Abstract
The paper presents a software architecture for a wearable device to measure vital signs with the real-time user's behavior recognition. Taking vital signs with a wearable device help user measuring health state related to their behavior because a wearable device is worn in daily life. Especially, when the user is running or sleeping, oxygen saturation and heart rate are used to diagnose a respiratory problems. However, in measuring vital signs, continuosly measuring like the conventional method is not reasonable because motion artifact could decrease the accuracy of vital signs. And in order to fix the distortion, a complex algorithm is not appropriate because of the limited resources of the wearable device. In this paper, we proposed the software architecture for wearable device using a simple filter and the acceleration sensor to recognize the user's behavior and measure accurate vital signs with the behavior state.
Keywords
wearable device; accelerometer; motion detection; heart rate; oxygen saturation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 H. Al Haddad, et al., "Effect of acute hypoxia on post-exercise parasympathetic reactivation in healthy men," Front. Physiol., vol. 3, Jul. 2012.
2 N. Ravi, N. Dandekar, P. Mysore, and M. L. Littman, "Activity recognition from accelerometer data," AAAI, vol. 5, pp. 1541-1546, Jul. 2005.
3 X. Long, B. Yin, and R. M. Aarts, "Single-accelerometer-based daily physical activity classification," Eng. Med. Biology Soc., pp. 6107-6110, Sept. 2009.
4 A. M. Khan, et al., "A triaxial accelerometerbased physical-activity recognition via augmented-signal features and a hierarchical recognizer," Inf. Technol. in Biomed., vol. 14, no. 5, pp. 1166-1172, Jun. 2010.   DOI
5 S. Seyedtabaii and L. Seyedtabaii, "Kalman filter based adaptive reduction of motion artifact from photoplethysmographic signal," World Academy Sci. Eng. Technol., vol. 37, pp. 173-176, 2008.
6 H. Lee, et al., "The periodic moving average filter for removing motion artifacts from PPG signals," Int. J. Control Automation and Syst., vol. 5, no. 6, pp. 701-706, Dec. 2007.
7 R. Yousefi, et al., "A motion-tolerant adaptive algorithm for wearable photoplethysmographic biosensors," IEEE J. Biomedical and Health Informatics, vol. 18, no. 2, pp. 670-681, May 2013.   DOI
8 A. R. Relente and L. G. Sison, "Characterization and adaptive filtering of motion artifacts in pulse oximetry using accelerometers," Eng. Med. Biology, vol. 2, pp. 1769-1770, Oct. 2002.
9 N. S. Schenkel, et al., "Oxygen saturation during daily activities in chronic obstructive pulmonary disease," Eur. Respiratory J., vol. 9, no. 12, pp. 2584-2589, Dec. 1996.   DOI
10 A. Romem, et al., "Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals," J. JCSM, vol. 10, no. 3, pp. 285-290, Mar. 2014.
11 C. C. Rezk, et al., "Post-resistance exercise hypotension, hemodynamics, and heart rate variability: influence of exercise intensity," Eur. J. Appl. Physiol. 98, pp. 105-112, Sept. 2006.   DOI
12 B. S. Kim and K. Y. Sun, "Motion artifact reduction in photoplethysmography using independent component analysis," IEEE Trans. Biomed. Eng., vol. 53, no. 3, pp. 566-568, Mar. 2006.   DOI
13 L. B. Wood, and H. H. Asada, "Low variance adaptive filter for cancelling motion artifact in wearable photoplethysmogram sensor signals," 29th Annu. Int. Conf. IEEE, Eng. Med. and Biol. Soc., pp. 652-655, Aug. 2007.
14 H. H. Asada, H.-H. Jiang, and P. Gibbs, "Active noise cancellation using MEMS accelerometers for motion-tolerant wearable bio-sensors," 26th Annu. Int. Conf. IEEE, Eng. Med. Biol. Soc., vol. 1, pp. 2157-2160, Sept. 2004.
15 W. Zong, et al., "An open-source algorithm to detect onset of arterial blood pressure pulses," Computers in Cardiology, pp. 259-262, Sept. 2003.