• Title/Summary/Keyword: 소화

Search Result 4,228, Processing Time 0.027 seconds

가스계소화설비의 약제 방출량에 대한 이론적 고찰 및 방출시험 (II)

  • Park, Sin-Yeong;Kim, Wi-Gyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.71-72
    • /
    • 2013
  • 가스계 소화설비는 소방관계법에 따른 인증 프로그램에 의해 설계를 수행한다. 하지만, 현장에 설치되는 가스계 소화설비는 공급배관의 규모 및 형상에 차이가 있어 인증 프로그램의 적절성을 보장 할 수가 없다. 따라서 모의시험을 통해 선택밸브 위치에 따른 차이점을 검증하여 모의시험의 개선방향을 제시하고 직접 방출시험의 소개와 가스계 소화설비의 판정방법 개선 필요성을 제시하고자 한다.

  • PDF

Hybridization in Aconitum subgenus Aconitum at Mt. Sobaek in Korea (소백산 초오속 초오아속(미나리아재비과) 식물의 잡종형성)

  • Lim, Chae Eun;Park, Chong-Wook
    • Korean Journal of Plant Taxonomy
    • /
    • v.31 no.4
    • /
    • pp.343-358
    • /
    • 2001
  • We have examined the pedicel pubescence and other major morphological characters of 11 putative hybrid populations of Aconitum subgn. Aconitum at Mt. Sobaek to understand their origin. These populations show very complicated patterns of variation in pedicel pubescence ; they contain individuals having pedicels (1) completely glabrous, (2) with few micropapillate curved hairs near the receptacle, (3) moderately pubescent with micropapillate curved hairs from middle to upper portion, (4) sparsely pubescent with a mixture of micropapillate curved hairs and smooth-surfaced spreading glandular hairs near the receptacle, and (5) moderately pubescent with both types of hairs but from middle to upper portion. All five types of individuals co-occur in most populations with varying proportions. These results, in conjunction with evidence from the analysis of other major morphological characters, suggest that the populations at Mt. Sobaek were derived from the multiple hybridization events involving A. kusnezoffii, A. japonicum subsup. napiforme, and A. jaluense subsp. jaluense. In addition, the absence of "typical" forms of these putative parental taxa in Mt. Sobaek area suggests that repeated introgression has probably occurred in these populations.

  • PDF

A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding (전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구)

  • Lee, Se-Myeoung;Moon, Sung-Woong;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.15-23
    • /
    • 2012
  • Indirect Test Method is often used instead of direct test method in test method for extinguishing performance of $CO_2$ extinguishing facility because of high cost, environment problems and difficulties of procedure. But in the danger facilities for a unit of nation, such as a petrochemical plant, a nuclear power plant, or etc. is better to verify the performance of the extinguishment through direct discharge test. In $CO_2$ extinguishing system for total flooding system installed in dangerous facilities in Korea, each protected area in surface fire and deep-seated fire had selected and verified of extinguishing performance of $CO_2$ extinguishing facilities. To get recognized as extinguishing performance, discharged $CO_2$ concentration to protected area should be equivalence with design concentration standards (NFSC and NFPA). The Design Concentration means that $CO_2$ extinguishing agent is considerate of concentration for percentage of allowance (20 %) from extinguishing concentration which available to control of flame. As test result, surface fire and deep seated fire in protected area is obtained $CO_2$ design concentration and maintained design concentration more than 20 minutes as deep-seated fire. Through this study, we introduced direct discharging test method and decision method. And furthermore, especially in the dangerous facilities as a unit of Nation, we suggested necessity about reliability of extinguishing facilities to use direct test method.

Effect of Heat Treatment on the In Vitro Protein Digestibility and Trypsin Indigestible Substrate (TIS) Contents in Some Seafoods (수산단백질(水産蛋白質) 소화화(消化華)에 미치는 가열처리(加熱處理)의 영향(影響))

  • Ryu, Hong-Soo;Lee, Kang-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.14 no.1
    • /
    • pp.1-12
    • /
    • 1985
  • In an attempt todetermine the optimum heat treatment, the changes in TIS content and in vitro protein digestibility of squid, shrimp, oysterand pollock under various heating conditions were studied. The effect of drying method and cold storage on the in vitro digestibility and TIS content were also studied. Optimal boiling conditions were 1 min, for squid, 0.5min. for oyster(eviscerated), 1 min. for whole oyster, and 5 min. for pollock. Steaming times that yieled products with the highest in vitro digestibility value were: 1 min. at $100^{\circ}C$ for squid, 1 min, at $88^{\circ}C$ for oyster and $1{\sim}2.5min$. at $100^{\circ}C$ for pollock. All of freeze dried samples showed the highest in vitro digestibility value and sundried one were comparble to freeze dried samples except high fat level or noneviscerated samples. Fat content was the nain inhivbitory factor of the seafood enzymic digestion during processing and storage. The multi-enzyme assay, used to predict the quality change of dried seafoods stored in a cold room for long periods of raw seafoods treated with various heating methods, offers many advantages over the convetional methods of determining protein quality.

