• Title/Summary/Keyword: 소음 수준

Search Result 327, Processing Time 0.023 seconds

Installation of Sound Barrier to Prevent Damage to Structures Caused by Artillery Fire Impact Sound (포 사격 충격음의 구조물 손상 방지를 위한 방음벽 설치 방안)

  • Park, June;Ha, Yonghoon
    • Journal of the Korea Society for Simulation
    • /
    • v.30 no.3
    • /
    • pp.31-39
    • /
    • 2021
  • During artillery fire, an excessive level of impulse noise propagating in the form of a storm wave is generated. Since the sound of impact from the fire affects the stability of the surrounding structures, the artillery and the structures must be separated from each other by the proper distance to avoid damages from friendly fire. However, if they have already been built within the distance, it is possible to prevent the damages by building sound barriers between them. In this study, the proper separation distance between the artillery and the structure was calculated, and the insertion losses due to various heights and shapes of the sound barrier were simulated by using the BEM(Boundary Element Method), and conclusively the optimal sound barrier was selected.

Fuel Injection Strategy for Optimized Performance in Heavy-Duty Diesel Engine (대형 디젤 엔진에서 최적 성능 도출을 위한 연료 분사 전략에 관한 연구)

  • Lee, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.33-39
    • /
    • 2019
  • The improvement of emissions, fuel economy, and combustion noise is a primary target in the development of heavy-duty diesel engines. Multiple injection has been introduced as one of the most promising strategies for this goal. In this research, various multiple injection methods were applied to achieve the optimal strategy in terms of emissions, fuel economy, and combustion noise. In the case of one pilot injection, the smoke emission deteriorated, while the NOx emission was reduced. In the case of 2 pilot injections, the NOx and smoke emissions were reduced by 73% and 84%, respectively. In this case, the combustion noise was analyzed with the maximum pressure-rise rate, and the fuel economy was evaluated with the help of the indicated specific fuel consumption. A 15%:15% 2-pilot injection strategy accomplished improvements of 32.9% for NOx, 60.4% for smoke, 1.95% for fuel consumption, and 19.4% for combustion noise compared to the case of single injection. Based on the data, an optimal injection strategy will be developed for a greater operating range in future work.

A study on A-pillar & wiper wind noise estimation using response surface methodology at design stage (반응면 기법을 이용한 A필라/와이퍼 풍절음 예측 연구)

  • Rim, Sungnam;Shin, Seongryong;Shin, Hyunsu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.292-299
    • /
    • 2018
  • The vehicle exterior design is the main parameter of aerodynamic wind noise, but the modification of it is nearly impossible at a proto-type stage. Therefore, it is very important to verify exterior design and estimate the correct wind noise level at the early vehicle design stages. The numerical simulations of aerodynamic wind noises around A-pillar and wiper were developed for specific vehicle exterior designs, but could not be directly used for the discussions with designers because these need complex modeling and simulation process. This study proposes new approach to A-pillar and wiper wind noise estimation at design stage using response surface methodology of modeFRONTIER, of which database is composed of PowerFLOW simulation, PowerCLAY modeling, SEA-Baced (Statistical Energy Analysis-Based) interior noise simulation, and turbulent acoustic power simulation. New design parameters are defined and their contributions are analyzed. A state-of-the-art, easy and reliable CAT (Computer Aided Test) tool for A-pillar and wiper wind noise are acquired from this study, which shows high usefulness in car development.

Rotor Hub Vibration Reduction Analysis Applying Individual Blade Control (개별 블레이드 조종을 통한 로터 허브 진동 저감 해석)

  • Kim, Taejoo;Wie, Seong-Yong;Kim, Minwoo;Lee, Dong-geon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.8
    • /
    • pp.649-660
    • /
    • 2021
  • Through analytical method based on S-76 model, the level of rotor hub vibration reduction was analyzed according to higher harmonic actuating by individual blade control. The higher harmonic actuating method for individual blades was divided into a method of generating an additional actuating force from the pitch-link in the rotating part and generating actuating force through the active trailing edge flap control of the blade. In the 100kts forward flight conditions, the hub load analysis was performed by changing the phase angle of 15 degree for the 2P/3P/4P/5P harmonic actuation for individual blades. Through the harmonic actuation results, the sensitivity of the rotor system according to the actuating conditions was analyzed, and the T-matrix representing the characteristics of the rotor system was derived based on this analysis result. And through this T-matrix, optimal higher harmonic actuating condition was derived to minimize hub vibration level for flight condition. In addition, the effect on the performance of the rotor system and the pitch-link load under minimum hub vibration condition, as well as the noise influence through the noise analysis were confirmed.

Development of a Pavement Cutter for Eco-friendly Road Excavation Construction (친환경 도로굴착 시공을 위한 도로절단기 개발)

  • Kim, Kyoontai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.6
    • /
    • pp.111-118
    • /
    • 2022
  • Recently, as underground facilities buried under roads in Korea are aging, the amount of underground facility maintenance work is rapidly increasing. For the maintenance and management of such underground facilities, the cutting work of the road pavement should be preceded. However, the conventional road pavement cutters used in Korea are not eco-friendly, and the reality is that they generate a lot of noise and cutting sludge (scattering dust). Therefore, in this study, the concept of the cutting sludge recovery device was derived, and an eco-friendly pavement cutter including this function was designed and manufactured. The developed equipment took about 20 to 30 seconds to cut 1m to a depth of 100 to 150mm. Also, the sludge suction performance was good in most sections, and the noise level of the equipment briefly measured at a distance of 2m was 82.7dB on average. However, due to the limitation that the developed equipment was at the level of the first prototype, the driving stability was somewhat low, and equipment abnormalities such as engine shutdown and sludge recovery performance decreased in some cases. The cutting performance and sludge recovery function will be more stable through tuning and improvement of the developed prototype in the future. In addition, we plan to quantitatively compare and analyze productivity by applying the improved prototype to actual field conditions.

