• Title/Summary/Keyword: 생활하수 처리

Search Result 145, Processing Time 0.024 seconds

Application of Electrochemical Technology for Reusing Biologically Treated Water (생물학적 처리수 재이용을 위한 전기화학 기술의 적용)

  • Kang, Gu-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.453-458
    • /
    • 2008
  • Laboratory experiments were conducted to investigate disinfection as well as removal of color and residual organics from reclaimed municipal wastewater by electrochemical processes with Nb/Pt anode installed. RNO was rapidly bleached by OH$\cdot$ and the second order rate constants of RNO removal were $\frac{0.223l}{mg{\cdot}min}$, $\frac{1.679l}{mg{\cdot}min}$ and $\frac{2.322l}{mg{\cdot}min}$ with for 5 A, 10 A, and 15 A, respectively, with r$^2$ of > 96%. In batch electrochemical processes, after 15 min at currency of 15 A and initial pH of 5, 7,5 and 9, COD$_{Mn}$ was below 4 mg/L, color unit below 5 degree and general bacteria was not detected, the concentration of which are suitable for drinking water regulation. In the continuous electrochemical process, with HRT of 3.7$\sim$49.2 min, free chlorine were 0.2$\sim$0.7 mg/L, general bacteria was not detected, color unit below 5 degree and THMs was 0.017 mg/L. Therefore, electrochemical process with Nb/Pt anode was employed satisfactory to meet for reusing biologically treated water as well as disinfection.

Acute Toxicity on Daphnia magna and Photobacterium phosphoreum for synthetic Detergents (물벼룩과 형광성 박테리아를 이용한 합성세제의 급성독성평가)

  • 김태영;채수권;김건흥
    • Water for future
    • /
    • v.27 no.1
    • /
    • pp.69-77
    • /
    • 1994
  • As the standard of living improves, the amount of synthetic detergent consumption greatly increases. Detergents which are not treated in the sewer treatment processes, flow into rivers or waterstreams and accelerate the pollution of the surface water resources. Detergents contain lots of toxicants. And it is difficult to evaluate gross toxicity of each toxicant in thereceiving water. In the study, the acute toxicity of the synthetic detergents for home laundering and kitchen use were monitored with daphnia magna and photobacterium phosphoreum. Seven kinds of detergents were tested to evaluate the acute toxicity. The mean 24hr, 48hr-LC50 of the synthetic detergent for home laundering were 4.25%, 2.50% and these for kitchen use were 2.01%, 1.36% respectively. And the mean 5min, 15min-EC50 of the synthetic detergent for home laundering were 1.83%, 1.02%.

  • PDF

An Experimental Study on Water-Purification Properties of Concrete Using Effective Micro-Organisms (유용미생물을 이용한 콘크리트의 수질정화특성에 관한 실험적 연구)

  • Seo, Dae-Seuk;Jeon, Jin-yong;Kim, Jeong-Hwan;Kwon, Hyuk-Jun;Park, Seung-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.757-760
    • /
    • 2008
  • Recently, improvements in the standard of living in industrial area require establishment of a convenient residential environment in order to enhance the quality of living, To achieve such an environment, it is necessary to effectively reduce or prevent various environmental problems occurring in and around residential areas. In this study, We focused on the water-purification properties of concrete using effective micro-organisms. Such as SS, BOD, COD, T-P, T-N. The ability of the removal of SS, T-P, T-N in the test water is superior to concrete using effective micro-organisms. As a result, concrete using effective micro-organisms has sufficient performance of water-purification.

  • PDF

The impact of anthropogenic factors on changes in discharge and quality of water in the Hadano basin, Japan (인위적인 요인이 하천의 유량과 수질변화에 미친 영향 - 일본 하다노 분지를 사례 로 -)

