에 노면가진으로 인하여 진동을 받게 되는 데 이러한 진동 은 운전자의 승차감을 저하시킬 뿐만 아니라 화물과 차량 부품을 파손시키 는 원인이 되기도 한다. 노면가진력은 주로 현가장치를 통하여 차량에 전달 되어 차량의 진동을 유발하게 되므로 승차감을 향상시키려면 노면가진을 효 과적으로 차단할 수 있도록 현가장치를 설계하여야 한다. 이를 위하여 본 논 문에서는 차량을 현가장치의 형식에 따라 3가지 종류로 구분한 다음 각각을 12자유도로 모델링하여 노면이 불규칙(random)한 도로를 주행할 때의 승용 차의 진동을 해석하고, 현가스프링의 강성과 쇼크 압소바의 감쇠 값이 자체 수직 가속도 유효치(rms value)와 현가장치 유효행정(rms stroke length)에 미치는 영향을 분석하였다. 차량의 운동방정식은 현가장치의 비선형 특성을 고려하였기 때문에 미소 각 운동의 가정에도 불구하고 비선형 방정식이 된 다. 운동 방정식의 해는 4차 Runge-Kutta 적분법을 사용하여 수치해석으로 구하였다.

  • PDF

A Study on the Diagnostic System for Reactor Coolant Pump (원자로 냉작재 펌프 진단 시스템에 관한 연구)

  • 배용채
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.723-732
    • /
    • 1998
  • 원자력 발전소에서 운전되고 있는 원자로 냉각재 펌프는 대형 수직 펌프로서 증기 발생기로부터 원자로에 냉각재를 순환시키는 중요한 역할을 담당하고 있다. 원자로 냉각재 펌프는 운전 조건 및 각종 결함에 따라 진동, 열적 변형, 마모 등의 비정상 상태에서 운전될 수 있으며, 이로 인한 발전소 신뢰성 저하의 원인이 된다. 따라서 이 펌프의 감시 및 진단에 대한 연구가 계속되어 왔으며 각종 시스템이 설치 운용되고 있다. 그러나 미국내의 거의 모든 냉각재 펌프 감시 시스템은 펌프의 고진동 여부만을 나타내며 진동의 원인을 진단하기 어렵다. 본 연구에서는 최근까지 주로 발생되었던 미국내 원자로 냉각재 펌프의 문제점을 분석하고 이들의 원인별 진동 특성을 지식베이스화 하였으며, 진단시스템 개발을 위한 알고리즘을 제안하였다.

  • PDF