• Title/Summary/Keyword: 수직 단면

Search Result 446, Processing Time 0.031 seconds

Cosmogenic Nuclides Dating of the Earth Surface: Focusing on Korean Cases (우주선유발 동위원소를 이용한 지표면의 연대측정: 국내 사례를 중심으로)

  • Seong, Yeong Bae;Yu, Byung Yong
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.261-272
    • /
    • 2014
  • Over the last three decades, advances in AMS (Accelerator Mass Spectrometry) and Noble Gas Mass Spectrometer make various application of terrestrial cosmogenic nuclides (CNs) to wide range of earth surface sciences possible. Dating techniques can be divided into three sub-approaches: simple surface exposure dating, depth-profile dating, and burial dating, depending on the condition of targeted surfaces. In terms of Korean landscape view, CNs dating can be applied to fluvial and marine terrace, alluvial fan, tectonic landform (fault scarp and faulted surfaces), debris landforms such as rock fall, talus, block field and stream, lacustrine and marine wave-cut platform, cave deposits, Pliocene basin fill and archaeological sites. In addition, in terms of lithology, the previous limit to quartz-rich rocks such as granite and gneiss can be expanded to volcanic and carbonate rocks with the help of recent advances in CNs analysis in those rocks.

A Study on the Optimum Design of Piled-raft Foundation Considering Pile Head Condition (말뚝두부구속조건을 고려한 말뚝지지 전면기초의 최적단면 설계)

  • Cho, Jae-Yeon;Lee, Sung-June;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.31-40
    • /
    • 2010
  • This study describes the three-dimensional behavior of pile foundations based on a numerical study. A series of numerical analyses were performed for connectivity conditions between piles and cap under vertical and lateral loadings. It is shown that a fixed connection between pile and cap is able to transfer significant bending moment through the connection and increases the pile lateral stiffness and the bending moment. Based on the results obtained, it was found that the cross sectional shear force in the raft with fixed head condition was larger than that of pinned head condition. Thus, the reinforcement of pile head and thickness of the raft also increases in fixed pile head condition. From the results, it is found that the overall behavior and cross sectional forces of pile foundations is affected significantly by the pile head conditions. Furthermore, the design of pile foundations with pinned head condition was judged to be less costly and very useful for preliminary design stages.

Cosmogenic 10Be Depth Profile Dating of Strath Terrace Abandonment using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 하안단구 10Be 수직단면 연대측정)

  • Kim, Dong-Eun;Seong, Yeong Bae;Kim, Jong-Geun
    • Journal of The Geomorphological Association of Korea
    • /
    • v.26 no.4
    • /
    • pp.21-31
    • /
    • 2019
  • Timing of terrace formation is a key information for understanding the evolution of fluvial systems. In particular, dating strath terrace (i.e. timing of terrace abandonment) is more difficult than depositional terrace that is conventionally constrained by radiocarbon, OSL and other dating methods targeting samples within terrace deposit. Surface exposure dating utilizing cosmogenic 10Be provides more reliability because it can be applied directly to the surface of a fluvial terrace. Thus, this method has been increasingly used for alluvial deposits. As well as other geomorphic surfaces over the last decades. Some inherent conditions, however, such as post-depositional 10Be concentration (i.e. inheritance), surface erosion rate, and density change challenge the application of cosmogenic 10Be to depositional terrace surface against simple bedrock surface. Here we present the first application of 10Be depth profile dating to a thin-gravel covered strath terrace in Korea. Monte Carlo simulation (MCS) helped us in better constraining the timing of abandonment of the strath terrace, since which its surface stochastically denuded with time, causing unexpected change of 10Be production with depth. The age of the strath terrace estimated by MCS was 109 ka, ~4% older than the one (104 ka) calculated by simple depth profile dating, which yielded the best-fit surface erosion rate of 2.1 mm/ka. Our study demonstrates that the application of 10Be depth profile dating of strath terrace using MCS is more robust and reliable because it considers post-depositional change of initial conditions such as erosion rate.

Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges (이중합성 교량의 복합스터드 전단연결부의 정적강도 평가)

  • Kim, Hyun Ho;Shim, Chang Su;Yun, Kwang Jung;Lee, Pil Goo
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.549-559
    • /
    • 2005
  • A railway bridge with a double composite section is proposed to enhance the structural performance of existing two-girder bridges because the governing design parameter of railway bridges is the flexural stiffness. The concrete deck in negative moment regions is neglected in the design of continuous composite bridges assuming the concrete slab has no resistance to tension. Therefore, the flexural stiffness of the composite section in the negative moment region is reduced resulting in the increase of the depth of the steel section. In order to resolve this disadvantage, several methods are suggested and the double composite section is one of the excellent solutions for extending the span length and increasing the flexural stiffness. In this study, push-out tests on lying studs and mixed stud shear connection with lying and vertical studs were performed to investigate the behavior of the shear connection in the double composite section. Static strength of the shear connection was evaluated through the test results and numerical analyses.

Measurement and Proposed Design Specification of Temperature Distribution in the Concrete Pylon (콘크리트 주탑의 온도분포 계측 및 설계규정 제안)

  • Hwang, Eui-Seung;Shim, Jae-Soo;Kim, Do-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • This paper deals with monitoring and analysis of temperature measurement data in concrete pylon of long span cable bridges. During the construction of Geoga Bridge in Busan-Geoje Fixed Link Project, temperature sensors were installed in several sections of hollow box type concrete pylon and temperatures along the depth of the four sides of the section have been recorded along with ambient temperature. Effects of temperature distribution on the pylon are analysed using actual measured data and results are compared with the design guideline. It was found that the temperature load model for concrete girder can be applied to box type concrete pylon. Structural analysis of the pylon due to variation of temperature distribution during the construction is performed using 3D modelling and FE program and the maximum displacements of east-west and north-south side were calculated as 0.056m and 0.121m, respectively.

