• Title/Summary/Keyword: 성능감소

Search Result 7,565, Processing Time 0.038 seconds

Performance Evaluation of Propeller for High Altitude by using Experiment and Computational Analysis (시험과 전산해석을 이용한 고고도용 프로펠러 성능 분석)

  • Park, Donghun;Cho, Taehwan;Kim, Cheolwan;Kim, Yangwon;Lee, Yunggyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.12
    • /
    • pp.1035-1047
    • /
    • 2015
  • Wind tunnel experiment and computational analysis have been carried out to evaluate the performance of propeller for scale electric-powered HALE UAV, named EAV-2H+. Performance curves are measured for three propellers and their adequacy for EAV-2H+ installation is examined through consideration of operating conditions. Decline in performance coefficients is observed in low rpm region. Also, the effect of transition tape on propeller performance is measured and analyzed. The computational performance analyses are carried out by using commercial CFD program. The thrust and power coefficient from computations show good agreement with experimental results. Performance coefficients are compared and the influence of measurement device which contributes to discrepancy of the results is examined. Transition SST model is confirmed to yield the tendency of performance decline in low rpm range, similar to experimental observation. The decrease in aerodynamic performance of blade element due to low Reynolds number is identified to cause the decline in propeller performance. Analyses for high altitude conditions confirms degradation in propeller performance.

The Study on the Fire Resistance Performance of the CFT (Concrete filled Tube) Column According to the Concrete Compressive Strength and Load Ratio (콘크리트 압축강도 및 하중비에 따른 CFT기둥의 내화성능에 관한 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.44-51
    • /
    • 2010
  • This study, to develop the technology of the fire resistance design of CFT structure based on fire resistance performance design, was suppose to use as basic data for performance design through a measure of temperature and deformation of the CFT specimen as parameter is the concrete compressive strength and load ratio. In accordance with KS F 2257-1 and 7, 24 MPa and 40 MPa and the load ratio of 0.9, 0.6 and 0.2 were imposed on a square column and as a result of evaluating in accordance with the fire resistance criteria, in case of 24 MPa, the fire resistance performance was improved by 73 minutes when the load ratio was reduced by 0.3. And when it comes to 40 MPa, the fire resistance was 31 minutes and 180 minutes when a load ratio was 0.6 and 0.2, respectively. As a result of evaluating fire resistant performance depending on variation of internal concrete strength, it proved that the higher the strength the lower the fire resistance.

Optimum Design of the Ground-Coupled Heat Pump Systems according to Heat Pump Unit Performance (열펌프 유닛 성능과 지열원 냉난방 시스템 설계에 관한 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.193-193
    • /
    • 2011
  • 현재까지 대부분의 지열원 열펌프 시스템에 관한 연구는 열펌프 유닛과 지중열교환기에 대해 개별적으로 수행되었으며, 열펌프 유닛과 지중열교환기 설계 및 최적화의 공통변수인 지중순환수 유량에 따른 시스템 전체에 대한 연구성과는 매우 미미한 실정이다. 본 연구에서는 현재 국내에서 인증되어 보급되고 있는 물매물 지열원 열펌프 유닛의 성능 자료를 분석하고, 지중순환수 유량 변화에 따른 물대물 열펌프 유닛의 성능 실험 및 지중열교환기 형상에 관한 설계 및 분석을 수행하여 지열원 열펌프 시스템 최적화에 관한 기반 기술 확보하고자 하였다. 현재 국내의 물대물 지열원 열펌프 유닛의 냉방 및 난방 조건에서의 최소 인증 COP는 각각 4.1과 3.45이다. 다양한 용량 및 성능을 갖는 국내 인증 물대물 지열원 열펌프 유닛에 대한 정량적 성능 분석을 위하여 3.5kW(1RT) 용량당의 지중순환수 유량과 COP를 고찰하였다. 냉방운전시 3.5kW 단위 용량당 열펌프 유닛의 지중순환수 유량은 10.73에서 18.52LPM을 나타냈으며, 난방운전에는 10.41에서 18.16LPM을 나타냈다. 이때, 냉방 COP는 4.1에서 5.4의 값을 나타냈으며, 난방 COP는 각각 3.5에서 4.2를 나타냈다. 인증 열펌프 유닛에서 지중순환수 유량과 열펌프 유닛의 냉난방 성능은 일정한 경향성을 나타내지 않았다. 지중순환수 유량에 따른 지열원 열펌프 유닛과 시스템의 성능을 정량적으로 분석하고자 지중순환수 유량 변화에 따른 물대물 지열원 열펌프 유닛 성능 실험을 수행하고 이를 기반으로 지중열교환기를 설계 및 분석하였다. 냉난방 각 운전모드에서 ISO 13256-2 규격과 NRGT 101 규격을 기준으로 지중순환수와 부하측 유량 6LPM 에서 36LPM 사이에서 변화시키며 성능 실험을 수행하였다. 냉방 및 난방모드 모두 유량이 증가함에 따라 열펌프 유닛 COP가 증가하였으나, 유량 증가에 따른 열펌프 유닛 COP 증가율은 감소하였다. 지중순환수 유량이 18LPM 이상에서는 COP 상승폭은 미소하였다. 기존문헌의 부하 산정자료와 열펌프 유닛 실험 성능 데이터를 이용하여 지식경제부 고시 2009-332호에 준하여 수직밀폐형 지중열교환기를 설계하고 순환펌프 소요동력을 이용하여 시스템 COP를 분석하였다. 지중열교환기 설계 시 국내에서 가장 많이 사용되고 있는 상용지중열교환기 설계프로그램인 GLD 프로그램을 사용하였다. 지중순환수와 부하측 2차 유체 유량 증가 시에 열펌프 유닛 COP 증가율 대비 시스템 COP 증가율은 감소하였으며, 난방모드에서는 일정 유량 이상에서는 열펌프 유닛 COP는 증가하였으나, 시스템 COP는 감소하였다. 또한, 지중순환수 유량 증가에 따라 지중열교환기 길이가 증가하였으며, 냉난방시의 지중열교환기 길이차이가 증가하였다. 지열원 열펌프 시스템의 고효율화 및 시공비 절감을 통한 경제성 확보를 위해서는 지열원 열펌프 유닛 성능과 지중열교환기 형상 공통 변수인 지중순환수 유량을 함께 고려하여 시스템을 설계하여야한다.

