• Title/Summary/Keyword: 수소충전

Search Result 255, Processing Time 0.031 seconds

Advanced Technologies for the Commercialization of Hydrogen Fuel Cell Electric Vehicle (수소연료전지자동차의 최신기술)

  • Cho, Mann;Koo, Young-Duk
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.132-145
    • /
    • 2014
  • There is a general agreement that performance of hydrogen fuel cell vehicle(FCV) with respect to cold start, packaging, acceleration, refueling time and range has progressed to the point where vehicles that could be brought to market in 2015_2020 will satisfy customer expectations. However cost, durability and the lack of refueling infrastructure remain significant barriers. Cost have been dramatically reduced and durability has been enhanced over the past decade, yet are still about twice what appears to be needed sustainable market success. Advanced Technologies for the commercialization of hydrogen FCV were reviewed.

A Study on Site to Build Hydrogen Multi Energy Filling Station in Domestic LPG Station (국내 LPG 충전소 내 수소 융·복합충전소 구축 가능 부지 연구)

  • PARK, JIWON;HUH, YUNSIL;KANG, SEUNGKYU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.642-648
    • /
    • 2017
  • The use of fossil is causing enviromental all over the world. So hydrogen energy is attracting attention as one of the alternative. The government announced that 30% of the air pollution is because of the Internal Combustion Engine Vehicle. In addition, they plans to reduce Internal Combustion Engine Vehicles by 2030 and increase (electric vehicles, EV) or (fuel cell vehicle, FCV). The FCV is evaluated as a next-generation green car because it has a long driving distance and short charging time. However, the hydrogen industry is not able to expand due to the lack of refueling infrastrucutre. This paper predicts the site of hydrogen refueling stations for the expansion of the hydrogen industry and proposes a method to supply hydrogen multi energy filling stations.

Study on Cooling of Hydrogen Gas for the Pre-Cooler in the Hydrogen Refueling Station (수소충전소용 프리쿨러를 위한 수소가스 냉각에 관한 연구)

  • LEE, KYUNG-HAN;KOO, KYUNG-MO;RYU, CHEOL-HWI;HWANG, GAB-JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.237-242
    • /
    • 2019
  • In the hydrogen refueling station (HRS), it is need the pre-cooling system (PCS) to limit the inside temperature ($85^{\circ}C$) of the onboard thank (700 bar) and to charge the hydrogen at short time (within 3 minutes) to fuel cell electric vehicle (FCEV). From those safety reasons, the temperature of hydrogen gas must be controled $-33^{\circ}C$ to $-40^{\circ}C$ in PCS. The cooling test of the gaseous ($N_2$, He, $H_2$) was carried out using heat exchanger (pre-cooler) by indirect cooling and direct cooling method. It was confirmed that the temperature of hydrogen gas had below $-40^{\circ}C$ at below $-75^{\circ}C$ of chiller temperature in direct cooling.

A Numerical Analysis Study of Hydrogen Valve to Flow Characteristics by Fluid Temperature Variation for Mobile Charging Equipment (이동식 수소 충전 장비용 수소 밸브의 유체 온도 변화에 따른 유동 특성의 수치해석적 연구)

  • JUNYEONG KWON;SEUNGJUN OH;JEONGJU CHOI;YONGKI KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.769-775
    • /
    • 2022
  • Global efforts to reduce carbon emissions have focused attention on the development of hydrogen energy and the development of various hydrogen mobility requires mobile hydrogen charging stations. In this study, the flow characteristics of the flow control hydrogen valve for mobile hydrogen charging equipment were studied according to the temperature change of hydrogen gas. The inlet pressure was 100 MPa, the outlet pressure to 70 MPa, and temperature condition was set -40℃ to 85℃. As a result, the difference in the valve flow coefficient, which determines the capacity of the valve, showed a difference within 5% depending on the temperature.

