• Title/Summary/Keyword: 성능 평가 기준

Search Result 2,424, Processing Time 0.032 seconds

Performance Evaluation Method for Facility Inspection and Diagnostic Technologies (첨단기술을 활용한 시설물 점검 및 진단 기술 검·인증을 위한 성능평가 방법론)

  • Lee, Young-Ho;Bae, Sung-Jae;Jung, Wook;Cho, Jae-Yong;Hong, Sung-Ho;Nam, Woo-Suk;Kim, Young-Min;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.178-191
    • /
    • 2020
  • Purpose: This paper proposes a performance evaluation method for state-of-the-art facility inspection/diagnostic equipment through a trend survey of equipment and standardization systems of US, Japan, and Korea. This paper also suggests the priority of developing a performance evaluation method through expert interviews and surveys. Method: In this study, report for the last 5 years of FMS, state-of-the-art equipment of facility maintenance companies/safety diagnosis specialist agencies and papers/research reports/patents of NTIS were analyzed to identify recent trends of facility inspection/diagnostic equipment usages. standardization system of US, Japan, and Korea were analyzed to figure out a suitable form of a performance evaluation method for the domestic situation. And expert interview and survey were conducted to identify the priority of developing a performance evaluation method. Result: The performance evaluation method must be developed by the shape that only evaluates performance, regardless of types of equipment, on inspection item level for creative technology development. The priority of developing the performance evaluation method was identified as crack detection of concrete for durability evaluation and displacement/deformation/fatigue detection of concrete and steel for stability evaluation. Conclusion: The performance evaluation method will be developed firstly for the crack detection of concrete for durability evaluation and displacement/deformation/fatigue detection of concrete/steel for stability evaluation. In order to promote creative technology development, the performance evaluation method should be developed in a form that provides standardized specimens or testbeds and can be applied regardless of types of technologies.

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

A Study on the Development of a Fire Extinguishing Agent Leakage Monitoring Module and its Performance Assessment (소화약제 누기 감시장치의 모듈개발 및 성능검증에 관한 연구)

  • Son, Bong-Sei;Hong, Sung-Ho;Go, A-Ra
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.43-48
    • /
    • 2016
  • One of the main problems with gaseous fire extinguishers is the decrease in fire suppression capability due to the leakage of the fire extinguishing agents, either naturally or caused by obsolete equipment. Therefore, in this study, a real-time detector module for monitoring pressure leakages was developed and an assessment on its performance was carried out. Currently, there are no domestic or global standards for testing pressure leakage detection systems. Therefore, similar global standards, such as ISO 7240 and FM 1421, and the domestic law on "Receiver type-approval and technical standards for product inspection" were used as a reference for assessing the performance of the newly developed module. Its basic performance was assessed by applying compressed air to the module, and, as a result, the minimum working pressure was identified as 0.3 bar. Its environmental qualification was carried out to confirm the proper functioning of the module in different climates and the module was confirmed to function properly at both high ($50^{\circ}C$) and low ($-10^{\circ}C$) temperatures.

A Study on Total Fire Risk Assessment of Wallpapers (벽지의 종합적 화재 위험성 평가에 관한 연구)

  • 박미라;김광일;김태구
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.33-39
    • /
    • 2003
  • The purpose of this study is to evaluate flame retardant performance, thermal stability and toxicity of combustion gases for some commercial wallpapers. ID evaluate flame retardant performance 45 degree combustion experiment method was used and thermal stability was evaluated using DSC and TGA apparatus (OSC-50/Shimadzu, TGA2050/TA Instruments Inc) . Concentrations of CO, $CO_2$, HCN and HCI were measured with (GASTEC/Japan, MSA400 Gas Monitor/Infitron Inc) and toxicity indices using NIST N-Gas Model were applied to evaluate the toxicity of combustion gases. The evaluation produced the following results : First, paper cork and PVC wallpaper treated with flame retardants were found to be suitable for flame retardant performance standards. Second, paper, cork and PVC wallpaper non-treated with flame retardants were shown to be relatively more hazardous because they had greater calorific values and a faster decomposition time than the flame retardant treated wallpapers. Third, the toxicity indices of non-treated wallpapers were found to be higher than those of treated wallpapers, and the toxicity index of PVC wallpapers was higher than those of paper and cork wallpapers.

Three Dimensional Electric Field Analysis for 3-phase encapsulated Arrangement of GIS (3차원 전계해석법을 통한 초고압 GIS 상배치 구조에 관한 절연성능평가)

  • Yoon, J.H.;Jeong, S.Y.;Choi, J.W.;Kang, S.M.;Oh, I.S.;Im, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.60-62
    • /
    • 2003
  • 본 연구는, 초고압 GIS(Gas Insulated Switchgear)용 GCB(Gas Circuit Breaker)의 3상 배치구조를 설계 하기 위한 상간, 대지간의 절연성능을 평가하였다. 피임펄스 전압과 상용주파 전압인가시 상간, 대지간의 절연설계 기준과 비교하여 절연설계 안전율을 고려하여 설계에 적용하였다. 수치적 전계 해석법으로 3차원 전계 해석법과 2차원 축대칭 전계 해석법을 통해 전계 강도를 비교하였으며 3차원 전계 해석법으로는 경계 요소법(Boundary Element Method)을 사용하는 상용프로그램인 coulomb을 사용하였으며, 2차원 전계 해석법으로는 유한요소법(Finite Element Method)을 사용하는 Maxwell을 통해 절연성능 평가를 하였다. 마지막으로, 전계 해석을 통해 절연설계 기준에 적합한 상배치 구조 설계를 하였다.

