• Title/Summary/Keyword: 소모전력 분석

Search Result 524, Processing Time 0.026 seconds

Protection Profile for Smart Meters: Vulnerability and Security Requirements Analysis (스마트미터의 취약성/보안요구사항 분석 CC v3.1 기반 보호프로파일 개발)

  • Jung, Chul-Jo;Eun, Sun-Ki;Choi, Jin-Ho;Oh, Soo-Hyun;Kim, Hwan-Koo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.6
    • /
    • pp.111-125
    • /
    • 2010
  • There is a growing interest in "smart grid" technology, especially after the government recently announced "low-carbon green-growth industry" project. A smart grid uses "smart meters", which can be deployed in any power-consuming places like homes and factories. It has been shown that smart meters have several security weaknesses. There is, however, no protection profile available for smart meters, which means that safety with using them is not guaranteed at all. This paper analyzes vulnerabilities of smart meters and the relevant attack methods, thereby deriving the security functions and requirements for smart meters. Finally, we propose a protection profile based on Common Criterion v3.l for smart meters.

Delay time Analysis of Asynchronous RIT Mode MAC in Wi-SUN (Wi-SUN에서 비동기 RIT모드 MAC의 지연시간 분석)

  • Dongwon Kim;Mi-Hee Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.2
    • /
    • pp.65-70
    • /
    • 2024
  • In recent years, research on smart factory wireless mobile communication technology that wirelessly remotely controls utilities is being actively conducted. The Wi-SUN (Wireless Smart Utility Network) Alliance proposed a Wi-SUN protocol structure suitable for building a platform such as a smart factory as a new wireless communication standardization standard based on EEE802.15.4g/e. It analyzes the performance of the IEEE802.15.4e Receiver Initiated Transmission(RIT) Mode Media Access Control (MAC) in terms of throughput and latency, and looks at considerations for efficient operation. RIT mode shows that as the check interval becomes longer, delay time and throughput decrease. It was shown that as the traffic load increases, if the RIT check interval is shortened, the delay time can be shortened and throughput can be increased. RIT mode has the advantage of low power consumption and has neutral characteristics between IEEE802.15.4 and CSL mode in terms of delay time and throughput.

Analysis on the Temperature of 3D Multi-core Processors according to Vertical Placement of Core and L2 Cache (코어와 L2 캐쉬의 수직적 배치 관계에 따른 3차원 멀티코어 프로세서의 온도 분석)

  • Son, Dong-Oh;Ahn, Jin-Woo;Park, Jae-Hyung;Kim, Jong-Myon;Kim, Cheol-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.6
    • /
    • pp.1-10
    • /
    • 2011
  • In designing multi-core processors, interconnection delay is one of the major constraints in performance improvement. To solve this problem, the 3-dimensional integration technology has been adopted in designing multi-core processors. The 3D multi-core architecture can reduce the physical wire length by stacking cores vertically, leading to reduced interconnection delay and reduced power consumption. However, the power density of 3D multi-core architecture is increased significantly compared to the traditional 2D multi-core architecture, resulting in the increased temperature of the processor. In this paper, the floorplan methods which change the forms of vertical placement of the core and the level-2 cache are analyzed to solve the thermal problems in 3D multi-core processors. According to the experimental results, it is an effective way to reduce the temperature in the processor that the core and the level-2 cache are stacked adjacently. Compared to the floorplan where cores are stacked adjacently to each other, the floorplan where the core is stacked adjacently to the level-2 cache can reduce the temperature by 22% in the case of 4-layers, and by 13% in the case of 2-layers.

Performance Analysis of RS codes for Low Power Wireless Sensor Networks (저전력 무선 센서 네트워크를 위한 RS 코드의 성능 분석)

  • Jung, Kyung-Kwon;Choi, Woo-Seung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.83-90
    • /
    • 2010
  • In wireless sensor networks, the data transmitted from the sensor nodes are susceptible to corruption by errors which caused of noisy channels and other factors. In view of the severe energy constraint in Sensor Networks, it is important to use the error control scheme of the energy efficiently. In this paper, we presented RS (Reed-Solomon) codes in terms of their BER performance and power consumption. RS codes work by adding extra redundancy to the data. The encoded data can be stored or transmitted. It could have errors introduced, when the encoded data is recovered. The added redundancy allows a decoder to detect which parts of the received data is corrupted, and corrects them. The number of errors which are able to be corrected by RS code can determine by added redundancy. The results of experiment validate the performance of proposed method to provide high degree of reliability in low-power communication. We could predict the lifetime of RS codes which transmitted at 32 byte a 1 minutes. RS(15, 13), RS(31, 27), RS(63, 57), RS(127,115), and RS(255,239) can keep the days of 173.7, 169.1, 163.9, 150.7, and 149.7 respectively. The evaluation based on packet reception ratio (PRR) indicates that the RS(255,239) extends a sensor node's communication range by up about 3 miters.

