• Title/Summary/Keyword: 소산

Search Result 1,040, Processing Time 0.028 seconds

Control-Gain Estimation of Energy Dissipation Control Algorithms (에너지소산 제어 알고리듬의 제어이득 산정)

  • Lee Sang Hyun;Kang Sang Hoon;Min Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.343-350
    • /
    • 2004
  • This study is on control gain estimation of energy dissipation control algorithms. Velocity feedback saturated, bang bang, and energy gain control algorithms are proposed based on the Lyapunov stability theory and their performances are evaluated and compared. Saturation problem is considered in the design of the velocity feedback saturated and energy-gain control algorithms, and chattering problem in bang bang control is solved by using boundary layer. Numerical results show that the proposed control algorithms can dissipate the structural energy induced by wind loads efficiently.

A Study on the Optimization of Heat Dissipation in Flip-chip Package (플립칩 패키지의 열소산 최적화 연구)

  • Park, Chul Gyun;Lee, Tae Ho;Lee, Tae Kyoung;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.3
    • /
    • pp.75-80
    • /
    • 2013
  • According to advance of electronic packaging technology, electronic package becomes smaller. Miniaturization of package causes the temperature rise of package. This can degrade life of electronic device and generate the failure of electronic system. In this study, we proposed a new semi-embedded structure with micro pattern for maximizing heat dissipation. A proposed structure showed the characteristics which have maximum temperature lower than $20^{\circ}C$ compared with conventional structure. And also, in view of thermal stress and strain, our structure showed a remarkably low value compared with other ones. We expect that the new structure proposed in this work can be applied to an flip-chip package of the future.

Equivalent Damping Ratio of a SDOF Structure Combined with Coulomb and Viscous Damping (점성 및 마찰감쇠가 있는 단자유도 구조물의 등가감쇠비)

  • Seong, Ji-Young-Suck;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.449-453
    • /
    • 2010
  • 본 논문에서는 점성 및 감쇠가 있는 단자유도 구조물의 등가감쇠비를 효율적으로 구하는 방법을 제시하였다. 건물에 설치된 마찰감쇠기는 외력의 크기에 따라 정지와 운동의 상태를 반복하여 외부 입력에너지를 소산시키기 때문에 외력과 응답관계가 비선형이다. 마찰감쇠기가 설치된 단자유도 건물은 마찰감쇠기외에 점성감쇠가 동시에 존재하므로 해석적인 정해를 구하기가 어렵다. 등가감쇠비를 산정하기 위해서 첫째, 점성과 마찰감쇠가 있는 단자유도계 건물의 자유진동 정해를 통하여 변위응답과 가속도 응답특성을 분석하였다. 둘째, 자유진동의 경우 응답이 멈출 때까지 소산에너지식을 이용하여 등가점성감쇠비를 구하였다. 셋째, 조화가진 일 때는 수치해석을 통하여 마찰력비 $F_r$에 따른 응답 특성을 알아보았다. 넷째, 조화가진의 경우 에너지 균형식을 바탕으로 등가점성감쇠비를 유도하였다. 등가점성감쇠비는 변위응답비의 영향을 받으므로 응답을 알아야만 구할 수 있다. 건물 응답의 진동수 특성은 협소영역(narrow band)이므로 고유진동수에 의해 지배된다고 가정하여 등가점성감쇠비를 구하였다. 마지막으로, 유도한 자유진동과 조화가진의 등 가점성감쇠비를 이용한 등가선형운동방정식의 해를 비선형 수치해석 한 결과와 비교하여 검증하였다.

  • PDF

Capacity Development of Existing Frame by Aramid Sheet and Energy Dissipation Device (아라미드 시트와 에너지 소산 장치에 의한 기존 골조의 능력 향상)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.112-119
    • /
    • 2015
  • In this paper, the strengthening method was proposed for improving the seismic performance of the vulnerable structural frames. To improve the brittle characteristics of columns, aramid fiber sheet was used for the lateral confinement of columns. And to introduce the energy dissipation capacity, a steel damper with S-shaped struts was installed. By making the unreinforced and reinforced specimens with full size specimens were evaluated for lateral load resistance capacity. It was confirmed the strengthening effects by the evaluation of failure shape, strength, stiffness degradation, and energy dissipation capacity. Also from the FE analysis using ABAQUS, the hysteretic behavior of the specimens were predicted and evaluated.