  • ;Yang, Hea-Kun
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.3
    • /
    • pp.242-254
    • /
    • 1995
  • The Hadano Basin is located at a distance of about 70kms and 60kms from Tokyo and Yokohama and lies in the south-west part of the Kanto region in Japan. The basin area, which correspoends to the catchment of the Kaname River, is about areal size of 60.7$\textrm{km}^2$ and extends about length of 8kms in E-W direction and about width of 5kms in N-S direction (Fig.1). The Hadano basin is filled with thick pile of the alluvum from deposits composed of volcanic materials, mostly came from the Hakone Volcano and overlain by Fuji Volcanic ashes. Fluvial deposits form the good aquifer, therefore water resources of Handano City has been largely depending upon the eroundwater. Urbanization and industrialization of the basin has been rapid in the last thirty years, after activation of "Factory Attraction Policy of Hadano City" in 1956. Growth in population and number of factory due to urbanization changed the land-use pattern of the basin rapidly and increased the water demands. Therefore, Hadano City exploited a new source of water supply, and have introduced the prefectureal waterworks since 1976. On the other hand, the rapid urbanization has brought about the pollution of streams in the basin by domestic sewage and industrial waste water. Diffusion rate of sewerage systems in Hadano City is 38% in 1993. In ordcr to examine the impact of anthropogenic factors on river environments, the author took up the change of land-use and diffusion area of sewerage as parameters, and performed field surveys on water discharge and quality. The survey has been made at upstream and downstream of the main stream regularly per month, to get informati ons about the variation of discharge and water quality aiong the stream and its diurnal fluctuation. Annual variation has been analyzed based the data from Hadano City Office. The results are summarized as follows. 1. Stream discharge has been increasing by urbanization (Fig.3). Water quality (C $l^{-10}$ , N $H^{+}$$_{ 4}$-N, BOD) has been improving gradually after the application of sewerage service, yet water pollution load at the lower station has increased than that at the upper one because of the larger anthropogenic discharge volumes (Fig.4). 2. Corrclation coefficient of discharges between upper and lower was 0.81-0.92. Pollutant loads of the R. Kamame after the confluence with R. Kuzuha grew up by 2.4-3.7 times as compared with its upper reaches, and it increased to 3.7-6.9 times after the confluence with the R. Muro (Fig.5). 3. The changes of water quality along the stream can be divided into two groups (Fig.6a). First: water quality of the R. Kaname and R. Shijuhachisse is becoming worse towards the lower reaches because the water from branches are polluted. Second: water quality are improved in the lower where spring and small branch streams supply clear water, for example R. Mizunashi, R. Muro and R. Kuzuha. 4. Measured discharge at the upper station in the R. Shijuhachisse is 0.153㎥/sec, and about 55% of this is recharged until it reaches to the lower point. The R. Mizunashi has a discharge of 1.155㎥/sec at the upper point, is recharged 0.24㎥/sec until the midstream and groundwater spring 0.2㎥/sec at the lower reaches. R. Kuzuha recharged all the mountain runoff (0.2㎥/sec) at the upper reaches. The R. Muro is supplied by many springs and the estimated discharge of spring was 0.47㎥/sec (Fig.6b). 5. Diurmal variations in discharge and water quality are influenced clearly by domestic and industrial waste waters (Fig.7, 8).ed clearly by domestic and industrial waste waters (Fig.7, 8).

  • PDF

Changes of Nitrifying Bacteria Depending on the Presence and Absence of Organic Pollutant in Nak-Dong River (낙동강에서의 유기성 오염 유무에 따른 질화세균의 변화)

  • Jin, Seon-Yeong;Lee, Young-Ok
    • Korean Journal of Microbiology
    • /
    • v.49 no.2
    • /
    • pp.137-145
    • /
    • 2013
  • This study was performed at 2 sites of Nak-Dong River to investigate the changes of nitrifiers depending on the presence and absence of organic pollutants (due to the effluents of domestic wastewater treatment plant, WWTP). Conventional chemical parameters such as T-N, $NH_4$-N, $NO_2$-N, $NO_3$-N were measured and the quantitative nitrifiers at the 2 sites were analyzed comparatively by fluorescent in situ hybridization (FISH) with NSO190 and NIT3, after checking the presence of gene amoA of ammonia oxidizing bacteria (AOB) and 16S rDNA signature sequence for Nitrobacter sp. that belongs to nitrite oxidizing bacteria (NOB). Also ${\alpha}{\cdot}{\beta}{\cdot}{\gamma}$-Proteobacteria were detected using FISH to get a glimpse of the general bacterial community structure of the sites. Based on the distribution structure of the ${\alpha}{\cdot}{\beta}{\cdot}{\gamma}$-Proteobacteria and the measurement of nitrogen in different phases, it could be said that the site 2 was more polluted with organics than site 1. Corresponding to the above conclusion, the average numbers of AOB and NOB detected by NSO160 and NIT3, respectively, at site 2 [AOB, $9.3{\times}10^5$; NOB, $1.6{\times}10^6$ (cells/ml)] was more than those at site 1 [AOB, $7.8{\times}10^5$; NOB, $0.8{\times}10^6$ (cells/ml)] and also their ratios to total counts were higher at site 2 (AOB, 27%; NOB, 34%) than those at site 1 (AOB, 18%; NOB, 23%). Thus, it could be concluded that the nitrification at site 2 was more active due to continuous loading of organics from the effluents of domestic WWTP, compared to site 1 located closed to raw drinking water supply and subsequently less polluted with organics.

