• Title/Summary/Keyword: 센서 진단

Search Result 846, Processing Time 0.026 seconds

m-Health System for Processing of Clinical Biosignals based Android Platform (안드로이드 플랫폼 기반의 임상 바이오신호 처리를 위한 모바일 헬스 시스템)

  • Seo, Jung-Hee;Park, Hung-Bog
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.7
    • /
    • pp.97-106
    • /
    • 2012
  • Management of biosignal data in mobile devices causes many problems in real-time transmission of large volume of multimedia data or storage devices. Therefore, this research paper intends to suggest an m-Health system, a clinical data processing system using mobile in order to provide quick medical service. This system deployed health system on IP network, compounded outputs from many bio sensing in remote sites and performed integrated data processing electronically on various bio sensors. The m-health system measures and monitors various biosignals and sends them to data servers of remote hospitals. It is an Android-based mobile application which patients and their family and medical staff can use anywhere anytime. Medical staff access patient data from hospital data servers and provide feedback on medical diagnosis and prescription to patients or users. Video stream for patient monitoring uses a scalable transcoding technique to decides data size appropriate for network traffic and sends video stream, remarkably reducing loads of mobile systems and networks.

A Dynamic Duty Cycle Adjustment Mechanism for Reduced Latency in Industrial Plants (플랜트 시설에서 지연시간 감소를 위한 동적 듀티사이클 조절 기법)

  • Jung, Jinman;Yoon, Jisup;Yun, Young-Sun;So, Sunsup;Eun, Seongbae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.193-198
    • /
    • 2016
  • For environmental monitoring and risk identification of industrial plants, several monitoring systems using Wireless Sensor Networks (WSNs) have been developed. In this paper, we propose a dynamic duty cycle adjustment mechanism for reduced latency in industrial plants. The proposed method adjusts the duty cycle among predefined risk groups depending on the urgency of sensed data values. To demonstrate its efficacy, we analyze the expected transmission latency model and then discuss the characteristics in detail. We show that the proposed dynamic duty cycle mechanism is a more effective than a periodic mechanism by analyzing the expected latency of them in industrial plants where there are various types of sensory data with different levels of reliability.

신경회로의 로보트 및 자동화 응용

  • 오세영
    • The Magazine of the IEIE
    • /
    • v.18 no.10
    • /
    • pp.29-38
    • /
    • 1991
  • 제6세대 컴퓨터로 불리는 신경컴퓨터는 학습과 병렬처리에 의해 인간의 두뇌 기능을 모방한다. 인간의 두뇌는 시각 인식, 음성인식, 촉각 감지등 패턴 인식뿐 아니라 인간의 복잡한 신체구조를 시각, 촉각 같은 감각기관의 도움을 얻어 움직이는 중요한 역할도 한다. 바로 이 모터제어(motor control)역시 신경회로가 담당하기 때문에 이를 기계적 신체에 해당하는 로봇 또는 광범위하게 기계, 비행기, 산업공정에 응용하는 것은 매우 자연스럽게 보인다. 이처럼 신경회로가 제어에 응용되는 것을 신경제어(neurocontrol)라 하고 이를 이용한 기계를 지능기계(intelligent machinery)라 한다. 지능기계는 기본적으로 인간처럼 경험축적, 학습, 불확실한 환경에서의 적응, 자기진단 등의 장점을 가지고 있다. 신경회로의 지극히 광범위한 응용분야중 신경제어는 가장 먼저 실현될 가능성이 높다. 실제로 로봇나 공정제어(process control)처럼 복잡한 비선형 시스템의 제어는 다량의 센서 정보에 기초한 실시한 제어를 필수로 하며 이는 신경회로를 사용함으로써 가장 효율적, 경제적으로 구현할 수 있다. 실제로 신경제어는 전세계적으로 이미 시스템 제어에 응용되어 좋은 결과를 내고 있다. 신경회로의 로봇나 자동화 응용은 학술적인 측면에서는 복잡한 비선형 시스템의 지능제어(intelligent control)문제에 대한 신선한 해결책을 마련해줄 뿐 아니라 산업자동화라는 막대한 시장을 뒤로 하고 있어 이론에서 실제에 걸쳐 가장 광범위한 파급효과를 가지는 최첨단 기술로 보여진다. 고부가가치 상품을 통한 국제경쟁력 제고의 차원에서도 정부, 기업 등의 과감한 연구 개발투자가 선행되어야 한다. 특히 이 분야의 연구는 선진국도 최근에 시작한 점으로 보아 정부, 기업이 이에 대한 연구개발 투자를 현명하게 할 경우에 세계적 기술 경쟁력도 확보할 수 있을 것이다. 본 해설에서는 로봇 및 시스템 제어에 관한 기초 이론과 신경회로 적용기술을 소개하고 기존방법과 비교했을 때의 우월성, 전세계적인 응용연구, 국내외 연구개발 현황, 상업화 가능성, 산업계 응용례, 기술상의 문제점, 향후 전망 등을 다루기로 한다.

