• Title/Summary/Keyword: 선량률 지도

Search Result 89, Processing Time 0.03 seconds

Detection Range Improvement of Radiation Sensor for Radiation Contamination Distribution Imaging (방사선 오염분포 영상화를 위한 방사선 센서의 탐지 범위 개선에 관한 연구)

  • Song, Keun-Young;Hwang, Young-Gwan;Lee, Nam-Ho;Na, Jun-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1535-1541
    • /
    • 2019
  • To carry out safe and rapid decontamination in radiological accident areas, acquisition of various information on radiation sources is needed. In particular, to figure out the location and distribution of radiation sources is essential for rapid follow-up and removal of contaminants as well as minimizing worker damage. The radiation distribution detection device is used to obtain the position and distribution information of the radiation source. In the case of a radiation distribution detection device, a detection sensor unit is generally composed of a single sensor, and the detection range is limited due to the physical characteristics of the single sensor. We applied a calibration detector for controlling the detection sensitivity of a single sensor for radiation detection and improved the limited detection range of radiation dose rate. Also, gamma irradiation test confirmed the improvement of radiation distribution detection range.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

Radiation Exposure Evaluation Depending on Radiation Workers' Locations during Dental Radiography (치과방사선 검사 시 방사선작업종사자의 위치에 따른 방사선 노출 평가)

  • Jeong, Cheonsoo;Kim, Jiyoung
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.433-438
    • /
    • 2015
  • To evaluate the radiation exposure level based on radiation workers' locations in dental radiography, the radiation dose rate in the radiographic room, lead glass, and operation system was measured. To that end, various devices were used, such as a Standard(Max-GLS, Shinhung), a panorama (PCH-2500, Vatech), a cephalometric radiography (PCH-2500), and a cone beam CT (PHT-30LFO, Vatech), as well as a PM1405 equipment as a radiation meter. Radiography conditions were set the same as the factors used in the clinical setting. As the result, the cone beam CT turned out the highest with 98 uSv and the standard showed the lowest level with 0.4 uSv/h. The panorama was measured to be higher than the Cephalo due to its different focus mode. On the lead glass surface and in the operation stand, the oral radiography device, panoramic, and Cephalo all were measured below the recording level. However, the cone beam CT was measured to have the leakage dose. Thus, radiation involved workers should be equipped with appropriate protection tools and reduce radiography time as much as possible. In addition, the structure of the radiation chamber should be also designed efficiently. Dental radiography has continued to grow in recent years, so it is necessary take appropriate protection measures for patients and radiation workers.

Results of Radiation Therapy and Extrafascial Hysterectomy in Bulky Stage IB, IIA-B Carcinoma of the Uterine Cervix (종괴가 큰 병기 IB, IIA-B 자궁경부암에서 방사선치료와 Extrafascial Hysterectomy의 결과)

