• Title/Summary/Keyword: 설정 압력

Search Result 393, Processing Time 0.026 seconds

A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States (저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구)

  • Na, Nan-Ju;Kwon, Kee-Choon;Bien, Zeungnam
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.3 no.2
    • /
    • pp.18-35
    • /
    • 1993
  • The water level control system of the steam generator in a pressurized water reactor and its control problems are analysed. In this work the stable control strategy during the low power operation and transient states is studied. To solve the problem, a fuzzy logic control method is applied as a basic algorithm of the controller. The control algorithm is based on the operator's knowledges and the experiences of manual operation for water level control at the compact nuclear simulator set up in Korea Atomic Energy Research Institute. From a viewpoint of the system realization, the control variables and rules are established considering simpler tuning and the input-output relation. The control strategy includes the dynamic tuning method and employs a substitutional information using the bypass valve opening instead of incorrectly measured signal at the low flow rate as the fuzzy variable of the flow rate during the pressure control mode of the steam generator. It also involves the switching algorithm between the control valves to suppress the perturbation of water level. The simulation results show that both of the fine control action at the small level error and the quick response at the large level error can be obtained and that the performance of the controller is improved.

  • PDF

Design and Characterization of a Microwave Plasma Source Using a Rectangular Resonant Cavity (마이크로웨이브 공진 공동을 이용한 플라즈마 원의 설계 및 특성)

  • Kim, H.T.;Park, Y.S.;Sung, C.K.;Yi, J.R.;Hwang, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.5
    • /
    • pp.408-418
    • /
    • 2008
  • The rectangular resonant cavity was designed and characterized as a microwave plasma source for focused ion beam. The optimum cavity was calculated analytically and analyzed in detail by using HFSS(High Frequency Structure Simulator). Since the resonant cavity can be affected by the permittivity of quartz chamber and plasma, the cavity is designed to be changeable in one direction. By observing the microwave input power at which the breakdown begins, the optimum cavity length for breakdown is measured and compared with the calculated one, showing in good agreement with the optimum length reduced by 10cm according to the permittivity change in the presence of quartz chamber. The shape of breakdown power curve as a function of pressure appears to be similar to Paschen-curve. After breakdown, plasma densities increase with microwave power and the reduced effective permittivity in the cavity with plasma results in larger optimum length. However, it is not possible to optimize the cavity condition for high density plasmas with increased input power, because too high input power causes expansion of density cutoff region where microwave cannot penetrate. For more accurate microwave cavity design to generate high density plasma, plasma column inside and outside the density cutoff region needs to be treated as a conductor or dielectric.

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF

Physicochemical Properties and Antioxidant Activities of Maillard Reaction Products from Hydrolyzed Wheat Gluten (소맥 gluten 산가수분해물을 이용한 마이야르 반응물질의 이화학적 특성 및 항산화성)

  • Kim, Yoon-Sook;Moon, Ji-Hye;Choi, In-Wook;Choi, Hee-Don
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.122-130
    • /
    • 2009
  • Maillard reaction products (MRPs) were produced from aqueous solution of various sugars with hydrolyzed wheat gluten (HWG) with different temperatures, pressures, pH values and solvents. The physicochemical properties of MRPs were investigated and DPPH and hydroxyl radical scavenging activity and sensory properties were also assessed. MRPs from ribose and HWG evidenced the highest preference for meaty flavor and antioxidant activity and also evidenced higher antioxidant activity with larger pH reductions and higher browning index increases than were observed in other MRPs. The antioxidant activities were increased with increased reaction temperature and pressure. The most preferred meaty flavor was obtained from MRPs with ribose at 140$^{\circ}C$ in an oil bath with the pH adjusted to 9 in water as a solvent, and heated for 30 mins.