An Application-Specific and Adaptive Power Management Technique for Portable Systems (휴대장치를 위한 응용프로그램 특성에 따른 적응형 전력관리 기법)

  • Egger, Bernhard;Lee, Jae-Jin;Shin, Heon-Shik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.8
    • /
    • pp.367-376
    • /
    • 2007
  • In this paper, we introduce an application-specific and adaptive power management technique for portable systems that support dynamic voltage scaling (DVS). We exploit both the idle time of multitasking systems running soft real-time tasks as well as memory- or CPU-bound code regions. Detailed power and execution time profiles guide an adaptive power manager (APM) that is linked to the operating system. A post-pass optimizer marks candidate regions for DVS by inserting calls to the APM. At runtime, the APM monitors the CPU's performance counters to dynamically determine the affinity of the each marked region. for each region, the APM computes the optimal voltage and frequency setting in terms of energy consumption and switches the CPU to that setting during the execution of the region. Idle time is exploited by monitoring system idle time and switching to the energy-wise most economical setting without prolonging execution. We show that our method is most effective for periodic workloads such as video or audio decoding. We have implemented our method in a multitasking operating system (Microsoft Windows CE) running on an Intel XScale-processor. We achieved up to 9% of total system power savings over the standard power management policy that puts the CPU in a low Power mode during idle periods.

Atmospheric Pressure Plasma Treatment of Aqueous Bisphenol A Solution (비스페놀 A 수용액의 대기압 플라즈마 처리)

  • Jo, Jin-Oh;Choi, Kyeong Yun;Gim, Suji;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.26 no.3
    • /
    • pp.311-318
    • /
    • 2015
  • This work investigated the plasma treatment of aqueous bisphenol A (BPA) solution and mineralization pathways. For the effective contact between plasmatic gas and aqueous BPA solution, the plasma was created inside a porous ceramic tube, which was uniformly dispersed into the aqueous solution through micro-pores of the ceramic tube. Effects of the gas flow rate, applied voltage and treatment time on the decomposition of BPA were examined, and analyses using ultraviolet (UV) spectroscopy, ion chromatography and gas chromatography-mass spectrometry were also performed to elucidate mineralization mechanisms. The appropriate gas flow rate was around $1.0L\;min^{-1}$; when the gas flow rate was too high or too low, the BPA decomposition performance at a given electric power decreased. The increase in the voltage improves the BPA decomposition due to the increased electric power, but the energy required to remove BPA was similar, regardless of the voltage. Under the condition of $1.0L\;min^{-1}$ and 20.8 kV, BPA at an initial concentration of $10L\;min^{-1}$ (volume : 1 L) was successfully treated within 30 min. The intermediates produced by the attack of ozone and hydroxyl radicals on BPA were further oxidized to stable compounds such as acetate, formate and oxalate.

Electrorefining Behavior of Zirconium Scrap with Multiple Cathode in Fluoride-Based Molten Salt (불화물계 용융염을 이용한 지르코늄 스크랩의 다중전극 전해정련 거동)

  • Park, Dong Jae;Kim, Seung Hyun;Park, Kyoung Tae;Mun, Jong Han;Lee, Hyuk Hee;Lee, Jong Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • The production of nuclear fuel cladding tube is expected to increase with the nuclear power plant expansion. Zirconium(Zr) scrap that is generated during manufacturing is also expected to increase. Zr electrorefining experiment was carried out in the fluoride salt of LiF-KF-ZrF4 using multiple electrode for scale up and improving throughput Zr electrorefiner develop-ment. The Zr reduction peak observed at-0.8 V(vs.Ni). Polarization behavior showed that the amount of applied current increases because of decreasing cell resistance as the number of cathode increases. Experimental results showed the highest recovery rate about 98% at lowest current density of 25.64 mA/cm2 using 6 electrodes. XRD and TG analysis result show that pure Zr was recovered 99.92% and ICP analysis shows that lower impurity content than conventional impurity content of the Anode(97.8%). Electrorefining consumes energy about 7.15 kWh/kg less than 39.7% compared to the Kroll process using 6 electrode width of 20 mm and height of 65 mm. Because of increasing cell efficiency and recovery rate, using multiple cathode is determined as an efficient technique for scale up electrorefining Zr scrap.

