The Dosimetry of Radiosurgery using of Rando Phantom (Rando phantom을 이용한 Radiosurgery에 관한 Dosimetry)

  • Kim, Sung-Kyu;Shin, Sei-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.113-119
    • /
    • 1990
  • The stereotactic radiosurgery using ionizing radiation of high energy is a technique for exadicating intracranial small tumors, which are inaccessible or unsuitable for open surgical technique. For such a small field radiosurgery. TLD or film dosimetry is essential. The three dimensional dose planning of radiosurgery was performed with dose planning computer system (Therac 2300). The target dose distribution and its error according to patient position were discussed. And were measured of circular cone which specially designed in our Hospital. The position error of Rando Phantom compared with CT were O.4mm in the AP-LAT section and in the AP-VERT section, 1.0mm in the AP-VERT $45^{\circ}$section. The ratio of accuracy of the gantry and couch rotation were 1.5mm diamteter for centeral axis of I8MeV linear accelerator. Our study suggested that radiosurgery of small field in our department will be appropriate for clinical application.

  • PDF

Acoustic Voice Tremor index in the measurement of voice tremor: Development and validation (음성 떨림 측정을 위한 AVTI(Acoustic Voice Tremor index)의 개발과 검증)

  • Geun-Hyo Kim;Yeon-Woo Lee
    • Phonetics and Speech Sciences
    • /
    • v.16 no.2
    • /
    • pp.91-97
    • /
    • 2024
  • The aim of this study was to develop and validate the Acoustic Voice Tremor index (AVTI) for the acoustic measurement of voice tremor. A total of 71 normal adults and 41 patients with voice tremor participated in the study. Vowels /a/ were recorded for at least five seconds. Three seconds of vowel stable duration were edited to identify measures of 18 variables related to voice tremor using a Praat script. These variables and the overall severity (OS) of auditory-perceptual assessment were used to design the AVTI using linear regression analysis. The linear regression analysis identified four out of the 18 variables as significant, and a regression equation was constructed. Furthermore, internal and external validity studies demonstrated high correlations, with an average of over 0.8. The AVTI demonstrated a high correlation of 0.841 with OS. The AVTI was found to be capable of predicting voice tremor. Further studies should include a larger number of voice samples and a complementary Praat script for further analysis.

Automatic Synchronization of Separately-Captured Facial Expression and Motion Data (표정과 동작 데이터의 자동 동기화 기술)

  • Jeong, Tae-Wan;Park, Sang-II
    • Journal of the Korea Computer Graphics Society
    • /
    • v.18 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • In this paper, we present a new method for automatically synchronize captured facial expression data with its corresponding motion data. In a usual optical motion capture set-up, a detailed facial expression can not be captured simultaneously in the motion capture session because its resolution requirement is higher than that of the motion capture. Therefore, those are captured in two separate sessions and need to be synchronized in the post-process to be used for generating a convincing character animation. Based on the patterns of the actor's neck movement extracted from those two data, we present a non-linear time warping method for the automatic synchronization. We justify our method with the actual examples to show the viability of the method.

Media Production Environment Using Metadata based on Advanced Authoring Format (Advanced Authoring Format기반에서 메타데이터를 활용한 영상제작환경)

  • Mok, Seon-Ah;Kim, Chul-Hyun;Paik, Joon-Ki
    • Journal of Broadcast Engineering
    • /
    • v.13 no.2
    • /
    • pp.274-282
    • /
    • 2008
  • In this paper, we propose from media production environment using meta-data based on advanced authoring format(AAF). The media production system becomes digitalized since the image degradation and data storage should be minimized. For transmitting various contents without loss of meta-data. Editing decision list(EDL)is used in the current broadcasting and cinema environment, which results in inefficient performance. We compared the proposed AAF with the existing EDL cut, and tested successful transmission of the metadata. Based on the experimental results, the proposed AAF contains more video information than EDL.

Design of High Speed , Real-time , and Large Scale Data Storage System for Editing HDTV Data (HDTV 데이터 편집을 위한 고속 실시간 대규모 데이터 저장 시스템의 설계)

