• Title/Summary/Keyword: 소아 CT

Search Result 312, Processing Time 0.021 seconds

Basic Principles of CT Dose Index and Understanding of CT Parameter for Dose Reduction Technique (CT선량지표의 원리와 선량감소 방안에 관한 연구)

  • Kim, Jung-Su;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.51-61
    • /
    • 2015
  • Computed tomography(CT) using radiation have potential risks. All medical radiographic examinations should require the justification of medical imaging examinations and optimization of the image quality and radiation exposure. The CT examination was higher radiation dose then general radiography. Especially pediatric CT examinations need to great caution of radiation risk. Because of pediatric patient was more sensitive of radiation exposure. Therefore, physician should consider the knowledge of CT radiation exposure indicator information for reduce a needless radiation exposure. This article was aim to understanding of CT exposure indicator, size-specific dose estimates by American Association of Physicists in Medicine (AAPM) report 204, XR 25 and understanding of CT dose reduction technique.

Root and Canal Morphology of Maxillary Primary Molar using CBCT and 3D CT (CBCT 및 3D CT를 활용한 상악 유구치 치근과 근관 형태)

  • Kim, Joon Hee;Kim, Hyuntae;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Song, Ji-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.437-448
    • /
    • 2021
  • The purpose of this study is to analyze morphological characteristics of maxillary primary molar's root and root canal. 268 children aged 3 - 7 years (175 boys, 93 girls) who had CBCT (152 children) and 3D CT (116 children) taken in Seoul National University Dental Hospital from January 2006 to April 2020 were included. The number of roots and root canals were analyzed in 1002 teeth without any root resorption or periapical pathologies. Curvature, angulation, length of root and root canal, as well as cross-sectional shapes of the root canal were analyzed in 218 teeth. By using Mimics and 3-Matics software, volume, surface area, and volume ratio of root canal was analyzed in 48 teeth. More than half of maxillary primary molars have 3 roots and 3 root canals. The degree of symmetry of root canal type was about 0.63 (Cohen's kappa coefficient). The most frequent shape of roots and canals was linear in 1st primary molars and curved in 2nd primary molars. Angulation, length of root and root canals was the largest on palatal roots. Most teeth showed ovoid or round shapes at apex. The largest root canal volume, surface area, volume ratio was found in the palatal roots.

DIAGNOSIS AND EXTRACTION OF IMPACTED SUPERNUMERARY TEETH IN THE MAXILLA WITH 3D DENIAL-CT (3D Dental-CT를 이용한 상악 매복 과잉치의 진단 : 증례보고)

  • Kim, Su-Kyoung;Yang, Yeon-Mi;Baik, Byeong-Ju;Kim, Sung-Hee;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.91-98
    • /
    • 2006
  • Supernumerary teeth are teeth which result from the continued budding of the enamel organ of the preceding tooth or from excessive proliferation of cells. They are most often found in the maxillary anterior region. And they can be responsible for a variey of irregularities in the primary and transitional dentition. There are two morphological types of supernumerary teeth, supplemental and rudimentary. Supplemental teeth have normal shape and size. In contrast, rudimental teeth have abnormal shape and smaller size. Supplemental supernumerary teeth are most common in permanent lateral incisor area. Its extraction must be decided more carefully with differential diagnosis between normal teeth, because it has normal shape and size. We reports 3 cases of the normal incisor shaped teeth in the maxillary anterior region. In all cases, we used the 3D Dental-CT as well as the conventional plain film such as periapical, occlusal, and panoramic radiograph. Consequently, 3B Dental-CT was valualble to figure out the exact position and morphology of supernumerary teeth, to do more conservative surgery and to reduce surgery stress and time.

  • PDF

A Study of Root Canals Morphology in Primary Molars using Computerized Tomography (CT를 이용한 유구치 근관 형태에 관한 평가)

  • Sim, Dohee;Mah, Yonjoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.400-408
    • /
    • 2019
  • The purpose of this study is to identify the most common canal type in primary molars and the correlation between their roots and canals. A comprehensive understanding of root canal morphology will lead to more successful root canal treatment. Computed Tomography (CT) images from 114 children (81 boys, 33 girls) aged 3 - 7 years were obtained. The locations and numbers of roots and canals were evaluated, and the relationship between root and canal parameters was determined. The most commonly observed canal morphology in primary maxillary molars were mesio-buccal, disto-buccal and palatal canal. Primary mandibular molars most frequently contain mesio-buccal, mesio-lingual, disto-buccal and distolingual canal. All the roots of the primary maxillary molars except for the mesio-buccal root, each had 1 canal while there were 2 canals observed in each root of primary mandibular molars. Without exception, all mesial roots in primary mandibular 2nd molars had 2 canals. In case when either the palatal root in a primary maxillary molar or the distal root in a primary mandibular molar was separated into 2 roots, each root seemed to have its own canal. Even though the disto-buccal and palatal roots were fused into 1 root in primary maxillary molars, this fused root had tendency to have 2 separate canals. Primary mandibular molars showed similar canal morphologies between left and right molars in the same patient, while the primary maxillary molars did not.

