• Title/Summary/Keyword: 상대표준편차

Search Result 311, Processing Time 0.035 seconds

The Study of Land Surface Change Detection Using Long-Term SPOT/VEGETATION (장기간 SPOT/VEGETATION 정규화 식생지수를 이용한 지면 변화 탐지 개선에 관한 연구)

  • Yeom, Jong-Min;Han, Kyung-Soo;Kim, In-Hwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.4
    • /
    • pp.111-124
    • /
    • 2010
  • To monitor the environment of land surface change is considered as an important research field since those parameters are related with land use, climate change, meteorological study, agriculture modulation, surface energy balance, and surface environment system. For the change detection, many different methods have been presented for distributing more detailed information with various tools from ground based measurement to satellite multi-spectral sensor. Recently, using high resolution satellite data is considered the most efficient way to monitor extensive land environmental system especially for higher spatial and temporal resolution. In this study, we use two different spatial resolution satellites; the one is SPOT/VEGETATION with 1 km spatial resolution to detect coarse resolution of the area change and determine objective threshold. The other is Landsat satellite having high resolution to figure out detailed land environmental change. According to their spatial resolution, they show different observation characteristics such as repeat cycle, and the global coverage. By correlating two kinds of satellites, we can detect land surface change from mid resolution to high resolution. The K-mean clustering algorithm is applied to detect changed area with two different temporal images. When using solar spectral band, there are complicate surface reflectance scattering characteristics which make surface change detection difficult. That effect would be leading serious problems when interpreting surface characteristics. For example, in spite of constant their own surface reflectance value, it could be changed according to solar, and sensor relative observation location. To reduce those affects, in this study, long-term Normalized Difference Vegetation Index (NDVI) with solar spectral channels performed for atmospheric and bi-directional correction from SPOT/VEGETATION data are utilized to offer objective threshold value for detecting land surface change, since that NDVI has less sensitivity for solar geometry than solar channel. The surface change detection based on long-term NDVI shows improved results than when only using Landsat.

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

Distributional Characteristics of Microcrack in Tertiary Crystalline Tuff from Northeastern Gyeongsang Basin (경상분지 북동부의 제3기 결정질 응회암에서 발달하는 미세균열의 분포특성)

  • Park, Deok-Won;Lee, Chang-Bum
    • The Journal of the Petrological Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.315-336
    • /
    • 2009
  • We have studied the orientational characteristics of microcrack frequency, it's length and density in Tertiary crystalline tuff from the northeastern part of the Gyeongsang Basin. 134 sets of microcracks on horizontal surfaces of 3 rock samples from Heunghae-eup were distinguished by enlarged photomicrographs of the thin sections. The variability in patterns among microcrack length-frequency histograms for three rock samples from different altitudes were derived. The pattern of histograms changes progressively from negative exponential form to log-normal form in proportion to altitude. The distribution pattern for rock sample no.1 from lower altitude shows the broad length distribution characterized by higher mean and median, and higher standard deviation. Meanwhile, this distribution pattern corresponds with characteristics of joint length distribution in sedimentary rocks of the lower part of the Gyeongsang Supergroup. The occurrence frequency of shorter microcracks increases toward both NW and NE directions from the $N0{\sim}10^{\circ}W$, with the dominant direction of $N80{\sim}90^{\circ}W$ and $N80{\sim}90^{\circ}E$, respectively. This distribution pattern represents the relative differences in formation timing among microcrack sets and the result of the new initiation of shorter microcracks. Meanwhile, the longest microcracks within $N60{\sim}70^{\circ}W$($L_{max}$:1.18 mm) and $N0{\sim}10^{\circ}W$($L_{max}$:0.80 mm) directions are seen, but this kind of microcracks are very limited in number. Whole domain of the directional angle($\theta$)-frequency(N), length(L) and density($\rho$) chart can be divided into five sections in terms of phases of the distribution of related curves. From the distribution chart, density curve shows five distinct peaks in the WNW-ESE($N70{\sim}80^{\circ}W$), NS~NNE-SSW($N0{\sim}10^{\circ}W$, $N10{\sim}20^{\circ}E$), ENE-WSW($N50{\sim}60^{\circ}E$), and nearly EW($N80{\sim}90^{\circ}E$) directions, respectively. Especially, main directions of faults correspond with the directional angle showing high density. Consequently, these distribution patterns of density curve reflect the representative maximum principal stress orientations suggested in previous studies.

Comparison and validation of rutin and quercetin contents according to the extraction method of tartary Buckwheat (Fagopyrum tataricum Gaertn.) (쓴메밀 종자의 추출방법에 따른 루틴 및 퀘세틴 함량 비교)

  • Kim, Su Jeong;Sohn, Hwang Bae;Kim, Geum Hee;Lee, Yu Young;Hong, Su Young;Kim, Ki Deog;Nam, Jeong Hwan;Chang, Dong Chil;Suh, Jong Taek;Koo, Bon Cheol;Kim, Yul Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.258-264
    • /
    • 2017
  • The stability and accuracy of ultra-performance liquid chromatography (UPLC) used for evaluating the contents of rutin and quercetin in tartary buckwheat (Fagopyrum tataricum Gaertn.) seeds extracted by seven different extraction methods were determined. The seven extraction methods were reflux extraction (RE), ultra-sonification extraction (UE), stirrer extraction (SE), RE after UE (UE+RE), RE after SE (SE+RE), UE after SE (SE+UE), and RE with UE after SE (SE+UE+RE). Among the seven extraction methods used, RE yielded comparatively higher contents of rutin (2,277 mg/ 100 g) and quercetin (158 mg/100 g) than those yielded by other six extraction methods. The intra-day repeatability and inter-day precision of RE was 0.4-3.2% considering relative standard deviation (RSD), while accuracy was 88.8-102.4%. Therefore, RE with UPLC would be a rapid, accurate, and stable method for analyzing rutin and quercetin contents in tartary buckwheat.