  • Lee, Chan-Su;Seong, Yeong-Rak;O, Ha-Ryeong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.5 no.2
    • /
    • pp.223-235
    • /
    • 1999
  • 본 논문에서는 HDTV 데이터를 입출력할 수 있는 고속 실시간 데이터 저장 시스템을 제안한다. 이 시스템은 ⅰ) 방대한 크기를 HDTV 데이터를 고속으로 입출력할 수 있어야 한다. ⅱ)데이타를 연속적으로 입출력할 수 있는 것 외에 데이터를 비선형적으로 랜덤하게 억세스 할 수 있어야 한다. ⅲ)실시간으로 데이터를 재생하기 위해 일정하게 주어진 시스템 입출력 속도를 항상 만족할수 있어야 한다. 이러한 조건을 만족시키기 위해서 여러 개의 하드디스크를 병렬로 연결하고 데이터들을 각각의 하드디스크에 나누어 저장하였다. 하드디스크의 입출력 성능은 하드디스크 아암의 탐색 동작에 의해 크게 좌우되므로 탐색 동작을 효과적으로 제어할 수 있는 방법이 설계되었다. 제안된 시스템은 주제어부, 데이터 분배부, 종제어부로 나뉘며 각각의 하드디스크는 독립도니 종제어부에 의해 제어된다. 제안된 시스템이 주어진 요구사항을 만족하는지를 확인하기 위하여, 제안된 시스템을 DEVS 형식론을 이용하여 구현하고 시뮬레이션 하였다. DEVS 형식론은 이산사건 시스템을 계층적이고 모듈화된 형태로 기술한다. 시뮬레이션 과정에서 발생된 사건들을 분석하였다. 그 결과 제안된 시스템이 주어진 요구사항을 잘 만족함을 보았다.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Color Correction Using Back Propagation Neural Network in Film Scanner (필름 스캐너에서 역전파 신경회로망을 이용한 색 보정)

  • 홍승범;백중환
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.4
    • /
    • pp.15-22
    • /
    • 2003
  • A film scanner is one of the input devices for ac acquiring high resolution and high qualify of digital images from the existing optical film. Recently the demand of film scanners have risen for experts of image printing and editing fields. However, due to the nonlinear characteristic of light source and sensor, colors of the original film image do not correspond to the colors of the scanned image. Therefore color correction for the scanned digital image is essential in film scanner. In this paper, neural network method is applied for the color correction to CIE L/sup *//a/sup *//b/sup */ color model data converted from RGB color model data. Also a film scanner hardware with 12 bit color resolution for each R, G, B and 2400 dpi is implemented by using the TMS320C32 DSP chip and high resolution line sensor. An experimental result shows that the average color correction rate is 79.8%, which is an improvement of 43.5% than our previous method, polygonal regression method.

  • PDF

A Study on Equivalent Square Field in High Energy Photon Beam (고에너지 Photon Beam에 있어서 Equivalent Square Field에 관한 고찰)

  • Kim, Sung-Kyu;Shin, Sei-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.2
    • /
    • pp.83-88
    • /
    • 1987
  • An analytic expression for equivalent square fields and a table are derived using the empirical representations obtained from the measured field size dependence of output for square field in a phantom. The expression is applicable to radiation fields that consistent with the following two assumptions Imposed on these representations. 1) It is a linear function of the logarithm of the field area, and 2) It is approximately the same function for both square and circular field of similar areas. In this paper, the derived tables and BJR table were consulted.

  • PDF

A Study on the Types of Time for Expression as Film Language in Animation (애니메이션의 다양한 시간의 종류와 영상 언어적인 표현에 대한 연구)

  • 김지홍
    • Archives of design research
    • /
    • v.15 no.4
    • /
    • pp.253-262
    • /
    • 2002
  • Without the involvement of time in animation, it cannot be possible to create movement. Therefore, tine is the important element to create animation. In animation, the expression of the emotion of character is more complicate than the appearance. Time is one of element to use for express of the emotion. It can be divided two types of time as the real time and the animation time broadly. The real time has linear, irreversible and analogue form which is in our daily life. And the animation time has multi-direction, reversible, and digital form which can be detected in the movie. For the animation time, there are many types of time that are the running time, the production time, the subjective time, the objective time, the ambiguous time and the universal time etc. This study is to extend and enrich the express as film language through various types of times in animation. Time is one of important element that can be useful method for expressing many unique scenes in film art as film language.

  • PDF

A Study on ARC Therapy of 18MeV Linear Accelerator (18MeV 선형가속기의 ARC Therapy에 관한 고찰)

  • Kim, Sung-Kyu;Shin, Sei-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.2
    • /
    • pp.31-36
    • /
    • 1988
  • In recent years there has been a growing interest in all forms of rotational therapy, and many different types of therapy machines designed for this kind of treatment have become available. To the medical radiation physicist, the dosimetry of rotation therapy has presented a number of interesting problems, and much useful work has been published on the basic data of dose distribution and dosage calculation. The setting dose for ARC therapy were obtained by computer calculation and measurement with cylindrical phantom. Authors compared computer calculation with measured value. And in ARC therapy, the region of maximum dose is shifted from the tumor center. The extent of shift was analyzed by isodose distribution for ARC therapy techniques.