Temperature Distribution in Water Cascading Horizontal Retort (열수식 살균기의 온도 분포에 관한 연구)

  • Chung, Myong-Soo;Ahn, Tae-Hoe;Lee, Yong-Gab;Yoo, Moo-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.827-833
    • /
    • 1995
  • Temperature distribution tests for a water cascading horizontal retort utilizing superheated water with overpressure as a heating medium were carried out under three different loading conditions, that is, empty(P-0), half-fully(P-3000) and fully(P-6000) loaded operating conditions. Tank volume and full loading capacity of sterilizer used for this study were about 5,900 liter and 1,140 kg(6000 pouches having 190 g weight each), respectively. Set point condition for sterilization was $122^{\circ}C$, 23 minutes and pressure was maintained in the range of $1.8{\sim}2.0\;kg/cm^2$ during sterilization. For each experiment, time-temperature data and F values were obtained from temperature microprocessor($F_0$ monitor). There were significant variations in the temperature distribution at different positions in the sterilizer. The temperature distribution was also affected by the pouch loading condition significantly. The application of the temperature distribution test to a product (retort pouched curry sauce) was conducted at the fully(P-6000) loading condition. Although heat transfer parameters($f_h\;and\;f_c$), and F values were varied with the position of sterilizer, sensory evaluation showed that the temperature distribution of the sterilizer used in this study didn't affect the quality of retorted curry sauce.

  • PDF

Effect of a Combined Treatment of High Hydrostatic Pressure and Carbonation on the Quality Characteristics of Valencia Orange Juice (초고압과 Carbonation의 병합처리가 오렌지쥬스의 품질 특성에 미치는 영향)

  • Yun, Hye-Suk;Park, Seok-Jun;Park, Ji-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.974-981
    • /
    • 1997
  • A combined treatment of high hydrostatic pressure and carbonation was used to inactivate pectinesterase (PE) and sterilize microorganisms in Valencia orange juice without major changes in its nutritive components. Quality characteristics of Valencia orange juice, such as microorganisms, PE activity, vitamin C content and color, were evaluated after it was treated with pressure, carbonation-and-pressure, and heat. Quality changes during storage at $4^{\circ}C$ and $30^{\circ}C$ after the treatments were also investigated. Pressurized orange juice (pressurized at 600 MPa for 10 min at $20^{\circ}C$) showed 7.0% residual PE activity, while the carbonated-and-pressurized orange juice (207 $kPa-CO_2$ gas pressure, pressurized at 600 MPa for 10 min at $20^{\circ}C$) showed 0%. Pressurization at 400 MPa or higher decreased the population of microorganisms in the orange juice to less than 10 CFU/mL. Carbonated-and-pressurized orange juice showed slight decrease in vitamin C content when stored at both $4^{\circ}C\;and\;30^{\circ}C$. While heat-treated ($90^{\circ}C$ for 60 sec) orange juice showed 75% decrease in vitamin C content when stored at $30^{\circ}C$. L value (lightness) and b value (yellowness) of carbonated-and-pressurized orange juice were higher than those of heat-treated orange juice when they were stored at $4^{\circ}C$ for 30 days.

  • PDF

Fracture Characteristics of Ductile Fiber Reinforced Cement based Composites by Collision of Steel Projectile (비상체의 충돌에 의한 고인성 섬유보강 시멘트복합체의 파괴특성)

  • Nam, Jeong-Soo;Kim, Gyu-Yong;Kim, Hong-Seop;Kim, Jung-Hyun;Han, Sang-Hyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.92-100
    • /
    • 2015
  • The aim of this study is to evaluate the fracture characteristics of ductile fiber reinforced cement based composites with 1.5 volume ratio of polyvinyl alcohol and steel fiber by high velocity impact of steel projectile. We used gunpowder impact facility to evaluate the fracture characteristics of ductile fiber reinforced cement based composites by collision of steel projectile, and the impact velocity was from about 150 to 1,000m/s. The results of evaluation on the fracture characteristics of ductile fiber reinforced cement based composites were penetration grade, which is the kinetic energy more than three times of no-fiber reinforced specimen (Plain). In addition, ductile fiber reinforced cement based composites did not occurred critical damage other than the debris. In the case of mass loss, Plain specimen was proportional to kinetic energy of steel projectile, while ductile fiber reinforced cement based composites was not significantly affected by kinetic energy of steel projectile. In particular, this tendency had a close relationship with the fracture characteristics of back side of specimens, and the scabbing inhibiting efficiency of PVA specimen was higher than S specimen. In the results of verifying relationship between front and back side calculated by local damage, scabbing occurred at the region close to the back side in the ductile fiber reinforced cement based composites unlike Plain specimen. Thus, in this study, we examined principal fracture behaviors of ductile fiber reinforced cement based composites under collision of steel projectile, and verified that impact resistance performance was improved as compared to Plain specimen.

