The Effect of Input Noise for Directional Frequency Response Functions (방향성 주파수 응답함수에서 입력 잡음의 영향)

  • Kang, Sung-Woo;Seo, Yun-Ho;Lee, Chong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.735-741
    • /
    • 2008
  • Identification of asymmetry and anisotropy of rotor system is important for diagnosis of rotating machinery. Directional frequency response functions (dFRFs) are known to be a powerful tool in effectively detecting the presence of asymmetry or anisotropy. In this paper, an input noise effect of dFRFs for rotors is estimated, when both asymmetry and anisotropy are present. The normalized random errors of the dFRFs are calculated to verify the validity of the method, which is demonstrated by numerical simulation with a simple rotor model.

  • PDF

Damage Value Calculation of Fuel Tank Considering Modal Characteristics (모달특성을 고려한 Fuel Tank의 손상도 계산)

  • Han, Woo-Sub;Park, Kwang-Seo;Kim, Young-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.534-538
    • /
    • 2008
  • The vehicle system is exposed to random source in service. Therefore, it is important to consider dynamic effect of the system. But, fatigue analysis is traditionally performed by using time signal of loading. To obtain dynamic effect of resonance, we carried out resonance durability analysis with frequency response and the dynamic load on frequency domain. The study shows that the damage considering resonant frequency of fuel tank system can be effectively estimated.

  • PDF

Vibration analysis and diagnosis of air-compressor (공기압축기의 진동분석 및 진단)

  • Lee, J.H.;Kim, B.S.;Gu, D.S.;Kim, H.J.;Choi, B.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.994-999
    • /
    • 2008
  • The necessity of diagnosis of the rotating machinery which is widely used in the industry is increasing. Because vibration diagnosis can avoid sudden breakdown of machine and reduce the maintenance costs. In the factory, Air-Compressor which can affect the performance and capacity of output is important machine. Therefore, in this paper, The measuring and analyzing is carried out for air-compressor in order to the factor of resonance and resonance avoidance for air-compressor. The result of diagnosis and solution is discussed in this paper.

  • PDF

Estimation of Directional Frequency Response Functions for Asymmetric Rotor with Anisotropic Stators (비대칭성과 비등방성이 공존하는 회전체에서의 방향성 주파수 응답 함수 추정)

  • 서윤호;강성우;서정환;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.681-686
    • /
    • 2004
  • Identification of asymmetry and anisotropy of rotor system is important for diagnosis of rotating machinery. Directional frequency response functions (dFRFs) are known to be powerful tool in effectively detecting the presence of asymmetry or anisotropy. In this paper, an estimation method of dFRFs for rotors is newly developed, when both asymmetry and anisotropy are present. The method transforms the finite degrees-of-freedom time-varying linear differential equation of motion to an infinite degree-of-freedom time-invariant linear one, employing the modulated coordinates. The validity of the method is demonstrated by numerical simulation with a simple rotor model.

  • PDF

Seismic Response Analysis of Steam Turbine-Generator Rotor System(1st Report, In case of rotor-bearing system only) (증기터빈$\cdot$발전기축계의 지진응답해석(제 1 보, 로터$\cdot$베어링시스템만을 고려한 경우))

  • 양보석;김용한
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.554-564
    • /
    • 1999
  • This paper presents the analytical method to evaluate the seismic responses on steam turbine-generator rotor system. Deterministic analytical methods, such as response spectrum approach, modal superposition method and direct integration method, are used to calculate the seismic response. The computer software is also developed based on the methods then can be applied to estimate the seismic safety of turbine-generator rotor system for power plants. Numerical example of a steam turbine-generator rotor system of 1007MW nuclear power plant is presented. The aseismatic performance are checked by comparing maximum seismic deflection at bearing positions with bearing clearance.

  • PDF

A Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen (ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석)

  • Kim, Chang-Won;Lee, Young-Shin;Kim, Heung-Tae;Kim, Jee-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the safety of the driving gear reducer of ESW(essential service water) traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in operating basis earthquake(OBE) and safe shutdown earthquake(SSE), which were applied as design condition using floor response spectrum( FRS). The maximum strain of gear reducer under OBE and SSE were 20.4 ${\mu}$ and 33.6 ${\mu}$, respectively. The maximum stresses were 2.42 MPa under OBE condition and 4.36 MPa under SSE condition, which were smaller than the allowable strength of material.

Radiated Sound from Compliant and Viscoelastic Plates in a Turbulent Boundary Layer (난류 경계층에서 컴플라이언트 코팅된 벽면과 점탄성 벽면의 방사 소음에 관한 실험적 연구)

  • Lee, Chang-Jun;Lee, Seung-Bae;Kwon, O-Sup;Jun, Woo-Pyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.294-301
    • /
    • 2003
  • We examine a problem in which porous/viscoelastic compliant thin plates are subject to pressure fluctuations under transitional or turbulent boundary layer. Measurements are presented of the frequency spectra of the near-field pressure and radiated sound by compliant surface. A porous plate consisting of 5mm thick. open-cell foam with fabric covering and a viscoelastic-painted plate of 1mm thick over an acoustic board of 4mm thick were placed over a rigid surface in an anechoic wind tunnel. Streamwise velocity and wall pressure measurements were shown to highly attenuate the convective wall pressure energy when the convective wavenumber (k$_{c}$h) was 3.0 or more. The sound source localization on the compliant walls is applied to the measurement of radiated sound by using an acoustic mirror system.

Shock Resistance Analysis of a Propulsion Motor for Naval Vessels (함정용 추진전동기의 내충격성 해석)

  • Bae, Sung-Wook;Hong, Chin-Suk;Jeong, Weui-Bong;Park, Young-Su;Bin, Jae-Goo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1183-1189
    • /
    • 2010
  • Shock-resistance test for a real equipment for a normal vessel is one of the difficult problem in many cases because of terrible cost and weight. An analysis technique to evaluate the shock resistance in a design stage is necessary, instead In this paper, the process to evaluate the shock resistance of a propulsion motor for naval vessels was presented based on German navy's BV043 regulation. The shock signal to impose the equipment under the test was first evaluated, and was then applied to the structural FE model of the equipment. From the transient FEA, the time history of von-Mises stress was obtained by the mode superposition method. The shock resistance was evaluated using the peak value of the von-Mises stress.

Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen (ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석)

  • Kim, Chang-Won;Lee, Young-Shin;Kim, Heung-Tae;Kim, Jee-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.731-736
    • /
    • 2011
  • In this study, the safety of the driving gear reducer of ESW traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE), which was applied as design condition using Floor Respnse Spectrum(FRS). The maxsimum displacement of gear reducer under OBE and SSE were 0.0137 mm and 0.0241 mm, respectively. The maximum stress of gear reducer under OBE and SSE were 2.42 MPa and 4.36 MPa, respectively.

  • PDF

Seismic Analysis of Power Plant Piping System (발전소 배관계의 내진해석)

  • Kim, Jeong-Hyun;Lee, Young-Shin;Kim, Yeon-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.480-485
    • /
    • 2011
  • In this study, the seismic analysis of power plant piping system was performed using finite element model. This study was performed by ANSYS 12.1. For qualification of power plant piping system, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. The maximum stresses of power plant piping system were 166 MPa under OBE condition and 281 MPa under SSE condition. Thus, it can shown that the structural integrity of tpower plant piping system has a stable structure for seismic load conditions.

  • PDF