Measurement and Discrimination Method for the Evaluation of Aero-Pulsation Noise Generated by the Turbocharger System (터보차저의 공기맥동음 평가를 위한 측정 및 판별법)

  • Kim, Jae-Heon;Lee, Jong-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.361-365
    • /
    • 2007
  • Aero-pulsation noise, generally caused by geometric asymmetry of a rotating device, is one of considerable sources of annoyance in passenger cars using the turbocharged diesel engine. Main source of this noise is the compressor wheel in the turbocharger system, and can be reduced by after-treatment devices such as silencers, but which may increase the manufacturing cost. More effective solution is to improve the geometric symmetry over all, or to control the quality of components by sorting out inferior ones. The latter is more simple and reasonable than the former in view of manufacturing. Thus, an appropriate discrimination method should be needed to evaluate aero-pulsation noise level at the production line. In this paper, we introduce the accurate method which can measure the noise level of aero-pulsation and also present its evaluation criteria. Besides verifying the reliability of a measurement system - a rig test system-, we analyze the correlation between the results from rig tests and those from vehicle tests. The gage R&R method is carried out to check the repeatability of measurements over 25 samples. From the result, we propose the standard specification which can discriminate inferior products from superior ones on the basis of aero-pulsation noise level.

Optimization of impeller blade shape for high-performance and low-noise centrifugal pump (고성능 저소음 원심펌프 개발을 위한 임펠러 익형 최적설계)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Tae-hoon Kim;Junhyo Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.519-528
    • /
    • 2023
  • The aim of this study was to enhance the flow rate and noise performance of a centrifugal pump in dishwashers by designing an optimized impeller shape through numerical and experimental investigations. To evaluate the performance of the target centrifugal pump, experiment was conducted using a pump performance tester and noise experiment was carried out in a semi-anechoic chamber with microphones and a reflecting wall behind the dishwasher. Through the use of advanced computational fluid dynamics techniques, numerical simulations were performed to analyze the flow and aeroacoustics performance of our target centrifugal pump impeller. To achieve this, numerical simulations were carried out using the Reynolds-Average Navier-Stokes equations and Ffowcs-Willliams and Hawkings equations as governing equations. In order to ensure the validity of numerical methods, a thorough comparison of numerical results with experimental results. After having confirmed the reliability of the current numerical method of this study, the optimization of the target centrifugal pump impeller was conducted. An improvement in flow rate was confirmed numerically, and a manufactured proto-type of the optimized model was used for experimental investigation. Furthermore, it was observed that by applying the fan law, we could effectively reduce noise levels without reducing the flow rate.

A Comparative Study on Factors Influencing Residential Satisfaction by Types of Public Rental Housing (공공임대주택 유형별 주거만족도 영향요인 비교연구)

  • Mee-Jung Lee;Chan-Ho Kim;Chang-Soo Lee
    • Land and Housing Review
    • /
    • v.15 no.1
    • /
    • pp.39-55
    • /
    • 2024
  • The aim of this study is to analyse housing satisfaction among residents of different types of public rental housing-permanent, national, and happy housing-following the integration of housing types upon the full-scale supply of integrated public rental housing. By identifying key factors that influence residential satisfaction, our goal is to inform the planning of public rental housing complexes and derive policy implications. The study focuses on analysing discrepancies in residential satisfaction among residents of different types of public rental housing and comparing the factors influencing this satisfaction. Microdata from the Ministry of Land, Infrastructure, and Transport's 'Housing Situation Survey' in 2021 is utilized for analysis, employing one-way ANOVA and binomial logistic regression methods. Empirical analysis reveals variations in residential satisfaction levels between residents of permanent and national rental housing, with national rental housing residents exhibiting higher satisfaction. The influencing factors of overall condition satisfaction are consistent for permanent and national rental residents but differ for happy housing residents. Additionally, the influencing factors of overall residential environmental satisfaction vary across all three housing types. Nonetheless, common factors across all types include housing noise and facility accessibility, highlighting their significance in complex planning. Subsequent studies may involve time series analysis to assess changes in influencing factors over time.

Environmental Effects and Characteristics of Ground Vibration Caused by Tunnel Blasting in the Vicinity of an Apartment (터널 발파로 인한 아파트 인근지역에서의 지반진동 전파특성 및 영향 평가 연구)

  • 최병희;류창하;백승규
    • Explosives and Blasting
    • /
    • v.22 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Explosive blasting in tunnel excavation produces ground vibration and air blast as its side effects, which may cause complaints from nearby residents. This study was intended to investigate the propagation characteristics of ground vibration induced by tunnel blasting and to evaluate its effects on the residential structures near the site. We have conducted field measurements for 6 blasts and acquired vibration data from 70 measuring points, some of which on positioned inside the tunnel for comparative reason. Various documentation was reviewed to determine an allowable level of peak particle velocity for the residential structures in the area and the allowable limit was set to 0.5 cm/sec. Propagation equations for peak particle velocities were derived from regression analyses using the data acquired at both the surface and the underground tunnel. Finally we proposed appropriate predictive equations for the two areas and a safe blasting criterion.

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.