  • PDF

Response Characteristics of Perceived Stress Response Inventory in Patients with Upper Gastrointestinal Disorder (상부 위장관 장애 환자에서의 스트레스반응 지각척도의 반응특성)

  • Suh, Yong-Woo;Cho, In-Hee;Shin, Kwang-Chel;Chung, Yong-Kyoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.2
    • /
    • pp.172-180
    • /
    • 2000
  • Objectives : We investigated the characteristics of perceived stress response and relationship between some variables of gastrointestinal symptoms(esp., dyspepsia) and subscales of perceived stress response inventory(PSRI) in patients with upper gastointestinal disorder when they perceived stress. Methods : 84 patients with upper gastrointestinal disorder(gastritis, gastric ulcer, duodenal ulcer etc.) and 94 normal controls completed the PSRI developed by Korean psychiatrists. The patient group performed the questionnaire including some variables of gastrointestinal symptoms. Results : Internal consistency was statistically significant in all subscales of PSRI. The patient group was significantly higher at total score of PSRI, general somatic symptom subscale score, specific somatic symptom score than control group. As the result of stepwise regression analysis for relationship between some variables of gastrointestinal symptoms ans subscales of PSRI, specific somatic symptom subsclae closely related with illness duration, past illness history and severity of symptom, and the lowered cognitive function & general negative thinking subscale related with the existence of emotional distress. Conclusion : Patients with upper gastrointestinal disorder showed stronger perceived stress response than control group and they experiences somatic symptoms related to autonomic nervous system and/or gastrointestinal symtoms rather than emotional, cognitive, behavioral symtoms when they perceived stress. They also responded to stress as they expeirenced specific somatic symtom when they had long illness duration, past illness history, and high severity of symptom and the existence of emotional distress could develop lowered congnitive function and general negative thinking.

  • PDF

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.

Effect of Alkaline Pretreatment on Sludge Aerobic Digestion and Fertilizer Value (알칼리 전처리에 의한 슬러지 호기성 소화 및 액비 특성 변화)

  • Hwang, Eung-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.90-96
    • /
    • 2008
  • In order to meet the stringent requirement of sludge disposal and to find ecological alternative, aerobic digestion coupled with alkaline pretreatment was studied. The treated sludge was tested for the potential of liquid fertilizer. In the aerobic digestion, it was obvious that the performance of digester B(fed with the sludge pretreated by NaOH) was better than that of digester A(fed with raw sludge) in terms of COD and SS removal. SS and VSS removal rates in digester B were 66% and 69%, respectively. At 5 days, TSS removal rate reached 47% in the digester B, which was 71% of final TSS removal rate. It revealed that the pretreatment process can shorten the retention time of aerobic digestion. 94.1% of TCOD in the raw sludge was reduced by alkaline pretreatment and aerobic digestion. Final SCOD was in the range of 220$\sim$230 mg/L implying the sludge was stabilized. Nitrification and pH drop were observed in the aerobic digestion. Final nitrate concentrations in digester A and B were 445.4 and 223.1 mg/L and final pH in digester B was 3.0. Biological assays reported that leaf size of cucumber seedling increased with nitrate concentration and sludge to soil ratio. The sludge treated by alkaline and aerobic digestion promoted the growth of seedling leaf and stem remarkably compared to raw sludge. In contrast, the aerobically digested sludge without pretreatment improved leaf growth and inhibited stem growth.

Evaluation test of applicability of Compressed Air Foam fire extinguishing system for train fire at rescue station in Subsea tunnel (해저터널 구난역 열차화재시 압축공기포(Compressed Air Foam) 소화설비의 적용성 평가 실험)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.413-418
    • /
    • 2016
  • Recently, a mega project such as Korea-China or Korea-Japan undersea tunnel project has been emerged for detail discussion and the interest in undersea tunnel is on the rise. More severe damage by train fire is expected in undersea tunnel comparing to ground tunnel and thus the study on more efficient fire extinguishing system, besides existing disaster prevention design is underway. To that end, a full-scale fire tests using CAF fire extinguishing system which has been developed by modifying traditional foam fire extinguishing system for fire suppression at rescue station in timely manner were conducted over 7 times. The test was conducted after setting the rescue station in virtual tunnel with a car of KTX. As a result of using compressed air foam directly to the fire source, 30 liter of Heptane combustibles was extinguished within 1 minutes. Applicability of compressed air foam to train fire at rescue station in undersea tunnel was has been proven and further study is considered required while changing the nozzle angle and location so as to achieve quick and easy extinguishing goal, making use of the advantage of CAF, as well as to reduce the fire water and chemicals required.

The Study of TCE Dechlorination using Geobacter lovleyi with Slow Release Substrate Applied (Slow Release Substrate를 이용한 Geobacter lovleyi의 TCE 탈염소화 연구)

  • Cha, Jae Hun;An, Sang Woo;Park, Jae Woo;Chang, Soon Woong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.9
    • /
    • pp.53-59
    • /
    • 2012
  • This study investigated characteristics of decomposition of tetrabutoxysilane (TBOS) as a slow release substrate (SRS) and on effect of TBOS decompostion compounds (acetate and butylate) for anaerobic dechlorination of trichloroethylene (TCE). In the batch experiment, TCE, cis-dichloroethene (cis-DCE), 1-butanol and TBOS were analysed by GC/FID and acetate and butylate were measured by HPLC. 1M of TBOS transferred and accumulated 4M of 1-butanol by abiotically hydrolysis reaction. The hydrolysis rate was in a range of 0.186 ${\mu}M/day$. On other hand, 1-butanol fermented to butyrate and acetate with indigenous culture from natural sediments. This results showed that TBOS could be used a slow release substrate in the natural sites. The dechlorinated potential of TCE with acetate and butyrate was increased with a decreasing initial TCE concentrations. In addition, first order coefficients of dechlorination with acetate as electron donor was higher then that with butyrate. It is because that dechlorination of Geobacter lovleyi was affected by substrate affinity, biodegradability and microbial acclimation on various substrates. However, dechlorinated potential of Geobacter lovleyi was decreased with accumulation cis-DCE in the anaerobic decholoronation process. The overall results indicated that SRS with Geobacter lovleyi might be a promising material for enhancing dechlorination of TCE on natural site and cis-DCE should be treated by ZVI as reductive material or by coexisting other dechlorinated bacteria.