  • PDF

A Study on the Implementation of the Healthcare Device and the Telemedicine System using ZigBee (ZigBee를 활용한 헬스케어 장치 및 원격 의료 서비스 시스템 구현에 관한 연구)

  • Cho, Sung-Min;Kang, Sung-In;Kim, Gwan-Hyung;Choi, Sung-Wook;Kwon, Oh-Hyun;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.469-472
    • /
    • 2007
  • The telemedicine system provide an efficient means to monitor the status of health and measure bio-information even though the limitation of distance and time. The telemedicine system can be divided into two categories. The first one is Remote Support Service which can monitor the patient including home environments and give those diagnosis information to medical office. and the other one is Alarm Service that can be used for tile emergency status. For the convenience of the patient we will design and implement portable healthcare device and the telemedicine system under the wireless ZigBee network environments.

  • PDF

Data Storage and Security Model for Mobile Healthcare Service based on IoT (IoT 기반의 모바일 헬스케어 서비스를 위한 데이터 저장 및 보호 모델)

  • Jeong, Yoon-Su
    • Journal of Digital Convergence
    • /
    • v.15 no.3
    • /
    • pp.187-193
    • /
    • 2017
  • Objects Internet-based healthcare services provide healthcare and healthcare services, including measurement of user's vital signs, diagnosis and prevention of diseases, through a variety of object internet devices. However, there is a problem that new security vulnerability can occur when inter-working with the security weakness of each element technology because the internet service based on the object Internet provides a service by integrating various element technologies. In this paper, we propose a user privacy protection model that can securely process user's healthcare information from a third party when delivering healthcare information of users using wearable equipment based on IoT in a mobile environment to a server. The proposed model provides attribute values for each healthcare sensor information so that the user can safely handle, store, and store the healthcare information, thereby managing the privacy of the user in a hierarchical manner. As a result of the performance evaluation, the throughput of IoT device is improved by 10.5% on average and the server overhead is 9.9% lower than that of the existing model.

Software Architecture of a Wearable Device to Measure User's Vital Signal Depending on the Behavior Recognition (행동 인지에 따라 사용자 생체 신호를 측정하는 웨어러블 디바이스 소프트웨어 구조)

  • Choi, Dong-jin;Kang, Soon-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.3
    • /
    • pp.347-358
    • /
    • 2016
  • The paper presents a software architecture for a wearable device to measure vital signs with the real-time user's behavior recognition. Taking vital signs with a wearable device help user measuring health state related to their behavior because a wearable device is worn in daily life. Especially, when the user is running or sleeping, oxygen saturation and heart rate are used to diagnose a respiratory problems. However, in measuring vital signs, continuosly measuring like the conventional method is not reasonable because motion artifact could decrease the accuracy of vital signs. And in order to fix the distortion, a complex algorithm is not appropriate because of the limited resources of the wearable device. In this paper, we proposed the software architecture for wearable device using a simple filter and the acceleration sensor to recognize the user's behavior and measure accurate vital signs with the behavior state.

