• Title/Summary/Keyword: 상층부

Search Result 329, Processing Time 0.032 seconds

Uncertainty Analysis of the Optical Smoke Density Measurement through the Doorway in a Compartment Fire (구획화재의 출입구를 통한 광학적 연기밀도 측정의 불확실성 해석)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-79
    • /
    • 2013
  • The present study measured the light transmission to quantify the smoke density(smoke mass concentration) through the doorway in a compartment fire and performed the uncertainty analysis to evaluate the reliability of the measurement technique. The optical light extinction method based on Bourguer's law was applied to estimate the smoke density of doorway exhausting smoke flow in upper layer of a compartment for methane gas fires. The measurement uncertainty of the light extinction measurement was evaluated for the light transmittance, path length, and specific mass extinction coefficient and the expanded uncertainty was estimated about 20% with confidence level of 95%. The mean smoke density through the doorway for the methane fire was calculated for quasi-steady fire and the smoke density linearly increased as the GER increased.

Numerical Study on the Validity of Scaling Law for Compartment Fires (구획 화재의 상사 법칙 유효성에 관한 수치해석 연구)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.29-34
    • /
    • 2014
  • In this study, to assess the validity of scaling law which was based on the ventilation factor and utilized in fields of compartment fires, numerical simulations were conducted on full- and 2/5 reduced-scale compartment fires using FDS and simulation results were compared with the previously published experimental data. The numerical modeling used in this study was verified by comparing the predicted temperature at several points of the upper layer with the experiment data. Temperature and concentration distribution inside of compartments and velocity profile at door of compartment are analyzed to assess the validity of scaling law. Comparison between the predicted results on the full- and reduced-scale compartments shows good agreements on the inner compartment flow patterns, outflowing flame patterns from the compartments, and vertical temperature distributions.

FPI Array-Based Infrared Micro-Spectrometer for Multi-Gases Detection (다중가스 검출을 위한 FPI 어레이 기반 적외선 마이크로스펙트로미터)

  • Kang, Hyun-Oh;Zhiguo, Zhao;Lee, June-Kyoo;Jung, Ho;Kim, Hak-Rin;Kong, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1547_1548
    • /
    • 2009
  • 제안된 Fabry-Perot Interferometer (FPI) 어레이 기반 IR 스펙트로미터는 상층부에 FPI 어레이와 하단에 $V_2O_5$ 볼로미터 IR 적외선 센서어레이로 크게 두 부분으로 구성된다. 이 구조에서 다양한 FPI 공진 캐비티의 두께에 의해 특정 공진 파장이 선택되어 진다. 그리고 각각의 볼로미터 IR 디텍터는 IR 파장에 상응하는 투과도를 감지해낸다. 다양한 박막 필터 시뮬레이션 결과를 통해 제작된 FPI 어레이 기반 IR 스펙트로미터는 $3{\sim}5{\mu}m$의 적외선 파장대역에서 흡수 스펙트럼을 가지는 $CH_4$, $CO_2$, $N_2O$, CO 가스 검출을 위해 다층 박막 FPI 층의 다층 박막 FPI 층의 투과율을 높였다.

  • PDF

A Study on the Optimum Mix Proportion for Early Strength of Concrete in the Upper Layers of High Rise Building (Part II - 80MPa) (초고층 빌딩용 상층부 콘크리트의 조기강도 확보를 위한 최적배합 도출에 관한 연구 (Part II - 80MPa를 중심으로))

  • Jeon, In-Ki;Park, Yong-Kyu;Lee, Joo-Hun;Choi, Myung-Hwa;Yoon, Gi-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.325-328
    • /
    • 2008
  • Recently increasing interest in high-rise building around the world for more than 100 floor, the trend is the increasing use of high-strength and high-flowable concrete so as of productivity improvements and cost savings to improve the performance of the early strength development. This study is to reach the optimal combination by reviewing the performance of high-rise building which is required. The results, lower the ratio of W/B was an increase in compressive strength and early strength in the use of admixture decreased in the combination of higher replacement ratio of admixture.

  • PDF

Noise and Rooms Acoustic Control in Multi-Purpose Space (다목적 공간의 소음 및 실내음향 제어)

  • Jeong, Jeong-Ho;Kim, Jung-Joong;Cho, Chang-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.42-45
    • /
    • 2008
  • 다목적 공간 및 공연장은 공연 또는 강연을 위한 공간뿐만 아니라 상점, 식당 및 체육 공간 등 다양한 용도의 공간이 인접되고 있다. 다양한 공간이 인접할 경우 기존의 다목적 공연장에서는 발생하지 않았던 다양한 소음 진동 문제들이 발생한다. 본 연구는 강연 및 공연을 위한 다목적 공간 상부에 식당 및 체육 시설로 활용되는 공간이 배치되어 바닥충격음 문제가 발생할 가능성이 있었다. 바닥충격음의 강당으로의 전달을 차단하기 위하여 기본 구조체에 대한 바닥충격음 차단성능을 측정하여 적절한 저감 대책을 수립하였다. 저감대책으로는 상층부 철골 슬래브와 강당의 철골 구조의 구조적 분리, 유연한 마감재 적용, 슬래브로의 충격진동 차단을 위한 제진재 적용, 이중천장 구조 및 천장내부 흡음구조 형성 등의 종합적인 대책을 수립하였다. 이를 통해 경량충격음 및 중량충격음을 효율적으로 차단하였다. 또한 강당 공간은 강연 및 집회의 공간으로 활용될 수 있도록 하기 위하여 적절한 잔향시간 및 음성 명료도 확보가 필요하다. 플러터 에코, 과도한 잔향시간, 음의 사각지대 등을 최소화하기 위하여 측벽 형태 개선, 천장 반사판 형태를 개선하였다. 또한 측벽에서 진동 등의 영향으로 발생되는 떨림현상을 억제하기 위하여 측벽 내부를 흡음재로 충전하는 등의 대책을 수립하여 적용하였다.