Effects of Municipal Sewage Sludge on Contents of Lead and Copper in Crop Plants. (경작지내(耕作地內) 도시하수(都市下水) Sludge 의 처리(處理)가 작물(作物)중 Cu 및 Pb 함량(含量)에 미치는 영향(影響))

  • Kim, Seong-Jo;Baek, Seung-Hwa;Chung, Dong-Jin
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.1
    • /
    • pp.9-19
    • /
    • 1992
  • To ditermine the accumulation of Cu and Pb in crops grown on Sludge-treated Soils, four crop plants, green onion(A Ilium ascalonicum L.), radish(Raphanus sativus L.), potato(Solanum tuberosum L.) and Chinese cabbage(Brassica pekinensis Rupr), were grown in greenhouses on soils treated with municipal sewage sludge at different levels of 0, 22.5, 45, and 90ton/ha as soil dry weight. The contant of heavy metals were analyzed in plant parts of the crop species and the statistical characteristics were investigated. The results were as follows: 1. Cu and Pb contents in experimental plants were increased in accordance with quanti of sludge applied. 2. Accumulation of Cu and Pb in leaves of plants was increased in order of radish

  • PDF

Development of the Inorganic Coagulants Using Red Mud and Evaluation of Its Coagulation Performance (적니를 이용한 무기응집제의 개발 및 응집성능 평가)

  • Lee, Jae-Rok;Hwang, In-Gook;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.8 no.2
    • /
    • pp.85-92
    • /
    • 2002
  • Red mud is generated as a by-product during the production of aluminum hydroxide from bauxite ore. In this study the red mud coagulants were prepared by reacting 100 ml of 5 M $H_2SO_4$ solution with 10g of red mud at $85^{\circ}C$ or by reacting 100ml of 9M HCl solution with 10g of red mud at $25^{\circ}C$. The prepared red mud coagulants were tested for their coagulation performance of pollutants in the municipal and industrial wastewater. In addition, the coagulation performance was compared with that of a commercially available coagulant ($FeCl_3$). As a result, the red mud coagulants were found to have a good removal efficiency of pollutants in the municipal wastewater (turbidity, phosphate phosphorus) and in the plating wastewater (turbidity, $Pb^{2+}$, $Cd^{2+}$, $Cu^{2+}$, $Zn^{2+}$, $Cr^{3+}$). In the experiment to remove COD in the petrochemical wastewater, the COD removal efficiency by the red mud coagulants was a little poor, but it was better than that by $FeCl_3$.

  • PDF

A study on the Livestock nonpoint source runoff characteristics and Load Calculation (축산계 비점오염원 유출 특성 및 부하량 산정에 관한 연구)