신경컴퓨터(Neural Network)을 이용한 로보트 제어

  • 오세영
    • Information and Communications Magazine
    • /
    • v.9 no.11
    • /
    • pp.70-79
    • /
    • 1992
  • 제6세대 컴퓨터로 불리는 신경컴퓨터는 학습과 병렬처리에 의해 인간의 두뇌 기능을 모방한다. 인간의 두뇌는 시각인식, 음성인식, 촉각감지 등 패턴인식뿐 아니라 인간의 복잡한 신체구조를 시각, 촉각 같은 감각기관의 도움을 얻어 움직이는 중요한 역할도 한다. 바로 이 모터제어(motor control) 역시 신경회로가 담당하기 때문에 이를 기계적 신체에 해당하는 로보트 또는 광범위하게 기계, 비행기, 산업공정에 응용하는 것은 매우 자연스럽게 보인다. 이처럼 신경회로가 제어에 응용되는 것을 신경제어 (neurocontrol)라 하고 이를 이용한 기계를 지능기계(intelligent machinery)라 한다. 지능기계는 기본적으로 인간처럼 경험축적 학습 불확실한 환경에서의 적응 자기진단 등의 장점을 가지고 있다. 신경회로의 지극히 광범위한 응용분야중 신경제어는 가장 먼저 실현될 가능성이 높다. 실제로 로보트나 공정제어(process control)처럼 복잡한 비선형 시스템의 제어는 다량의 센서 정보에 기초한 실시간 제어를 필수로 하며 이는 신경회로를 사용함으로써 가장 효율적, 경제적으로 구현할 수 있다. 실제로 신경제어는 전세계적으로 이미 시스템 제어에 응용되어 좋은 결과를 내고 있다. 신경회로의 로보트나 자동화 응용은 학술적인 측면에서는 복잡한 비선형 시스템의 지능제어 (intelligent control)문제에 대한 신선한 해결책을 마련해줄 뿐 아니라 산업자동화라는 막대한 시장을 뒤로 하고 있어 이론에서 실제에 걸쳐 가장 광범위한 파급효과를 가지는 최첨단 기술로 보여진다. 고부가가치 상품을 통한 국제 경쟁력 제고의 차원에서도 정부, 기업 등의 과감한 연구 개발투자가 선행되어야 한다. 특히 이 분야의 연구는 선진국도 최근에 시작한 점으로 보아 정부, 기업이 이에 대한 연구 개발투자를 현명하게 할 경우에 세계적 기술 경쟁력도 확보할 수 있을 것이다. 본 해설에서는 로보트 및 시스템 제어에 관한 기초 이론을 설명하고 신경회로 적용기술을 소개하고 기존 방법과 비교 했을 때의 우월성, 전세계적인 응용연구, 국내외 연구개발 현황, 상업화 가능성, 산업계 응용례, 기술상의 문제점, 향후 전망 등을 다루기로 한다.

  • PDF

Toxicogenomic Analysis of Bacteria and Medaka Fish in Response to Environmental Toxic Chemicals