Performance Analysis on The Reactive Repeater Jamming Techniques Against an RCIED Using Mobile Devices (모바일 단말을 이용한 RCIED에 대한 repeater 방식의 반응 재밍 기법 성능 분석)

  • Kim, Yo-Han;Kim, Dong-Gyu;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.55-63
    • /
    • 2015
  • Recently, terroristic threats using a radio controlled improvised explosive device (RCIED) that is remotely controlled and exploded have been increased around the world. In order to prevent the explosion of an RCIED, jamming techniques that interrupt an RCIED receiver can be used, so that the receiver can not demodulate the trigger code. Conventional jamming technique is a type of active barrage jamming that always emits the noise jamming signal for all the frequency band. However, it needs large power consumption and thus is limited in operation time for a vehicle. In order to overcome the shortage of the active barrage jamming, reactive jamming technique has drawn attention. In reactive jamming, all the frequency band is firstly scanned, and then if any trigger signal exists, one emits the jamming signal to the corresponding frequency band. Therefore, the reactive jamming is superior to the active barrage jamming in terms of power efficiency. However, a reactive jammer emits a jamming signal only after the trigger signal is intercepted, which means that the jamming signal may be late for interrupting an RCIED receiver. In this sense, it is needed to evaluate a delay in an RCIED receiver. To achieve this, we analyze the reaction time and present the simulation result for jamming performance of reactive jamming against an RCIED using mobile devices.

A Study on Electrodewatering Filter Press Technology for Improvement of Dewarterability of Waterworks Sludge (정수슬러지 탈수효율 향상을 위한 전기필터프레스탈수에 관한 연구)

  • Lee, Jung-Eun;Lee, Jae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1009-1015
    • /
    • 2006
  • The elcetrodewatering filter press(EDFP) which had anode and cathod plates to be set between filter plates was built for reducing the waterworks sludge and improving performance of dewatering equipment. Several tests to compare the dewaterability with conventional mechanical filter press dewatering(MDEP) and EDFP was conducted through this equipment. As test results, filtration amount discharged from EDFP measured 43.2 kg which increased against MDFP, and cake weight measured 4 kg which was two times against MDFP. The water content of dewatered cake from EDFP was 55wt% and dewatering velocity was 2.3 $kg/m^2{\cdot}cycle$. This water content decrease 20% and dewatering velocity increased 30% with compare to the MDFP. That is to say, EDFP constructed from electrodewatering mechanism increase filtrate discharging amount, which make dewatering velocity increase and produce the low water content dewatered cake against MDFP. Energy consumption of EDFP is analysed to 400 kwh/DS ton. The results to analysis the economical aspect considering the power consumption and the handling cost decline as sludge volume reduction due to producing the low water content cake showed that expenses to handle sludge of 1 ton by dry solid base cut down on 20,000 won. If considering several test aspects, it was analysed that EDFP was excellent in the side of performance as well as economical suitability.

Analysis of Input/Output Transfer Characteristic to Transmit Modulated Signals through a Dynamic Frequency Divider (동적 주파수 분할기의 변조신호 전송 조건을 위한 입출력 전달 특성 분석과 설계에 대한 연구)

  • Ryu, Sungheon;Park, Youngcheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.170-175
    • /
    • 2016
  • In order to transmit baseband signals through frequency dividing devices, we studied the transfer function of the device in the term of the baseband signal distortion. From the analysis, it is shown that the magnitude of the envelope signal is related to the mixer gain and the insertion loss of the low pass filter whilst the phase is the additional function with the 1/2 of the phase delay. For the purpose of the verification of the study, we designed a dynamic frequency divider at 1,400 MHz. The operating frequency range of the device is closely related to the conversion gain of mixers and the amplitude of input signal, and becomes wide as the conversion gain of mixers increases. The designed frequency divider operates between 0.9 GHz and 3.2 GHz, for -14.5 dBm input power. The circuit shows 20 mW power dissipation at $V_{DD}=2.5V$, and the simulation result shows that an amplitude modulated signal at 1,400 MHz with the modulation index of 0.9 was successfully downconverted to 700 MHz.