  • Ryu, Jeha;Yoon, Chun Gyung;Cho, MoonSoo;Lee, HyoJun;Lee, BoMi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.574-574
    • /
    • 2016
  • 유역으로 유입되는 오염물질의 발생원은 점오염원과 비점오염원으로 구분할 수 있으며 점오염원의 경우 생활하수, 산업폐수, 그리고 축산폐수에 대해 처리시설 확충 및 기술개발을 통해 관리하고 있다. 비점오염원에서의 오염물질 유출은 토지이용, 강우, 불특정적인 오염물질 투입상태 등에 따라 다르며, 지역적 특성에 영향을 받기 때문에 불확실성이 고려되어야 한다. 특히 농촌지역에서의 비점오염은 접근이 어렵고 관리주체가 모호하여 좀처럼 규명되지 않았으며, 전국적으로 그 영향이 정량화되지 않아 실질적인 관리 및 대책마련에 어려움이 있었다. 특히, 가축분뇨의 발생으로부터 처리, 자원화에 이르기까지 각 관리체계에 있어서 축산비점오염의 배출경로와 수계오염부하량, 수질환경 영향을 정밀하게 분석하여 향후 대책마련을 위한 기초자료를 확보할 필요가 있다. 또한 전국적으로 비점오염이 수계에 미치는 영향과, 그 중 축산비점오염의 영향을 면밀히 분석하여 향후 정책 및 제도개선을 위한 과학적 기초자료로서 활용할 필요가 있다. 따라서 본 연구에서는 축산 밀집 지역을 대상으로 오염원 조사를 통해 강우시 비점오염 모니터링 지점을 선정 하였으며, 년5회씩 강우 모니터링을 하여 기초데이터를 축적 하였다. 대상지역은 강원도 횡성군에 위치한 일리천 유역이며 농가 수는 총 90개의 농가가 위치하고 있는데 그 중 돼지 1,467마리, 한우 1,957마리, 젖소 581마리, 개 2,880마리, 닭 75,000마리, 사슴 4마리로 조사되었다. 대상유역을 대상으로 배출부하량을 조사한 결과 BOD 배출부하량은 총 509.3 kg/day, T-N 배출부하량은 총 331.5 kg/day, T-P 배출부하량은 총 28.3 kg/day로 조사되었다. 유출특성을 파악하기 위하여 유량가중평균농도(Event Mean Concentration, EMC)를 산정한 결과 BOD의 경우 MW-4에서 1.2 mg/L - 7.2 mg/L, MW-5에서 0.8 mg/L - 6.3 mg/L, MW-7에서 0.7 mg/L - 5.2 mg/L의 범위를 보였다. T-N의 경우 MW-4에서 1.426 mg/L - 5.321 mg/L, MW-5에서 1.205 mg/L - 4.27 mg/L, MW-7에서 0.989 mg/L - 3.859 mg/L의 범위를 보였다. T-P의 경우 MW-4에서 0.245 mg/L - 0.632 mg/L, MW-5에서 0.236 mg/L - 0.596 mg/L, MW-7에서 0.213 mg/L - 0.521 mg/L의 범위를 보였다. 본 연구에서 EMC를 산정한 방법은 평시 수질 및 유량을 정하는 기준에 따라 값이 많이 달라질 수 있다. 따라서 합리적으로 평시 부하량을 제외하고 강우시의 영향을 파악할 수 있는 EMC 산정방법에 대한 추가적인 고찰이 필요할 것으로 사료된다.

  • PDF

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.

Effect on Digestion Efficiency by Adding Microbial Agent in Mesophilic Two-stage Anaerobic Digester (중온2단혐기성소화조에 미생물제재 주입시 소화효율에 미치는 영향)

  • Jung, Byung-Gil;Kim, Seok-Soon;Kang, Dong-Hyo;Sung, Nak-Chang;Choi, Seung-Ho;Lee, Hee-Pom
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.3
    • /
    • pp.75-86
    • /
    • 2003
  • In the near future, the capacity of conventional anaerobic digester is thought to be insufficient because of the increase of the total solids from expansion of intercepting sewer, sewage quantity and direct input of night soil from near apartment districts. The objectives of this study was to investigate the improvement of digestion efficiency using microbial agent(Bio-dh). The system was a pilot-scale, two-staged, anaerobic sludge digestion system. The first-stage digester was heated and mixed. The agitation velocity of the first-stage digester was 120rpm. The second-stage digester was neither heated nor mixed. The Digestion temperature was kept at $35{\pm}1^{\circ}C$ The detention time of digester was 19 days. The dosage of sewage sludge and microbial agent were $0.65m^3/day$ and $0.5{\ell}/day$, respectively. The experiments was run for 25days. Three times a week, $COD_{Mn}$ and SS of effluent, TS, VS, and biogas production rate were measured. Temperature, pH, and alkalinity were measured daily. The results were as follows ; Without microbial agent, digestion efficiencies ranged 46.0%~50.9%(mean=48.6%), with microbial agent(Bio-dh), digestion efficiencies ranged 52.8%~57.3%(mean=54.2%). Consequently, microbial agent(Bio-dh) increased the sludge digestion efficiency about 12%. Also, Without microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 1,639mg/L, 4,888mg/L respectively. With microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 859mg/L, 2,405mg/L respectively. Consequently, microbial agent(Bio-dh) increased the removal efficiency of $COD_{Mn}$ and SS about 47.6% and 50.8%, respectively.

  • PDF