Value of Repeat Brain Computed Tomography in Children with Traumatic Brain Injury (소아 두부외상 환자에서의 반복적인 두부 CT 검사의 유용성)

  • Jo, Ho jun;Lim, Yong Su;Kim, Jin Joo;Cho, Jin Seong;Hyun, Sung Youl;Yang, Hyuk Jun;Lee, Gun
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.149-157
    • /
    • 2015
  • Purpose: Traumatic brain injury (TBI) is the most common cause of pediatric trauma patients came to the emergency department. Without guidelines, many of these children underwent repeat brain computed tomography (CT). The purpose of this study was to evaluate the value of repeat brain CT in children with TBI. Methods: We conducted a retrospective study of TBI in children younger than 19 years of age who visited the emergency department (ED) from January 2011 to December 2012. According to the Glasgow Coma Scale (GCS) and Pediatric Glasgow Coma Scale score of the patients, study population divided in three groups. Clinical data collected included age, mechanism of injury, type of TBI, and outcome. Results: A Total 83 children with TBI received repeat brain CT. There were no need for neurosurgical intervention in mild TBI (GCS score 13-15) group who underwent routine repeat CT. 4 patients of mild TBI group, received repeat brain CT due to neurological deterioration, and one patient underwent neurosurgical intervention. Routine repeat CT identified 12 patients with radiographic progression. One patient underwent neurosurgical intervention based on the second brain CT finding, who belonged to the moderate TBI (GCS score 9-12) group. Conclusion: Our study showed that children with mild TBI can be observed without repeat brain CT when there is no evidence of neurologic deterioration. Further study is needed for establish indication for repetition of CT scan in order to avoid unnecessary radiation exposure of children.

  • PDF

Generalized Pulp Stones of Primary Dentition in a Patient with Molar-Incisor Malformation : A Case Report (Molar-Incisor Malformation 환자의 유치열 내 전반적인 치수석 관찰의 증례 보고)

  • Lee, Dongyun;Shin, Jisun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.337-343
    • /
    • 2020
  • Molar-incisor malformation (MIM) is a new type of root anomaly reported recently. The characteristics of MIM are dysplastic root formations, constriction of pulp chambers and presence of calcified matrices at the level of cementoenamel junction in permanent first molars and primary second molars. In some cases, permanent maxillary incisors are also affected. The permanent first molars of the patient in this case report were affected with MIM. Generalized pulp stones were observed in overall primary dentition. Micro-computed tomography (micro-CT) imaging and scanning electron microscope-energy dispersive X-ray spectrometer analysis were performed on the extracted mandibular first molar and maxillary primary second molar of the patient. Micro-CT images revealed the discontinuity of enamel directly connected to an accessory canal of the root.

Comparison Study with Pain Assessment Tools of Pain Measurement in Children for Intravenous Catheter Placement in the Computed Tomography (CT 검사에서 소아 환자의 정맥 카데터 삽입 통증에 대한 측정 도구 비교)

  • Kweon, Dae-Cheol;Jang, Keun-Jo
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.205-212
    • /
    • 2008
  • Needle phobia of medical devices is a significant problem in children patients. We conducted study in 130 pediatric patients aged $8{\sim}13$(mean age 10.5) who had venipuncture performed in a computed tomography. This review aims to explore the research available relating to three commonly used pain rating scales of children, the visual analogue scale(VAS), numeric pain rating scale(NPRS) and Wong-Baker faces pain scale(WBFPS) with scores. Its validity is supported by a strong positive correlation with the three-pain rating scales(correlations ranging from 0.70 to 0.92) measure in children. There were no significant differences between the means on the VAS and either of the pain rating scales. It has the advantage of being suitable for use with the most widely used metric for scoring($0{\sim}10$), and conforms closely to a linear interval scale. These scales presented moderate to good correlation and moderate agreement, sufficient for valid use in children. All three pain-rating scales are valid, reliable and appropriate for use in intravenous catheter placement.

