• Title/Summary/Keyword: 설계편심

Search Result 165, Processing Time 0.02 seconds

A Study on the Static Eccentricities of Buildings Designed by Different Design Eccentricities (설계편심의 크기에 따른 비틀림 비정형 건물의 최종 정적편심 크기의 비교에 관한 연구)

  • Lee, Kwang-Ho;Jeong, Seoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.33-40
    • /
    • 2012
  • To reduce the vulnerability of torsional irregular buildings caused by seismic loads, the torsional amplification factor was introduced by the seismic code. This factor has been applied differently in a variety of seismic codes. In this study, the final static eccentricity, and the lateral and torsional stiffness ratios of buildings designed with different design eccentricities were compared. The increment of the torsional amplification factor resulted in a decrement of the final static eccentricity of the building. However, after reaching the maximum value of this factor, the final static eccentricity of the building increased again. The final static eccentricity of the building designed by multiplying the sum of the inherent and accidental eccentricity by the torsional amplification factor was zero or had a minus value, depending to the position of the vertical element.

Design of the Finite Schematic Eye with GRIN Crystalline Lens Considering Iris Eccentricity (홍채 편심을 고려한 GRIN 수정체를 갖는 정밀모형안 설계)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.61-64
    • /
    • 2011
  • Purpose: The purpose of this study was to design the finite model eye with GRIN lens similar to actual eye, which considered the effect of iris eccentricity on eyes. Methods: By using the finite model eye with Radial GRIN and Spherical GRIN, which were designed previously, the location of iris was eccentrically located by 0.5 mm in the direction of nose to show the same eye as actual one. For ray trace and design, Code V program of Optical Research Associates (ORA) was adopted. Results: Designed model eye was compared to actual eye depending on iris eccentricity and the model eye which showed reduced value was corrected according to actual eye to design the finite model eye. Conclusions: Ocular optical systems considered the point that iris was a rotational asymmetry and designed the finite model eye with GRIN lens, which was similar to actual eye, by considering the effect of iris eccentricity on eye.

The Response Modification Factor of Inverted V-type Braced Steel Frames (역V형 가새골조의 반응수정계수)

  • Ahn, Hyung Joon;Jin, Song Mei
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • In this study of Eccentric Braced Frames have identified the following target eccentricity on the length of the inelastic behavior of the reaction by calculating the correction factor by comparing it to the value suggested by the earthquake provided material for the rational design aims to There are. As a variable-length V-braced frame analysis model stations were set up. Eccentricity faults in the model according to the length stiffness ratio, the maximum amount of energy dissipation were analyzed base shear and multi-layered model of the reaction from the eccentricity correction factor calculated on the length of the building standards proposed by KBC 2009 in response eccentricity correction factor calculated from The length varies. does not have the same response modification factor was confirmed.

Verification of the Torsional Amplification Factor for the Seismic Design of Torsionally Imbalanced Buildings (비틀림 비정형 건물의 내진설계를 위한 우발편심 비틀림 증폭계수 검증)

  • Lee, Kwang-Ho;Jeong, Seoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.67-74
    • /
    • 2010
  • Because of the difference between the actual and computed eccentricity of buildings, symmetrical buildings will be affected by torsion. In provisions, accidental eccentricity is intended to cover the effect of several factors, such as unfavorable distributions of dead- and live-load masses and the rotational component of ground motion about a vertical axis. The torsional amplification factor is introduced to reduce the vulnerability of torsionally imbalanced buildings. The effect of the torsional amplification factor is observed for a symmetric rectangular building with various aspect ratios, where the seismic-force-resisting elements are positioned at a variable distance from the geometrical center in each direction. For verifying the torsional amplification factor in provisions, nonlinear reinforced concrete models with various eccentricities and aspect ratios are used in rock. The difference between the maximum displacements of the flexible edge obtained between using nonlinear static and time-history analysis is very small but the difference between the maximum torsional angles is large.

