• Title/Summary/Keyword: 소음의 감쇠

Search Result 537, Processing Time 0.023 seconds

Distance Attenuation of Bending Wave to Analyze the Loose Parts Impact Signal (금속파편 충격 신호분석을 위한 굽힘파의 거리 감쇠)

  • Lee, Jeong-Han;Park, Jin-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.594-601
    • /
    • 2016
  • Mass estimation analysis of loose-parts in pressure vessel is necessary for the structural integrity assessment of pressure boundary in nuclear power plants. Mass of loose-parts can be generally estimated from the peak values and the center frequency of impact signals. Magnitude of impact signals is, however, inevitably attenuated according to the traveling distance of the signals and depending on the frequencies. Attenuation rate must be therefore carefully compensated for the precise estimation of loose-part mass. This paper proposes a new compensation method for the attenuation rate based on Bessel function instead of Hankel function in conventional method which has a limitation of usage in near the impact location. It was verified that the suggested compensating equation based on the Bessel function can be applied to the attenuation rate calculation without any limitation.

Damping Effects of a Flexible Structure Interacting with Surrounding Acoustic Fluid (주변 음장과 연동하는 탄성 구조체의 감쇠 효과)

  • Lee, Moon-Seok;Park, Youn-Sik;Park, Young-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.718-724
    • /
    • 2008
  • A flexible structure submerged in acoustic fluid is affected by its surrounding fluid. In this case, the coupling effects between structures and surrounding fluid have an effect on the submerged structure as external force and change impedance of acoustic domain. Therefore, the coupling effects by its surrounding fluid complicatedly change the characteristics of a submerged structure such as natural frequencies and damping coefficients. In this paper, using the analytic modal equation of a spherical shell surrounded by water and air, the complex changes of damping coefficients and natural frequencies of submerged structures are studied for various external acoustic fluid and structures.

Sound Reduction Index of Interior Door by Aperture Sizes at Door's Bottom (하부틈새 크기에 따른 도어의 음향감쇠계수 분석)

  • Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.834-840
    • /
    • 2010
  • The Sound reduction indices(SRIs) of interior door with 13 different size apertures are measured in acoustic chamber. Also, as a theoretical approach, the SRIs are estimated using Gomperts' theory. In this study, the aperture of interior door is focused on the lower part of door leaf which is well known as a main cause to deteriorate the sound insulation performance of door. The results show that the SRI of door strongly depends on the aperture width and the dip in the measured sound reduction index curve by the resonance effect within aperture is observed at high-frequency. On the whole, the values calculated by theory are in good agreement with the measured values including the position of resonance dip. The average difference between the measured and the calculated values is 0.9 dB for 13 doors with different size aperture in terms of the weighted SRI.

Damping Estimation of Railway Bridges Using Extended Kalman Filter (확장형 칼만 필터를 이용한 철도교의 감쇠비 분석)

  • Park, Dong-Uk;Kim, Nam-Sik;Kim, Sung-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.3
    • /
    • pp.294-300
    • /
    • 2009
  • In high speed railway bridges, dynamic analysis is important because of high passing velocity and moving load at the regular intervals, and damping ratio is a major parameter to predict dynamic responses. In this paper, damping ratios were estimated by using half power band width method and extended Kalman filter according to acceleration signal conditions, and a relationship between estimated damping ratios and representative values of bridge vibration was derived. From the results, damping ratios estimated from total ambient vibration were more reliable than only free vibration part. In case of using extended Kalman filter, the estimated damping ratios varying with RMQ(root mean quad), as one of representative values of bridge vibration, have more feasible trend. Thus, it is shown that further studies on reliabilities of estimated damping ratios are needed.

The Study on the Improvement on Damping Ratio of Dynamic Absorber using Silicon Oil (실리콘 오일을 이용한 동흡진기 감쇠 성능 향상에 대한 연구)

  • Kwak, Y.S.;Kim, W.H.;Joo, W.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.113-118
    • /
    • 2011
  • Many kinds of dynamic absorbers have been used to reduce the vibration of machineries and structures. In the typical ones, however low damping capacity, durability and limited install condition restrict their application. In this study, high damped dynamic absorber was proposed for diesel generator set. Developed absorber is composed with mass and coil springs. Silicone oil was filled inside the narrow gap between mass and casing. Viscous damping of silicon oil act as additional damping so that proposed dynamic absorber is suitable for D/G set which have adjacent resonance frequency to operation speed. The performance of the dynamic absorber was confirmed through the actual test on diesel engine generator set.