Usefulness of Ultrasonographic Examination by a Pediatrician in Children with Abdominal Pain (소아 복통에서 소아과 의사에 의한 초음파 검사의 유용성)

  • Park, Hyun-Seok;We, Ju-Hee;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • Purpose: Ultrasonography (US) is widely used as a screening test in patients with abdominal pain (AP). We investigated the usefulness of US by a pediatrician in children with AP. Methods: We retrospectively analysed the medical records of children with AP who undertook US from December, 2008 to July, 2010. Results: A total of 628 patients (325 male, 303 female) were enrolled in this study. The mean age of patients was $8.08{\pm}4.61$ years. Duration of AP was acute in 427 and chronic in 201 patients. Localization of AP was diffuse (36.9%), periumbilical (24.4%), epigastric (21.0%), and right lower quadrant (8.1%). On the examination, there were no abnormal findings in 327 patients (52.1%). Abnormal ultrasonographic findings were mesenteric lymphadenitis (27.1%), intestinal mural thickening (10.0%), intussusception (3.0%), appendicitis (2.6%), choledochal cyst (1.6%), and pancreatitis (0.3%). We performed additional imaging studies such as computed tomography (CT) or magnetic resonance imaging (MRI) in 39 patients who showed obscure findings on the US. In 33 patients (84.6%), the same results were obtained from CT or MRI. Two cases of appendicitis, one case of pancreatitis and one case of Henoch-Sh$\ddot{o}$nlein purpura were diagnosed by the CT examination. However, there were two cases of appendicitis diagnosed by US thathad no evidence of appendicitis on the CT. Diagnostic accuracy of initial US in children with abdominal pain was 99.4%. Conclusion: US by a pediatrician as a screening test in children with AP provides a rapid and accurate diagnostic indication and has non-invasive and radiation-free advantages.

Usefulness of DFOV Changes in Pediatric PET/CT Image Reconstruction (PET/CT에서 소아환자 영상 재구성 시DFOV 변화의 유용성)

  • Choi, Sung-Wook;Choi, Choon-Ki;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.171-175
    • /
    • 2008
  • Purpose: There have been something difficulties in locating focuses and quantitative analysis in case of pediatric patients because of the relatively small body compared to adults. This author of this study, therefore, evaluated the usefulness of DFOV (Display Field Of View) according to its changes in PET/CT image reconstruction by means of the phantom experiment and pediatric patients examination. Materials & Methods: 0.023 MBq/cc of $^{18}F$-FDG was put into the uniform NU2-94 phantom, and then emission scan was acquired for 10 minutes. For reconstruction, DFOV values were changed to 50, 45, 40, 35, 30, and 25 cm respectively. As for patient images, 20 patients who were diagnosed as the one or suspicion of the children tumor are targeted from Oct 2007 to Jan 2008. For image reconstruction, 50 cm was the basis of DFOV, and the value was adjusted to DFOV 45 cm to 25 cm respectively. In the phantom and the reconstruction image of pediatric patients, the changes in pixel size and $SUV_{max}$ according to DFOV changes were analyzed. Results: As DFOV decreased to 50, 45, 40, 35, 30, and 25 cm by means of the phantom, the pixel size was changed to 3.906, 3.515, 3.125, 2.734, 2.343, and 1.953 mm respectively. Besides, as a result of reconstruction DFOV in images of pediatric patients to 50, to 25 cm, the different values of $SUV_{max}$ are shown as 3.3, 7.3, 12, 14, 18% and 2.6, 4.3, 5.0, 7.0, 10.0% on respectively when 50 cm was the standard. Conclusion: In $SUV_{max}$ using the phantom, as DFOV decreased every 5 cm, the mean value gradually increased. With 50 cm as the standard, the increase rates were 3.7, 6.5, 11.2, 19.5, and 32.1% respectively. As for pediatric patients image too, as DFOV decreased, the rates increased as in the phantom experiment. In image reconstruction, since DFOV decrease regardless of matrix size change reduced the pixel size, the image quality can be improved. This would be more useful than reconstruction and enlarge images of pediatric patients in the same way of examining adults. However, when the value of 35 cm DFOV was applied, this may result in truncated artifact, and thus the application should be properly controlled. Change of DFOV may produce better image for pediatric patients, but changes of SUV values according to DFOV change should be considered in reading.

  • PDF

Awareness and Consciousness Survey of Worker's for Radiation Exposure Dose Reduction from Pediatric Brain CT Examination (소아두부 컴퓨터단층촬영검사에서 방사선피폭선량 저감화를 위한 근무자의 인식도와 의식도 조사)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.207-214
    • /
    • 2016
  • In this study, it was an investigation of the degree of awareness and consciousness of the radiology technicians about radiation protection working in the computed tomography room in Busan when the pediatric underwent brain CT scan. It was sorted by university hospital, general hospital and hospital and compared the scores of awareness and consciousness. As a result of awareness, university hospital had the highest point of 42.29 followed by general hospital and hospital of 38.43 and 34.06 respectively. On the other hand, the average score of consciousness was the highest in hospital of 29.19 followed by general hospital and university hospital of 24.68 and 21.37 respectively. It is considered to need assistance to cultivate an awareness of the radiation through refresher training and conferences, etc in order to increase the awareness of the general hospitals and hospitals for CT workers. In addition, it is also expected to pay for efforts to increase the consciousness of CT workers in university hospitals seeking the optimization of radiation protection and dose reduction of radiation exposure for the pediatric.