Stress Analysis of PS Anchorage Zone Using Ultra High Performance Concrete (UHPC를 적용한 PS 정착부의 응력해석)

  • Kim, Jee Sang;Choi, Yoon Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1349-1360
    • /
    • 2013
  • The post-tensioned anchorage zones of normal concrete have larger cross sections because of congested reinforcements to resist high bearing and bursting stresses. The high compressive and tensile strength of newly developed UHPC (Ultra High Performance Concrete) may reduce the cross sectional dimensions and simplify the reinforcement details, if used for post-tensioned members. The Finite Element Analysis was performed to evaluate the mechanical behavior of post-tensioned anchorage zones using UHPC without anchorage plates and confining reinforcements. The results show that the maximum bursting stresses are less than the values given in current design code without failure due to vertical cracks. The location of maximum bursting stresses were at 0.2 times of width of the models. The bursting force from FEA is less than that is obtained using simplified formular in Korean Bridge Design Code.

Evaluation of the Seismic Stability of Fill Dam by Shaking Table Tests (진동대 시험을 통한 Fill Dam의 내진 안정성 평가)

  • Yoon, Won-Sub;Chae, Young-Su;Park, Myeon-Gu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.81-92
    • /
    • 2011
  • In order to understand evaluation of the seismic stability of a fill dam, we made chambers of 1:100, 1:70, and 1:50 (the ratio of the miniature), considering the law of similarity based on drawings of three representative cross sections. And we measured an increase in acceleration, excess pore water pressure, and vertical/horizontal displacement after applying Hachinohe wave (long period), Ofunato wave (short period), and artificial wave, complying with the domestic standards, in order to evaluate the stability and interaction between the ground, the structure, and fluids based on the measurements. As a result, we could observe that displacement of the target cross section was relatively small compared to the allowed level of 30 cm, ensuring proper stability for an earthquake. Regarding the acceleration measurements, the increase rate was 20% for Hachinohe wave and Ofunato wave but 30% for the artificial wave. With respect to the excess pore water pressure, it was lower than 1 (which is the permissible ratio for liquefaction) ensuring proper stability as well.

Evaluation of Effective Section Area of Shear Steel in Reinforced Concrete Circular Columns (철근콘크리트 원형기둥의 전단철근 유효단면적 평가)

  • 김장훈
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.81-88
    • /
    • 1999
  • In order to properly evaluate the shear strength of reinforced concrete circular columns due to the transverse shear reinforcement, the average of fractions of forces generated along the circular transverse hoops across the shear failure plane in the loading direction is calculated. For this, the center-to-center diameter of circular transverse hoops. spacing and the crack angle measured to the column longitudinal axis are considered. Using these variables, an equation representing the effective section area of circular transverse shear steel is proposed. The study result shows that the constant parameter. used for the calculation of the effective section area of circular hoops over the last 10 years, should not universally be applied any more. The use of the constant parameter may not seriously do harm to the evaluation of shear strength for circular columns with non-seismically designed transverse hoop reinforcement, since it gives slightly conservative results. However. for well-confined circular columns with close spacing or circular steel jacketing. it gives about 20% overestimation of the shear capacity contributed by the transverse hoop steel.

The Impact of Armor Block Failure on Wave Pressure Acting on a Vertical Wall at the Front of a Caisson (피복 케이슨의 소파블록 이탈이 직립벽에 작용하는 파압에 미치는 영향)

  • Taegun Park;Yeon-Myeong Jung;Jeongheum Lee;Jaeheon Jeong;Dong-Soo Hur
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.303-309
    • /
    • 2024
  • This study examines the effects of wave pressure on a vertical wall due to armor block failure at the front of a caisson, using a 2-D hydraulic model to simulate three types of armor block cross-sections. Additionally, the hydraulic characteristics of two cross-sections that replicated the armor blocks' failure, based on complete cross-sections, were compared. Moreover, quantitative analysis indicated that in the cross-section where the displacement of the armor block was recreated, wave run-up( ) increased by an average of 73%, the sum of dimensionless wave pressures increased by 28%, and converted wave force rose by 33%. These findings underscore the need for countermeasures in the event of armor block failure.

Stiffness Reduction Effect of Vertically Divided Reinforced Concrete Shear Walls Under Cyclic Loading (반복하중을 받는 수직분할된 철근콘크리트 전단벽의 강성저감효과)

  • Hwangbo, Dong-Sun;Son, Dong-Hee;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.103-110
    • /
    • 2022
  • The purpose of this study is to experimentally evaluate the stiffness and strength reduction according to the reinforcing bar details of the vertically divided reinforced concrete shear walls. To confirm the effect of reducing strength and stiffness according to vertical division, four real-scale specimens were fabricated and repeated lateral loading tests were performed. As a result of the experiment, it was confirmed that the strength and stiffness were decreased according to the vertical division. In particular, as the stiffness reduction rate is greater than the strength reduction rate, it is expected that safety against extreme strength can be secured when the load is redistributed according to vertical division. As a result of checking the crack pattern, a diagonal crack occurred in the wall subjected to compression control among the divided walls. It was confirmed that two neutral axes occurred after division, and the reversed strain distribution appeared in the upper part, showing the double curvature pattern. In future studies, it is necessary to evaluate the stiffness reduction rate considering the effective height of the wall, to evaluate additional variables such as wall aspect ratio, and to conduct analytical studies on various walls using finite element analysis.