Design of eccentric forging process for camber bolts using finite element method (유한요소법을 이용한 캠버볼트의 편심단조 공정설계)

  • Kim, Kwan-Woo;Qiu, Yuan-Gen;Cho, Hae-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.320-324
    • /
    • 2016
  • A new eccentric forging process for camber bolts has been suggested in this study. The camber bolt is manufactured by a two-step process: the typical forging process for normal bolts and the trimming process for the eccentric flange. The processes are performed under high forging load and generate a large amount of chip during trimming. A new forging process has been required in order to overcome these problems. The eccentric forging is the new process in which the load axis is offset from the central axis, as against central load applied in a typical forging process. The eccentric forging process could reduce forging load and save the amount of chip. In order to manufacture camber bolts by an optimum process, it is required to adjust the geometry of eccentric die and the offset from the central axis.

The Design Eccentricity for Torsionally Unbalanced Structure (비틀림 거동을 하는 구조물의 설계 편심)

  • 조소훈;이명규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.63-72
    • /
    • 2001
  • In this paper, to satisfy the safety and economy immediately, we assume the center of lateral load in case the dynamic motion of the torsionally unbalanced structure is transformed into the static lateral load using modal analysis and proposes a method to control the design eccentricity in order to make the center of lateral load coincide with the center of strength. And when the structure is designed by proposed method, it is shown that the structure designed by proposed method does not demand excessive additional ductility in comparison with the structure designed by provisions of other seismic building code.

  • PDF

An Evaluation of Blast Resistance Capacity of RC Columns under Eccentric Load (편심하중을 받는 철근콘크리트 기둥의 폭발 저항성 평가)

  • Kim, Han-Soo;Lee, Jae-Yong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.148-151
    • /
    • 2011
  • 현재 방폭설계 관련 설계지침은 기둥제거시나리오를 이용한 대체하중경로법을 주로 적용하고 있지만, 실제로 폭발이 발생하였을 때 기둥의 완전한 파괴가 일어나지 않을 경우 이 방식을 적용하는 것은 적합하지 않다. 따라서 본 논문에서는 비선형 동적 해석 프로그램인 AUTODYN을 이용해 편심하중을 받는 철근 콘크리트 기둥의 잔존 폭발 저항 성능을 평가하는 방식을 제안하였다. 해석결과를 비교해보면 TNT양과 축하중이 클수록 철근콘크리트 기둥의 잔존 폭발 저항 성능이 감소되었다. 이것은 폭발이 발생하기전의 기둥의 편심하중에 의한 응력상태에 따라 폭발 저항 성능이 달라짐을 알 수 있다.

  • PDF

Aberration Correction of an Off-axial-field Two-mirror System Using a Decentered Aperture (비축시야 2반사광학계에서 조리개의 편심을 이용한 수차보정)

  • Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.20-25
    • /
    • 2020
  • To design a wide-field two-mirror system, the system must feature an off-axial field, to avoid ray obstruction and field screening by the secondary mirror. The off-axial aberrations of the system cannot be corrected sufficiently, though, because there are only a few design parameters. The present study designs an improved off-axial-field two-mirror system using a decentered aperture stop.

Torsional Behavior of the stringer on the Steel Railway Bridge due to Eccentric Loads (편심 하중에 의한 강철도교 세로보의 비틀림 거동)

  • Kim, Seong-Nam;Sung, Ik-Hyun;Kim, Jong-Heun;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.63-71
    • /
    • 2004
  • The centroid of rail doesn't coincide with the centroid of stringer on target truss bridge. If there is no eccentricity on the bridge, bending stress works only. But in the real design and execution, not only bending stress works but also torsional stress does because of it's eccentricity. So this study evaluates how much the torsional stress by eccentricity effects joint members on the bridge. We investigate the possibility to control torsional stress if we model longitudinal bracing between stringers.

Critical Loads of Eccentrically Loaded Struts with Thin-Walled Open Sections (편심하중을 받는 박벽개단면 압축재의 임계하중)

  • 나영진;이수곤
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.135-140
    • /
    • 1996
  • Single angle or channel with thin-walled open section can be used as compression member for example as web member in truss. In this case the inevitable eccentricity due to fabrication is commonly neglected in structural design. However eccentricity effect should be considered in the member design, especially in case of compression member. The critical loads of compression members that buckle by twisting or by a combination of bending and twisting are to be determined by solving governing differential equations. In this paper, the investigations are limited to the rolled channels([), equal-leg angles(L), lipped channels(C) and the applied loads are assumed to have some eccentricities.

  • PDF