  • PDF

전력품질향상기기의 성능평가방안

  • Kim, Jae-Eon;Min, Jun-Gi;Cho, Sung-Hyun;Lee, Dong-Gu;Kim, Chang-Soon;Kwon, Hoon
    • 전기의세계
    • /
    • v.53 no.7
    • /
    • pp.31-35
    • /
    • 2004
  • 본 고에서는 현재 개발 및 필드테스트되고 있는 전력품질 보상기기인 STATCOM(Static Compensator), DVR(Dynamic Voltage Restorer), 고속전력절체스위치 SSTS(Solid State Transfer Switch)들이 국내 22.9kV급 배전계통에 도입되어 운용될 경우, 배전계통의 전력품질상의 외란, 즉 voltage sag, voltage swell, interruption등에 대해서도 부하기기가 문제없이 잘 동작할 수 있어야 하는 전력품질향상기기의 성능(전력품질향상기준)에 대한 평가방법 에 대하여 기술하고자 한다. 먼저, 전력품질향상기기인 DVR, D-STATCOM, SSTS들이 만족해야할 전력품질향상기준을 국내 전력 품질 실태를 고려하여 제시하고, 또한, 이들 전력품질향상기기에 대한 국내 배전계통적용에 적합한 성능평가방안을 제안/소개하기로 한다. (중략)

  • PDF

Pilot Application of Fire Barrier Penetration Seal Evaluation in Nuclear Power Plant (원자력발전소 방화벽 관통부 성능평가 시범 적용)

  • Park, Jun-Hyun
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.98-104
    • /
    • 2006
  • The Fire Protection Regulatory documents require the fire-resistive rating of fire barrier penetration seals be same as that of fire barriers. Pilot application of penetration seal evaluation for K nuclear plant, built before penetration seal requirements were made, was done. In this evaluation, visual inspection and estimating fire rating by comparing installed configuration with tested configuration of penetration seals, called bounding approach method, were applied. Further improvements for retrofit and maintenance are recommended with penetration seal evaluation results also. The practical use of the methodology adopted in this study and the evaluation result of K nuclear plant will be anticipated for other plant's penetration seal evaluation.

A study of economic standards on selected water supply pipes each house landing district (택지지구별 선정 상수관에 대한 경제성 기준 검토)

  • Kim, Young-Jin;Sohn, Kyung-Jung;Park, Hyo-Sang;Jin, Kyu-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.656-661
    • /
    • 2009
  • 상수도시설은 준공후 관련지자체에 이관 관리하는 시설로서 사용관종이 현재 다양하게 생산 보급되고 있어 관종 선정시 다각적인 측면에서 검토하여 채택하여야 한다. 최근 한국토지공사에서 사용하고 있는 상수도 관종은 대부분 택지개발계획 등 인허가 당시부터 관리주체인 지방자치단체 등과의 협의과정을 거쳐 선정되는 경우가 많아 자재선택에 한계성이 있다. 이를 극복하기 위해서는 자재 성능에 대한 공사내 명확한 기준이 제시되어야 한다. 상수관종을 선정하기 위한 가장 중요한 요소는 경제성으로 판단되는데, 관종의 경제성은 시공비와 자재비를 포함한 단순 공사비에만 국한되는 것이 아니라 유지관리비용을 포함한 생애주기비용(LCC: Life Cycle Cost)을 평가하여야 한다. 따라서 본 연구에서는 한국토지공사에서 택지지구 조성을 위해 사용한 배수관.급수관용 상수관종에 대한 경제성 평가기준을 제시하였고, 평가기준에 따라 각각의 택지지구 조성사례별로 종합적인 경제성 평가를 수행하였다. 보다 풍부한 자료를 바탕으로 객관적인 경제성평가 기준을 수립하기 위한 전(前)과정으로 이해되길 바라며, 설계시부터 객관적인 평가기준을 통해 합리적인 상수관을 선정하여 지금까지의 상수관종 자재선택의 한계를 최소한으로 축소하고자 하는데 가장 큰 목표를 가지고 있다.

  • PDF

Fuzzy-based Decision Support Model for Determining Preventive Maintenance Works Order (퍼지 집합을 활용한 건물 사전 보수작업 대상 선정 지원모델)

  • Ko, Taewoo;Park, Moonseo;Lee, Hyun-Soo;Kim, Hyunsoo;Kim, Sooyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.51-61
    • /
    • 2014
  • Preventive maintenance of buildings has increased the importance of interest in that it is able to maintain the performance building has and to prevent a problem occurred in future. For improved preventive maintenance work, it should be performed to select works order clearly and preceded the accurate measurement for the state of works order. when measuring the conditions, measurement of the state of work order considering the various criteria is more effective than to measure by only criterion. But, there are something hard to evaluate exactly between the criteria because of decision-maker's subjective judgments. To solve these problems, this research proposes decision making support model to determine preventive maintenance works order using Fuzzy-sets. By using Fuzzy-sets when measuring state of work objects, it can be reduced vagueness of judgments by decision-makers. This model can be used as a tool for objective evaluation of preventive maintenance work orders and offer the guideline to perform decision-making.