Mineralogical Phase Transform of Salt-roasted Concentrate and Enhancement of Gold Leaching by Chlorine-hypochlorite Solution (소금-소성정광에 대한 광물학적 상변화와 염소-차아염소산 용액을 이용한 금 용출 향상)

  • Kim, Bong-Ju;Cho, Kang-Hee;Oh, Su-Ji;Choi, Seoung-Hwan;Choi, Nag-Choul;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.9-18
    • /
    • 2013
  • In order to optimize the gold leaching process from refractory sulfide concentrate, a chlorine-hypochlorite solution with varying concentrations and temperatures were applied to salt-roasted concentrate. The concentrate consisted of pyrite, chalcopyrite, and galena, which were turned into hematite through air-roasting at $750^{\circ}C$. Also these concentrates were changed into hematite and nantokite (CuCl)) through salt (NaCl)-roasting at $750^{\circ}C$. The results of the gold leaching experiments showed that the best gold leaching parameters were obtained when the hydrochloric acid-sodium hypochlorite mix was at a ratio of 1 : 2, the added concentration was 1.0 M concentration, the pulp density was 1.0%, and the leaching was done at a $60^{\circ}C$ leaching temperature. The leaching rate for gold was much greater in the roasted concentrate than in the raw concentrate. The leaching rate was greater in the salt-roasted concentrate than in the plain roasted concentrate too. From XRD analysis, quartz was found in the salt-roasted concentrate and in the solid residue from the chlorine-hypochlorite leaching solution at $60^{\circ}C$.

The Limiting Drift and Energy Dissipation Ratio for Shear Walls Based on Structural Testing (전단벽의 최소 층변위 및 에너지 소산성능)

  • ;;N.M.Hawins
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.335-343
    • /
    • 1998
  • Recently, new experimental criteria for reinforced concrete frame structures in high seismic regions have been reported in United States. The objective of the criteria is to get more reliable test data which are valid to compare with other test data done by different researchers. The criteria precribe test method of specimens, analysis method of test data, and limiting values needed to specimens like drift angle, energey dissipation ratio, stiffness, and strength. These criteria might be usefel to get objective conclusion. Shear wall structures, which belong to one of earthquake resisting systems, also need this kind of criteria. But, the general response of shear wall structures is a little bit different from that of frame structures since shear wall restrains the horizontal displacement caused by horizontal force and increases the stiffness and strength. The objective of this paper is to propose a criterion for limiting drift and energy dissipation ratio of shear walls based on structural testing. These are the most important values for presenting the capacity of shear walls. Limiting drift and energy dissipation ratios were examined for tests on shear walls having ductile type failures. Test data were analyzed and compared to the results for a suggested acceptance criteria that involve a limiting drift that is a function of aspect ratio and a limiting energy dissipation ratio that is a function of displacement ductility and damping.

A Study on the Evaluation of Smear Zone by In-situ Tests (현장시험에 의한 Smear Zone의 평가)

  • 이장덕;구자갑
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.207-216
    • /
    • 2003
  • To evaluate the smear zone caused by the drain installation, 10 piezometers were installed in the typical soft ground in the western coastal area of Korea. The dynamic pore water pressure developed during the drain installation was monitored using piezometers installed at a distance of 10cm, 20cm, 30cm, 40cm and 50cm from the location of the drain. The decay of pore pressure with time after pushing piezometers to depths of 5 meters and 7 meters during the drain installation was monitored to assess flow and consolidation characteristics of the soil after disturbance of the soil due to the drain installation. The drain installation results in shear strain and displacement of the soil and it decreases the permeability of the soil. Hence, the comparison between dissipation of the pore water pressure process in 10 pieszometers before as well as after installation of the drain indicated the diameter of disturbance zone and smear zone, which is related to the cross-sectional dimension of the mandrel. In addition, Cone-pressuremeter(CPM) tests were performed to obtain rigidity index of the soil for an interpretation of the dissipation processes. It has been evaluated by in-situ tests that the smear zone is from 3.0 to 3.6 times of the cross-sectional dimension of the mandrel. The hydraulic conductivity expressed in terms of the coefficient of consolidation after the drain installation was calculated from 3 to 8 times decrease evaluated by Teh & Houlsby equation and CPM test results.