  • Kim Jin Hee;Lee Ho Jun;Choi Tae Jin;Do Cha Soon;Lee Tae Sung;Kim Ok Bae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.23-29
    • /
    • 1999
  • Purpose : To evaluate the efficacy of radiation therapy and extrafascial hysterectomy in bulky stage IB, IIA-B uterine cervix cancers. Methods and Materials : Twenty four patients with bulky stage IB and IIA-B carcinoma of the uterine cervix were treated with extrafascial hysterectomy following radiation therapy due to doubts of residual disease at Department of therapeutic radiology, Keimyung University, Dongsan Hospital, from April 1986 to December 1997 According to FIGO staging system, there were 7 patients with stage IB, 9 patients with IIA and 8 patients with IIB stage whose median age was 45. Pathologic distribution showed 16 patients with squamous cell carcinoma and 8 patients with adenocarcinoma. Seven patients had tumors that are less than 5cm in size and 17 patients had tumors with larger than 5cm. The mean interval between radiation therapy and extrafascial hysterectomy was 57 days. The radiation therapy consisted of external irradition to the whole pelvis (180 cGy/fraction, mean 4100 cGy) and parametrial boost (for a mean total dose of 5000 cGy) with midline shield (4H 10 cm), followed by intracavitary irradiation up to 7500 cGy to point A (maximum 8500 cGy). The maximum follow up duration was 107 months and mean follow up duration was 42 months. Results :Ten out of 24 patients (41.7%) had residual disease found at the time of extrafascial hysterectomies. Five year overall survival rate (5Y OSR) and five year disease free survival rate (5Y DFSR) were 63.6% and 62.5% respectively. Five year overall survival rate for stage IB and IIA was 71.4% and 50% for stage IIB. There was a significant difference in 5Y OSR and 5Y DFSR between patients with and those without residual disease (negative vs positive, 83.3% vs. 40% (P=0.01), 83.3% vs 36% (P=0.01) respectively). There was a notable tendency of better survival with adenocarcinoma than with squamous cell carcinoma (adenocarcinoma vs squamous cell carcinoma, 85.7% vs. 53.3% (P=0.1), 85.7% vs. 50.9% (P=0.1) of 5Y OSR and 5Y DFS respectivey). Total dose to A point did not make a significant difference in survival rate or the existence of residual lesion (< 7500 cGy, ${\geq}$ 7500 cOy). It was also noted that significantly more frequent local failures have occurred in patients with positive residual disease compared with negative residual disease (5/10 vs. 0/14, p=0.003), There was no death related to the treatment. Conclusion : There was no improvement of residual disease and to the overall survival rate in spite of increased total dose to point A. We conclude that there is a possible beneficial effect of radiation therapy followed by extrafaseial hysterectomy in survival for adenocarcinoma of bulky stage IB and IIA-B uterine cervix. We need to confirm this with longer follow up and with large number of patients.

  • PDF

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Performance Evaluation of the Tumor Tracking Method Using Beam on/off Interface for the Treatment of Irregular Breathing (호흡이 불규칙한 환자의 치료를 위한 Beam on/off Interface를 이용한 종양 추적 치료 방법의 성능 평가)

  • Lee, Minsik
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.343-349
    • /
    • 2018
  • Dose rate regulated tracking is known to be an efficient method which adaptively delivers tracking treatments when patient breathing is irregular. The Motion Management Interface (MMI, Varian Medical System, CA), which provides beam on/off switching during treatment is available for clinic. Study is to test if delivering the adaptive tumor tracking is feasible for irregular breathing using beam switching with MMI. 55 free breathing RPM traces acquired from lung cancer patients are used. The first day RPM traces of the patients are utilized to design preprogrammed tracking MLC patterns, of which periods are intentionally reduced by 20% in order to catch up the variation of patient breathing irregularity in the treatment day. Eligibility criteria for this technique are the variation of amplitude and period less than 20%. An algorithm which determines beam on/off every 100 ms by considering the preprogrammed (MLC) positions and current breathing positions is developed. Tracking error and delivery efficacy are calculated by simulating the beam-switching adaptive tracking from the RPM traces. Breathing patterns of 38 patients (70%) met the eligibility criteria. Tracking errors of all of the cases who meet the criteria are less than 2 mm (average 1.4 mm) and the average delivery efficacy was 71%. Those of rest of the cases are 1.9 mm and 48%. Adaptive tracking with beam switching is feasible if patient selection is based on the eligibility criteria.

Evaluation of Radiation-induced Apoptosis in Seminiferous Tubule of ICR Mouse after Gamma Irradiation. (감마선을 조사한 ICR 마우스 정세관에서 apoptosis 발생 평가)