수소 충전설비의 안전성 평가

  • Kim, Jeong-Geun;Lee, Gwang-Won;Lee, Taek-Hong;Kim, Tae-Hun;Lee, Man-Su;Cheon, Yeong-Gi
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2005.10a
    • /
    • pp.428-434
    • /
    • 2005
  • PDF

Effect of Biofilter Made of Composted Pine Tree Bark and Perils on Reducing Odor from Pig House (부숙수피-펄라이트 혼합충전재의 돈사악취 제거 효과)

  • Lee, Seung-Joo;Chang, Dong-Il;Chang, Hong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.118-123
    • /
    • 2006
  • To remove effectively order component ($NH_3\;and\;H_2S$) from pig house, biofilter was made of composted pine tree bark and polite and odor removal efficiency was evaluated in the lab and pilot scales. The columns were designed with ${\Phi}120mm{\times}450mm$ (H) and ${\Phi}850mm{\times}900mm$ (H) in the size in the lab and pilot scale testes, respectively. Single material of composted pine tree bark and polite and the mixture of two materials with 7:3 ratios (vol/vol) were packed in the column, and, herein air flow was controlled upward direction from column bottom. To enhance the efficiency of biofilter, ammonia (Rhodococcus equi A3) and hydrogen sulfide oxidizing bacteria (Alcaligenes sp. S5-5.2) were inoculated in packing materials before the test Removal effect of ammonia and hydrogen sulfide gases were higher in the mixture$[88.7{\sim}98.2%,\;89.5{\sim}97.9%]$ than that in single packing material (composted pine tree haft$[89.4{\sim}98.7%,\;78.7{\sim}85.6%]$ and petite$[65.3{\sim}73.2%,\;88.7{\sim}98.2%]$ by the lab scale biofilter. In the modeled pig house, about 96 and 91% of ammonia and hydrogen sulfide gases were removed by the pilot scale of biofilter, respectively. Conclusively, composted pine tree bark and polite could be a good candidate of biofilter packing materials to remove the odor components.

Development of Lightweight DMFC System for Charging Secondary Battery in Military Operational Environment (군 운용환경에서 이차전지 충전을 위한 경량화 DMFC 시스템 개발)

  • LEE, SUWON;GWAK, GEONHUI;RO, JUNGHO;CHO, YOUNGRAE;KIM, DOYOUN;JU, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.481-491
    • /
    • 2017
  • In this study, we developed 300 W lightweight DMFC system for charging secondary battery in small unit military operation. In order to reduce the volumetric shape and weight of the system considering the environment of the individual soldier's, the arranging of system components has been optimized. A metal bipolar plates made of STS-470FC have been implemented to the DMFC stack to meet the weight demand of the system. As a result of the performance test of the stack, the target value was satisfied by outputting 561 W exceeding 24% of the stack output 450 W required to output 300 W required for the entire system. Moreover, 2,655 hours exceeding 1,000 hours also has been satisfied. To ensure good robustness of the metallic bipolar plate based DMFC stack, finite element method based simulations are conducted using a commercial ANSYS Fluent software.

A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station (수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구)

  • Hwayoung, Lee;Hyeonwoo, Jang;Minkyung, Lee;Jeonghwan, Kim;Jaehun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.30-36
    • /
    • 2022
  • In commercial transactions of energy sources using hydrogen charging stations, high-accuracy flow meters are needed to prevent accidents such as overcharging due to inaccurate measurements and to ensure transparency in hydrogen commercial transactions through accurate measurements. This research developed a Corioli-type flowmeter prototype and conducted a risk assessment to prevent accidents during a process change comparison experiment for existing charging stations to verify the measurement performance. A process change section was defined for the installation of measurement facilities for empirical experiments and HAZOP was conducted. In addition, JSA was also conducted to secure the safety of experimenters, such as preventing valve mis-opening during empirical experiments. Measures were established to improve the risk factors derived through HAZOP, and work procedures were established to minimize human errors and ensure the safety of workers through JSA. The design change and system manufacturing for the installation of the metering system were completed by reflecting the risk assessment results, and safety could be confirmed through the performance comparison test of the developed meter prototype. The developed prototype flow meter showed a total of 30 flow measurements under the operating conditions of 70 MPa, and the average error was -1.58% to 3.96%. Such a metering error was analyzed to have the same performance as a flow meter installed and operated for commercial use.