Distributional Patterns of Understory Vegetation at Mt. Geumdae's Protected Area for Forest Genetic Resources (금대봉 산림유전자원보호림의 하층식생 분포양상)

  • Chun, Seung-Hoon;Lee, Hyung-Sook;Lim, Jong-Hwan
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.339-350
    • /
    • 2009
  • This study was carried out to investigate distributional condition of rare plants and useful plant resources, and to verify distributional patterns of understory vegetation associated with the upper layer's vegetation structure. Total 59 families, 160 genera, 218 kinds of vascular plants were identified at the study site including 6 rare plants designated by Korea Forest Service (Lloydia triflora Bak., Trillium kamtschaticum Pall., Lilium distichum Nakai, Anemone koraiensis Nakai, Iris odaesanensis Y.N. Lee, Viola diamantica Nakai). Twenty three species of useful plant resources were also identified at the site; 8 of them showed clustered distributions and the others were prone to scatter. Actual vegetation of this study area consisted of one natural community dominated by Quercus mongolica Fisch. and three disturbed communities of Larix kaempferi (Lamb.) Carriere, Abies holophylla Max. and/or a herbaceous vegetation resulting from forest removal and strong wind of mountain top. This classification was strongly supported by cluster analysis based on the surveyed plot data. Distributional patterns of understory vegetation within forest stand were somewhat related to overstory vegetation structure, but showed a different tendency according to site condition, species composition, and competitive pressure among understory vegetation. Therefore, in order to protect the important understory components as forest genetic resources, forest treatments such as density control of overstory should be implanted based on understanding of impact on understory's dynamics and growing condition.

Development of Integrated Water Resources Evaluation Index (통합수자원평가지수의 개발)

  • Lee, Dong-Ryul;Choi, Si Jung;Moon, Jang Won
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.10
    • /
    • pp.1017-1028
    • /
    • 2013
  • The purpose of this research is to develop an Integrated Water Resources Evaluation Index (IWREI) which can used to assess the performance of water resources projects in a regional perspective focusing on three major sectors including water use, flood, and river environment in water resources policies. The IWREI is estimated by integrating the Water Use Vulnerability Index (WUVI), the Flood Vulnerability Index (FVI), and the River Environment Vulnerability Index (REVI) which represent the vulnerability in each sector. These indices consist of total 26 indicators selected from the pressure indicators representing the causes of damages in water use, flood, and river environment, the state indicators and the response indicators. The estimated index describes the vulnerability and effectiveness of policies with five levels: Low, Medium Low, Medium, Medium High, and High. The results of evaluating total 115 hydrological units in Korea using the WUVI, FVI, REVI, and IWREI indicate that the project effectiveness in water resources policies is clearly verified by the improved index results compared to the past (early 1990s). Regional vulnerability and evaluation indices developed in this research could be used to establish goals of water resources policy and to select priority regions for project implementation.

The Structural Integrity Test for a PSC Containment with Unbonded Tendons and Numerical Analysis I (비부착텐던 PSC 격납건물에 대한 구조건전성시험 및 수치해석 I)

  • Noh, Sanghoon;Jung, Raeyoung;Kim, Sung-Taek;Lim, Sang-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.523-533
    • /
    • 2015
  • A reactor containment acts as a final barrier to prevent leakage of radioactive material due to the possible reactor accidents into external environment. Because of the functional importance of the containment building, the SIT(Structural Integrity Test) for containments shall be performed to evaluate the structural acceptability and demonstrate the quality of construction. An initial numerical analysis was performed to simulate the results obtained from the SIT for a prestressed concrete(PSC) structure. But the analysis results by the initial model expected smaller displacements than the measured ones by 30% at some locations. Accordingly, the research and development to improve the initial model to corelate the measured results of the SIT more properly have been performed. In this paper, the effects of the loss of concrete due to duct for tendons and the contact of duct and tendons in un-bonded tendon system are mainly evaluated based on the preliminary analysis results. In addition, the importances of the proper definition of mesh connectivity among structural elements of concrete, liner plates, rebars and tendons are discussed.