  • PDF

An experimental study on the performance of silencers for exhaust merchant ships considering air flow velocity (관내 유속을 고려한 상선의 배기관용 소음기의 성능실험연구)

  • Jae-Kwang Eom;Sa-Soo Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.1
    • /
    • pp.108-115
    • /
    • 2001
  • The noise level of the navigation bridge as well as topside of the superstructure is dominated by the exhaust gas noise of the high-powered main engine and generator engine of special purpose vessels. In the case of the noise radiated from the top of the funnel. the exhaust pipe can be fitted with a silencer to reduce the propagated noise level. This paper is prepared based on an experimental performance test results of the silencers for generator-engine exhaust gas noise with consideration of air velocity. Two silencers were examined to check the performance of noise reduction in cases of air velocity 0m/s and 32m/s. In the sound reduction test, 400mm and 600mm diameter pipe ducts equipped with an axial fan were used as exhaust gas pipe system in the actual ship. The test procedure and results are presented in detail.

  • PDF

A Full-scale Fire Test of an Apartment House (공동주택 실물화재 실험)

  • Kim, Myung-Bae;Han, Yong-Shik;Choi, Byung-Il;Do, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2009
  • To research about the fire spread in Korean apartment house, a full-scale fire test in a four-story apartment was executed. The fire started at the third floor, and originated from overheated cooking oil in the kitchen. The apartment included all combustibles in general house. Through measuring temperature, measuring the concentration of oxygen and observing, we investigated the fire spread inside the apartment house. As a result, we got the data of the time needed for the initiation of fire, the time for fire to spread into each area in the house, and the time required until flash-over was seen. Also we grasped the understanding of the fire spread to the upper floor.

Temperature Inversion off Wasaka Bay in the East Sea, June of 1995 and 1996

  • Lee Chung-Il;Cho Kyu-Dae;Yun Jong-Hwui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.55-59
    • /
    • 2004
  • Temperature inversion off Wasaka Bay in the East Sea was studied using data measured on a CREAMS cruise in June of 1995 and 1996. Temperature inversion occurred mainly at the upper layer of the thermocline at a depth of no more than 20 m and around the thermal front between the TWC and the coastal waters of Japan. At some stations. temperature inversion had an influence un density inversion, while, in some other stations, high salinity water prevented density inversion.

  • PDF

FDS Simulation and Validation on the Under-Ventilated Compartment Fires (환기부족 구획화재에 대한 FDS 해석 및 검증)

  • Ko, Gwon-Hyun;Kim, Sung-Chan;Hamins, A.;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.103-109
    • /
    • 2009
  • In this study, fire simulations on the under-ventilated compartment fires have been conducted using the Fire Dynamics Simulator (FDS Ver. 5.2) and its prediction performance on the thermal and combustion chemical characteristics has been discussed. The temperature and chemical species concentrations in the upper layer of methane, heptane, and toluene fires located in a 2/5 scale compartment based on the ISO-9705 standard room are predicted and compared with the previously published experimental data. The results showed that the FDS simulations reproduced well the temperature of the ceiling and the mixture fraction in the upper layer under the well-ventilation conditions. For the under-ventilated fires, which were taken place due to the insufficient oxygen entrainment, the prediction by the FDS significantly under-estimated the production of carbon monoxide and soot compared to the experimental data.

A Study on the Characteristics of Heat Flux on the Floor in a Compartment Fire (화재실 화재에서 바닥면의 열유속 특성연구)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.231-234
    • /
    • 2010
  • 본 연구는 화재조건에 따른 화재실 바닥면에서의 열유속특성을 파악하기 위해 ISO-9705 표준화재실의 40% 축소모형공간에 대하여 화재실험을 수행하고 화재성상에 따른 열유속변화와 공간적 분포를 분석한다. 또한 모형실험에서 계측된 열유속을 Scaling Law를 적용하여 실규모 크기의 결과로 환산하고 이를 기존의 다른 연구결과와 비교분석함으로써 화재발생으로 인한 공간내 열유속의 축소법칙의 적용성을 파악하고자 한다. 실험에 사용된 연료는 천연가스, 메탄올, 에탄올, 헵탄, 톨로엔, 폴리스틸렌등이며 모형실험의 최대발열량은 450 kW 정도로 실규모로 환산시 약 4.4 MW이다. 실험결과 화재실바닥면의 열유속은 연층의 온도와 연료의 종류에 따라 차이를 보였으나 측정위치별 차이는 크지 않았으며 Scaling Law를 적용한 결과 화재실 상층부 온도가 약 $500{\sim}600^{\circ}C$ 정도에서 바닥면의 열유속은 약 $20kW/m^2$ 정도로 기존연구와 유사한 경향을 보였다. 본 연구는 화재공간 내 열유속 측정을 통해 전실화재로의 화재성장을 파악하고 화재실내부의 열적특성을 분석하기 위한 기초적인 자료를 제공하고자 한다.

  • PDF