  • PDF

Manufacture and Evaluation of Small Size PEMFC Stack Using Carbon Composite Bipolar Plate (탄소복합소재 분리판을 이용한 소형 고분자전해질 연료전지 스택 제작 및 성능분석)

  • Han, C.;Choi, M.;Lee, J.J.;Lee, J.Y.;Kim, I.T.;An, J.C.;Shim, J.;Lee, H.K.
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.81-88
    • /
    • 2010
  • Small size polymer electrolyte membrane fuel cell (PEMFC) stacks were prepared using carbon composite and graphite bipolar plates and their performances were evaluated on reactant gas and operating time. In comparison to single cell and stack, it was identified that home-made bipolar plate was well-designed to maximize stack performance as high as that of single cell. During long-term operation, the performances of stacks using two different kinds of bipolar plates were compared. The decrease of performance in both stacks was accelerated with increasing load current. It was observed from stack test that the stack performance using carbon composite bipolar plate was very similar to that using graphite bipolar plate.

Seismic Performance of Reinforced Concrete Shear Wall Buildings with Piloti (필로티를 갖는 철근콘크리트 전단벽식 건물의 내진성능)

  • Kwon Young-Wung;Kim Min-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.587-594
    • /
    • 2005
  • The purpose of seismic design is to ensure the serviceability of buildings against earthquake, which might be occurred during the service life of buildings, and to minimize the loss of life by preventing their failure under strong earthquake. The lack resistance of walls resulting from a tendency toward high-rise apartment buildings with shear walls and use of piloti would lead to a concentration of inelastic behaviors in their weak story. In this study, the seismic performance of reinforced concrete shear wall buildings haying piloti was analyzed by using the evaluation techniques which was proposed by FEMA 273 and ATC-40. The results from comparison with these two techniques are summarized as follows.; The results of elastic analysis method for seismic performance evaluation show that the effect of piloti and building height decrease performance index. In case of shear wall building, the state of insufficient shear stress governs their overall performance and it becomes evident in the case of the buildings with more than 25 stories. For the buildings of piloti, the change of mass, weak story, as well as insufficient shear stress, decrease the performance index rapidly compared with the performance index of the buildings without piloti. The results, obtained from the nonlinear static analysis using capacity spectrum method, indicate that the performance Point increases for the structure having Piloti and high story. Also, deformation limits of buildings satisfy the allowable criteria at the life safety level, but the immediate occupancy level is exceeded in buildings which have more than 25 stories.

Power Consumption Analysis of the Wibro System Using Pilot Control of Uplink Symbol (상향링크 Symbol의 Pilot 제어를 적용한 Wibro 시스템의 전력소비량 분석)

  • Choi Jung-Hun;Kim Nam;Nam Chang-Sup
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.8
    • /
    • pp.1-7
    • /
    • 2006
  • In this paper, proposed the method to increase the battery life of the Wibro terminal by reducing its power consumption. The amount of power consumption was analysed. And as the results, it is shown that the suggested method can be reduced the power consumption. The performance of the proposed system, which control the number of pilot of symbol, analysed by the simulation. It is shown that the power consumption of the terminal can be reduced by the reduction of the CINR for the percentage of pilot per symbol, as 0.48dBm for 10% and 0.95dBm for 20%, which can be accomplished by changing the current system of having the fixed number of pilot.

  • PDF

Adaptive TR Scheme for PAPR Reduction in OFDM Systems (OFDM 시스템의 PAPR 감소를 위한 적응적 TR 기법)

  • Lim, Dae-Woon;Noh, Hyung-Suk;No, Jong-Seon;Shin, Dong-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7C
    • /
    • pp.554-561
    • /
    • 2008
  • For the tone reservation (TR) scheme in orthogonal frequency division multiplexing (OFDM), there exists a trade-off between peak to average power ration (PAPR) reduction performance and data transmission rate. While PRT set is fixed in the conventional TR scheme, the proposed scheme adaptively select the PRT set according to the PAPR of the input OFDM symbol. It is shown that the PAPR reduction performance of the proposed scheme is better than that of the conventional scheme when the data transmission rate is the same.