  • PDF

Experimental research of dynamic behaviors at viscoelastic damper with change of orifice (점탄성 감쇠기의 간극 변화에 따른 동특성에 대한 실험적 연구)

  • Yun, Jong-Min;Lim, Sang-Hyuk;Park, Hwa-Yong;Kim, Chang-Yeol;Lee, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.744-749
    • /
    • 2011
  • Silicon oil in viscous fluid damper has a viscoelastic feature that show stiffness besides damping. These properties depend on frequency and are non-linear. A lot of research has been conducted in order to identify viscoelastic damper with mathematical model. Fractional Derivative Maxwell Model has been widely used, but this model did not explain the effect of damper size change on the damper performance. In this paper, the experimental study was conducted to validate damper's dynamic behaviors when total damper's size is changed while maintaining same aspect ratio and orifice size.

  • PDF

Damping Properties of Plastic with Temperature Variation (온도변화에 따른 플라스틱의 진동감쇠특성)

  • Shin, Su-Hyun;Jung, Sung-Soo;Lee, Yong-Bong;Lee, Doo-Hee;Nam, Hyo-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.213-218
    • /
    • 2005
  • It is well known that the loss factor and Young's modulus are fundamental mechanical properties of materials. Recently, the use of complex plastics is increasing for vibration proof. In this study, we evaluated two mechanical values of polycarbonate and acrylonitrile butadiene styrene by using two different standard test methods of ASTM E 756 and ISO 6721. Because damping properties of material generally depend on temperature, test specimen‘s temperature were controlled in the temperature range between - $10^{\circ}C\;and\;60^{\circ}C$. The results shown that the loss factor of polycarbonate gradually increased as increasing temperature, while the Young's modulus decreased. However, the loss factor and the Young's modulus of acrylonitrile butadiene styrene are varied somewhat at $60^{\circ}C$.

Seismic Protection of Cable-stayed Bridges Using LRB and MR Damper (납-고무받침과 자기유변유체 감쇠기를 이용한 사장교의 내진제어)

  • 정형조;박규식;이인원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.241-245
    • /
    • 2003
  • This paper presents the LRB-based hybrid base isolation system employing additional semiactive control devices for seismic protection of cable-stayed bridges by examining the ASCE first generation benchmark problem for a cable-stayed bridge. In this study, ideal magnetorheological dampers (MRDs) are considered as additional semiactive control devices. Numerical simulation results show that the hybrid base isolation system is effective in reducing the structural responses of the benchmark cable-stayed bridge under the historical earthquakes considered. The simulation results also demonstrate that the hybrid base Isolation system employing semiactive MRDs is robust to the stiffness uncertainty of the structure. Therefore, the LRB-based hybrid base isolation system employing MRDs could be appropriate in real applications for full-scale civil infrastructures.

  • PDF

Experimental Study on Energy Dissipation Capacities of the Viscous Damping Wall (벽식점성감쇠기의 감쇠 성능에 관한 기초적인 연구)

  • 이장석;김남식;조강표
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.246-251
    • /
    • 2003
  • This paper presents an experimental study on the energy dissipation characteristics of viscous damping wall (VDW). VDW is consisted of a plate floating in a thin case made of steel plated filled with highly viscous silicone oil. Because VDW demonstrates both viscous damping and stiffness characteristics, the viscous resisting force can be expressed as the sum of velocity dependant viscous damping force and displacement dependant restoring force. The viscous resisting force and energy absorbing capacity can be easily adjusted by changing three factors, i.e. viscosity of the fluid, gap distance and area of the wall plates. VDW was tested using a series of harmonic (sinusoidal) displacement history having different frequency and amplitude and the force-displacement relationship was recorded. The relationship between dissipated energy with three factors and the influence of exciting frequency on resisting force were Investigated

  • PDF

Test method comparison for vibration-damping of materials (물질의 진동감쇠 시험법 비교)

  • 신수현;이용봉;정성수;조승일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.700-703
    • /
    • 2003
  • The test method of ASTM E 756 and KS D 0076 to estimate vibration-damping properties is compared. Comparison method depending on specimen support, exciting method and calculation method for loss factor is used. Half-power bandwidth method and vibration decay method is used in the calculation method for loss factor, and Young's modulus is decided by geometric character and density for specimen and resonance frequency. Vibration measurement sensor is compared by using non-contact displacement detector, velocity detector and accelerometer. This paper is also presented the matter which is able to cause error in the measurement

  • PDF