Permeability Characteristics of Soft Clay using the Piezocone Test and a Laboratory Test (피에조 콘 시험과 실내시험을 이용한 점토지반의 투수특성 연구)

  • Gu, Nam-Sil;Kim, Young-Min;Park, Jae-Hwhan;Jang, Ji-Guen
    • The Journal of Engineering Geology
    • /
    • v.21 no.4
    • /
    • pp.349-359
    • /
    • 2011
  • The consolidation behavior of soft clay is controlled mainly by its compressibility and deformation characteristics. Soil permeability depends on various soil characteristics, including the soil type and anisotropy. The coefficient of permeability of soft clay is determined by using a laboratory test (the Oedometer test) or a piezocone test. The latter test is useful for estimating the permeability characteristics from $c_h$ and $k_h$ by performing an excess pore-pressure dissipation test. This study seeks to validate an existing theoretical formula in applying it to marine clay, and to assess the relation between $k_h/k_c$ and the mechanical properties of soft clay. Piezocone tests and laboratory tests were performed using sediment from the Yellow Sea and from the South Sea near Korea. We compared $k_h/k_v$ values obtained using the piezocone test and using laboratory consolidation tests. The obtained values are similar to the values obtained by Jamiolkowski et al. (M application); therefore, the latter values are recommended to be used as $k_h/k_v$.

Synthesis of Aminated Poly(ether imide) for the Preparation of Bi-polar Membranes and Their Application to Hypochlorite Production through the Surface Direct Fluorination (바이폴라막 제조를 위한 폴리에테르이미드의 아민화 합성 및 표면불소화를 통한 차아염소산 생성)

  • Kim, Cheong Seek;Kang, SuYeon;Rhim, Ji Won;Park, Soo-Gil
    • Polymer(Korea)
    • /
    • v.39 no.2
    • /
    • pp.338-345
    • /
    • 2015
  • Poly(phenylene oxide) (PPO) and polyether imide (PEI) were sulfonated and aminated to create sulfonated poly(phenylene oxide) (SPPO) and aminated polyether imide (APEI), respectively. Characterization of the SPPO and APEI were performed via measurements of FTIR, thermogravimetry (TGA), swelling degree, ion exchange capacity (IEC), and ion conductivity. Next, the surfaces of these membranes were modified by surface fluorination at room temperature. The surface fluorinated SPPO and APEI membranes underwent characterization again for the mentioned measurements to determine any differences. The 3 types of bi-polar membranes were prepared by varying the IEC of the APEI at a fixed SPPO IEC value, which were applied to the low and high NaCl concentration of feed solution at the different current density, respectively. The hypochlorite concentration derived from the surface fluorinated membranes was dependent on the IEC of the APEI and ranged from 491 to 692 ppm at $80mA/m^2$. At low current density of $5mA/m^2$, the hypochlorite concentrations ranged from 18 to 28 ppm for the 4 hrs surface fluorinated membranes and their durability increased greatly.

The Characteristic of Te Recovery in Gold Concentrate Using Electrolysis (전기분해법을 이용한 금정광내 Te 회수 특성)

  • Kim, Bong-Ju;Cho, Kang-Hee;Jo, Ji-Yu;Choi, Nag-Choul;Park, Cheon-Young
    • Economic and Environmental Geology
    • /
    • v.47 no.6
    • /
    • pp.645-655
    • /
    • 2014
  • In order to obtain pure metallic Te from gold concentrate, roasting treatment, hypochlorite leaching, Fe removal and electrolysis experiments were carried out. The contents of Au, Ag and Te from the concentrate sample and roasted sample were much more soluble in the hypochlorite solution than in aqua regia digestion, whereas the metals Pb, Zn, Fe and Cu were easier to leach with the aqua regia than the hypochlorite. With the addition of NaOH in the hypochlorite leaching solution prior to electrolysis, the Fe removal rate achieved was only 96% in the concentrate sample, while it reached 98% in the roasted sample. The results of electrolysis for 240 min, 98% of the metallic copper was recovered from the concentrate sample, while 99% was obtained from the roasted sample due to the removal of S by roasting. The amount of anode slime was also greater in the electrolytic solution with the roasted sample than with the concentrate sample. The results on the anode slime after the magnetic separation process showed the amount of metallic pure native tellurium recovered was greater in the roasted sample than in the concentrate sample.