  • Jang, Jong-Sik;Kim, Joong-Sun;Kim, Jong-Choon;Kim, Sung-Ho
    • Journal of Life Science
    • /
    • v.19 no.6
    • /
    • pp.799-803
    • /
    • 2009
  • The killing of male germ cells by radiation and other toxicants has recently been attributed to apoptosis, but a critical evaluation of the presence of the different features of apoptosis in each epithelial stage has not been performed. In this study, mouse testes exposed to radiation were examined by light microscopy and terminal transferase-mediated end labeling (TUNEL) with periodic acid-Schiff (PAS) stains to determine whether the cells were apoptotic according to several criteria. Apoptosis was easily recognized by the presence of peroxidase-stained, entirely apoptotic bodies. In the TUNEL-positive cells or bodies, the stained products correlated precisely with the typical morphologic characteristics of apoptosis as seen at the light microscopic level. The changes that occurred from 0 to 24 hours after exposing the mice to 2 Gy of gamma-rays (2 Gy/min) were examined. The numbers of apoptotic cells reached a peak at 12 hours after irradiation and then declined. The mice that received 0-8 Gy of gamma-rays were examined 8 hours after irradiation. Dose-response relationships were generated for each stage of the epithelial cycle by counting TUNEL-positive cells. The dose-response curves were linear- quadratic [y=(-0.014${\pm}$0.009)$D^{2}$+(0.31${\pm}$0.697)D+0.3575. Where y=the number of apoptotic cells per seminiferous tubule, and D=the irradiation dose in Gy, $r^{2}$=0.9] and there was a significant relationship between the frequency of apoptotic cells and the radiation dose. Although the maximum response was produced by 8 Gy, even 0.5 Gy induced marked changes. These changes were most pronounced in B spermatogonia of stage V and the spermatocyte at the mitotic cells of stage XII.

An Evaluation on the Radiation Shielding of the Radwaste Drum Assay Facility (방사성폐기물드럼 핵종재고량 평가시설 구축에 따른 방사선차폐 영향평가)

  • Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Shon, Jong-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • In order to dispose of the LILW(low and intermediate level radioactive waste) stored at KAERI, the radwaste drum assay system will be introduced to evaluate the radioisotopes inventory of stored drums. At present, the construction project of the dedicated assay facility to operate it and carry out routine maintenance of that equipment has been conducting at the radwaste treatment facility. Since that facility will be constructed in front of a 1st radwaste storage facility as well as the radwaste drums to be assayed and the transmission source in the radwaste drum assay system are in that facility, they could act as the radioactive sources and then, would affect the dose rate at the inside and the outside of the facility. Therefore, the radiation shielding should be evaluated through the concrete wall near to the radioactive sources whether the wall thickness is sufficient against the regulations. In this study, the radiation safety for the concrete wall around the radiation controlled area in the radwaste drum assay facility was evaluated by the MCNP code. From the evaluation results, the thickness of those concrete walls which are under consideration of about 30 cm was enough to shield the radiation from the radioactive sources.

Changes of Nutritional Compounds and Texture Characteristics of Peaches (Prunus persica L. Batsch) during Post-irradiation Storage at Different Temperature (감마선 조사와 저장온도에 따른 복숭아의 품질특성 변화)

  • Yun, Hye-Jeong;Lim, Sang-Yong;Hur, Jung-Mu;Lee, Bo-Young;Choi, Young-Ji;Kwon, Joong-Ho;Kim, Dong-Ho
    • Food Science and Preservation
    • /
    • v.15 no.3
    • /
    • pp.377-384
    • /
    • 2008
  • The gamma irradiation process was performed to prolong a shelf-life of peaches and the effects of a gamma irradiation on the nutritional, physiochemical and sensory characteristics of peaches were evaluated during a post-irradiation storage at $4^{\circ}C$ and $25^{\circ}C$. Nutritional, physiochemical and sensory characteristics of peaches were stable at 1 kGy of an irradiation, a recommended dose for fruits and vegetables by CODEX, and the viable cell counts of contaminated microorganisms were reduced by 2 decimal reduction, at this dose. After a 1-week storage at ambient condition, the microbiological quality of the 1 kGy irradiated peach was stable, while all the non-irradiated peaches were deteriorated Furthermore, cold storage enhanced the shelf-life of the gamma irradiated peach and the nutritional and physiochemical characteristics of the peaches were comparatively stable up to 6 weeks. Right after gamma irradiation, the sensory evaluation results were not different in any of the samples, and the sensory quality of the irradiated peaches was adequate for a 4-week storage at $4^{\circ}C$. Our results suggested that gamma irradiation at 1 kGy can be used to enhance the shelf-life of peach without a significant loss in the quality attributes, especially upon cold storage after radiation treatment.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.