고리 1호기 수명 연장을 위한 압력용기 중성자 조사량 감소방안

  • 서보균;신창호;김종경
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.777-782
    • /
    • 1998
  • 원자로 압력용기의 건전성은 원전의 수명과 직결되며, 압력용기는 운전기간동안 중성자의 조사에 의해 재료의 성질이 저하된다. 중성자 조사량 감소방안을 도출하기 위해 MCNP코드를 이용, 고리 1호기 14주기 원자로심을 3차원으로 모델링하고, 원자로심 핵연료집합체를 제외한 주변구조물에 새로운 추가차폐체를 설치하여 조사량 감소에 효과가 있는 위치를 찾고, 여러 재질의 차폐 성능도 평가하였다. 분석결과, Ta 패드를 이용한 설계안의 경우에 압력용기 용접부위에서 약 32% 정도의 속중성자 조사량 감소가 있음을 확인하였다.

  • PDF

The comparison of treating finishing agent using foaming and padding method (거품과 패딩법을 이용한 가공제 처리 비교)

  • 신유식;이기풍;송병갑;이형달;박철용
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.235-236
    • /
    • 2003
  • 섬유의 습식 가공은 에너지 집약적 산업이다. 대부분의 에너지는 가공시 사용된 많은 양의 수분을 증발시키고, 건조하는데 소모되어진다. 따라서 거품가공은 물 소비를 감소시켜 에너지를 절약하고 폐수를 감소시키는데 주된 목적이 있다(1). 거품가공은 직물에 부가된 물의 양을 감소시켜 건조단계에서 상당한 에너지 소비(30~80%)를 감소시키는 것으로 알려져 있고(2~3), 최근에는 낮은 wet pick-up율에 의한 가공제 처리의 성능 및 수지의 가교분포에 대한 효과 등에 관한 많은 연구가 이루어지고 있으나 미흡한 점이 많이 보고되고 있다.(4~7) (중략)

  • PDF

1, 2성분계 DSA 전극의 제조와 성능 평가

  • Park, Yeong-Sik;Kim, Dong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.464-467
    • /
    • 2008
  • 성능이 우수한 다성분계 전극을 개발하기 위하여 Pt, Ru, Sn, Sb 및 Gd의 5 종류 금속을 이용하여 1성분계 전극의 성능과 산화제 생성량 및 2성분계 전극의 성능과 산화제 생성 경향을 고찰하여 다음의 결과를 얻었다. 1. RhB 농도 감소는 Ru/Ti > Sb/Ti > Pt/Ti > Sn/Ti > Gd/Ti 전극의 순서로 나타났으나 단위 전력당 2분간 제거된 RhB 농도 감소는 Ru/Ti > Sb/Ti > Pt/Ti > Gd/Ti > Sn/Ti 전극의 순서로 나타났다. 생성된 산화제 농도는 ClO$_2$ > free Cl > H$_2$O$_2$ > O$_3$의 순서였으며 Gd/Ti 전극의 경우 산화제가 거의 생성되지 않는 것으로 나타났다. 모든 전극에서 OH 라디칼이 거의 생성되지 않는 것으로 나타났다. Ru/Ti와 Sb/Ti 전극의 높은 RhB 분해와 산화제 생성 농도는 정확하지는 않지만 상관관계가 있는 것으로 나타났다. 2. Ru계 2성분 전극(Ru-Gd/Ti, Ru-Pt/Ti, Ru-Sn/Ti 및 Ru-Sb/Ti)은 모두 1성분계 전극보다 RhB 분해성능이 높아지는 것으로 나타났으며, Ru계 2성분 전극 중 가장 성능이 우수하였던 전극은 Ru:Sn=9:1 전극으로 나타났다. Sn-Sb/Ti 전극은 Sn:Sb=1:9의 전극 성능이 우수한 것으로 나타났으나 Sb/Ti 전극과의 차이는 크지 않은 것으로 나타났다. Pt계 전극(Pt-Gd/Ti, Pt-Sn/Ti, Pt-Sb/Ti)은 대체로 두 성분 혼합에 따른 RhB 분해효과 상승은 없는 것으로 나타났다. 2성분계 전극 중 RhB 제거 성능이 가장 우수하였던 Ru:Sn=9:1 전극에서 4종류의 산화제 생성 농도가 높은 것으로 나타났다. Ru:Pt=9:1 전극은 RhB 분해 성능이 5 전극 중 가장 낮았으며, 산화제도 생성량이 가장 적은 것으로 나타났다. Ru-Sn/Ti 계 전극의 RhB 분해 성능과 산화제 생성 농도가 실험한 모든 1, 2성분계 전극에서 높은 것으로 나타나 향후 3, 4성분계 전극 제조시 이를 바탕으로 제조하고 다른 물질들은 보조재료로서 사용할 필요성이 있는 것으로 사료되었다.

  • PDF