  • Gu Man-Bock
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2006.02a
    • /
    • pp.116-123
    • /
    • 2006
  • 생물체의 cDNA를 유리기판위에 고밀도로 첨착 시킨 유전자 칩과 정량적인 방법으로 개별 유전자 발현을 진단 가능한 Real- time PCR (실시간 고분자중합연쇄반응 기술) 기법은 첨단 의학분야와 신약개발 및 독성유전체 연구분야에 활발히 도입되고 있는 기술이다. 본 발표의 첫 번째 부분에서는 유전자칩 에서 얻어진 유전자 발현패턴분석에 기반한 바이오마커 선정 및 real time PCR에 의한 확증 관련 기술 과 유전자칩에서 얻어지는 수많은 데이터를 재정렬 및 다양한 분석기법과 display기술을 활용하여 광범위한 화학물질에 대한 독성효과 분석을 가능하게 해주며, 특정 독성물질에 대한 관련유전자 그룹 발견 및 독성영향에 따른 분류방법에 관한 결과를 발표할 것이다. 또한 바이오마커 활용의 하나로 박테리아세포 기반 바이오센서 제작및 세포칩 개발등에 대한 결과도 추가될 것이다. 두 번째 부분에서는 non-model organism(유전체정보가 확보되지 않은 생물체)인 송사리를 이용하여 새로운 2K 유전자칩을 개발하고, 여기서 각종 화학물질에 대하여 얻어진 수많은 유전자칩 분석 데이타를 활용하여 각각의 화학물질이 보여주는 독성효과를 매우 효과적이고 쉽게 이해할 수 있는 display기술을 개발, 적용함으로써 유전자칩 발현에 기반한 화학물질 독성 screening 및 specificity discrimination을 가능케 하는 예가 발표될 것이다. 이 연구에서 개발한 송사리 유전자칩은 간조직의 RNA를 직접 cDNA화 하는 방식을 취하고 있어 전체 송사리의 유전정보를 필요로 하지 않아 비용 및 효율에서 전체 송사리의 유전정보를 얻는 비용과 노력을 취하지 않고 간에서 발생하는 독성학적 영향 및 유전자의 발현정도를 정밀하고 효율적인 방법으로 얻어 낸다. 현재 2000여개의 cDNA유전자중 50%이상의 유전자가 17베타에스트라디올, 페놀, 노닐페놀, 비스페놀, 감마레이조사, 잔류약품중 이보프란, 다이클로펜악, 농약중의 파라???R, 돌연변이 유발물질 중의 이티비알, 금속류중의 카드뮴을 통해 발현양상과 특정 캐미칼별 발현 특이성이 조사되었고, 이들 유전자는 염기서열 분석을 통해 염기서열이 분석되었으며, 미국 NCBI의 유전자 은행과의 비교를 통해 일부유전자는 새로운 유전자로 밝혀지고 있다. 또한 이 발표에서는 소염진통제계열 의약품인 dichlofenac 이 송사리의 각종 조직에 미치는 독성영향을 Real-time PCR을 이용하여 대표적 스트레스 유전자의 발현에 미치는 영향에 대한 분석 예가 발표될 것이다.

  • PDF

Signal-based Fault Diagnosis Algorithm of Control Surfaces of Small Fixed-wing Aircraft (소형 고정익기의 신호기반 조종면 고장진단 알고리즘)

  • Kim, Jihwan;Goo, Yunsung;Lee, Hyeongcheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1040-1047
    • /
    • 2012
  • This paper presents a fault diagnosis algorithm of control surfaces of small fixed-wing aircraft to reduce maintenance cost or to improve repair efficiency by estimation of fault occurrence or part replacement periods. The proposed fault diagnosis algorithm consists of ANPSD (Averaged Normalized Power Spectral Density), PCA (Principle Component Analysis), and GC (Geometric Classifier). ANPSD is used for frequency-domain vibration testing. PCA has advantage to extract compressed information from ANPSD. GC has good properties to minimize errors of the fault detection and isolation. The algorithm was verified by the accelerometer measurements of the scaled normal and faulty ailerons and the test results show that the algorithm is suitable for the detection and isolation of the control surface faults. This paper also proposes solutions for some kind of implementation problems.

Magnetic Noise Reduction in MCG Using Spatial Filters (공간 필터를 이용한 심자도 신호에서의 자기잡음 제거)

  • Lee, Hana;Kim, Ki-Wang;Lee, Soo-Yeol;Cho, Min-Hyung;Heo, Young
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.287-292
    • /
    • 2003
  • Even though MCG has many advantages over ECG, MCG signa)s are easily corrupted by external magnetic noises Since multi-channel MCG signals are recorded simultaneously at many spatial positions, it is effective to apply spatial fitters as well as the conventional temporal filters to remove external magnetic noises. The spatial filters can be designed by utilizing the fact that the noise signals caused by external noise sources are more spatially correlated than the original MCG signals. In this paper, we introduce a spatial filtering method for the noise reduction in MCG based on the principal component analysis. Healthy volunteer study results obtained with a 61-channel MCG system are presented.