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

Simultaneous Analysis Method of BPA, BPF, BADGE, BFDGE and Their Degradation Products in Canned Foods and Food Simulants by HPLC (HPLC를 이용한 캔 식품 및 식품 유사용매 중 BPA, BPF, BADGE, BFDGE 및 분해산물의 동시분석법)

  • Choi, Jae-Chun;Kyung, Suk-Hun;Lee, Gun-Tack;Lee, Kwang-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.174-179
    • /
    • 2002
  • A simple and sensitive analysis method based on reverse phase (RP) HPCL with flourescence detector was developed for simultaneous determination of bisphenol A (BPA), bisphenol F (BPF), bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE), and their degradation products, $BADGE{\cdot}H_2O$, $BADGE{\cdot}2H_2O$, $BFDGE{\cdot}H_2O$, $BFDGE{\cdot}2H_2O$, $BADGE{\cdot}HCl{\cdot}H_2O$, $BADGE{\cdot}HCl$, $BADGE{\cdot}2HCl$, $BFDGE{\cdot}HCl{\cdot}H_2O$, $BFDGE{\cdot}HCl$ and $BFDGE{\cdot}2HCl$, which were hydrolyzed and chlorinated forms of BADGE and BFDGE, in canned foods and food simulants. These compounds were identified by GC/MSD with $MSTFA-NH_4I-DTE$ derivatization. Recovery study was performed at each 100 ng/mL levels of BPA, BPF, BADGE and BFDGE added to canned foods and food simulants. This method was resulted in recovery of $90{\sim}114%$ with relative standard deviation of $4.1{\sim}7.0%$, detection limits of $6{\sim}11$ ng/mL and quantitation limits of $12{\sim}18\;ng/mL$. Calibration curves were linear with correlatin coefficients of 0.997 for BPF, 0.996 for BPA, 0.9987 for BFDGE, and 0.9989 for BADGE.

Middle School Home Economics Teachers Perspective about Home Economics Curriculum and Housing Education Value (중학교 가정과 교사의 교육과정 관점과 주거교육 가치관)

  • Lee, Yeon-Jung;Cho, Jae-Soon;Chae, Jung-Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.19 no.4
    • /
    • pp.219-232
    • /
    • 2007
  • The purpose of this study was to investigate middle school Home Economics(HE) teachers' perspective on HE curriculum, their Housing Education Value in Home Economics, and then find out correlations between them. Questionnaire was administered to HE teachers who had experienced teaching Housing content over the whole country through e-mail or face-to-face meeting. 207 data collected from the responses were finally analyzed statistically with mean, standard deviation, percentage, T-test, one-way ANOVA, post verification(Scheffe) and Pearson correlation by using SPSS/WIN(ver. 10.0) program. The results of the study were as follows: First, about Home Economics teachers' perspective on HE curriculum, the existential perspective was the highest, followed by the structural perspective and the traditional perspective. Second, about their perspectives on Housing Education Value, generally the most important thing they value was an aspect of ecology, followed by an aspect of economics, an aspect of Socio-Psychology, an aspect of space planning, an aspect of local environment, an aspect of career education, an aspect of culture, an aspect of housing management and an aspect of housing policy. Third, about the relation between their perspectives on curriculum and Housing Education Value, among 9 kinds of Housing Education Value, the traditional perspective was low associated with only housing management value including to Housing Education Value. However, the existential perspective and the structural perspective tended to be moderately or low associated with most of the values including to Housing Education Value.

  • PDF

Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla (3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.120-128
    • /
    • 2002
  • To investigate differences between the metabolic ratios of normal controls and brain tumors such as astrocytomas and glioblastoma multiforme (GM) by proton MR spectroscopy (MRS) at 37 high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16$\pm$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of glioblastoma multiforme was significantly higher than that of astrocytomas (P=0.001). Lactate was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

Influence on Intra-limb Coordination in Individuals Wearing a Knee Extension Constraint Brace during Walking (무릎 신전 제한형 보조기 착용이 보행 시 하지 내 협응에 미치는 영향)

  • Chang, Yoonhee;Jeong, Bora;Kang, Sungjae;Ryu, Jeicheong;Kim, Gyu Seok;Mun, Museong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.207-214
    • /
    • 2016
  • The aim of this study was to evaluate Influence on intra-limb coordination in individuals wearing knee brace during walking. Seven healthy male adults ($32.3{\pm}2.7$ years old, $175.2{\pm}3.8cm$, $76.2{\pm}8.7kg$) participated. They wore knee brace or didn't wear any knee brace and were asked to walk along a 10 m long walkway. Spatiotemporal parameters, angles of the lower limbs, and intra-limb continuous relative phase (CRP) were measured and calculated. No differences of spatiotemporal parameters were shown (all p > 0.05). There were no changes in the angle and its range of motion (ROM) in the hip for the subjects as wearing knee brace, while ROM ($65.5{\pm}3.7^{\circ}$ vs. $60.5{\pm}3.5^{\circ}$, p < 0.05) of the angle and maximum flexion angles (stance: $31.9{\pm}4.6$ vs. $25.6{\pm}5.5$, swing: $76.7{\pm}3.1$ vs. $68.9{\pm}3.4$, all p < 0.05) in the knee significantly decreased. No changes in ROM of angle in the ankle were shown, whereas maximum dorsiflexion decreased ($22.4{\pm}2.6$ vs. $19.2{\pm}2.1$, p < 0.05) and maximum plantarflexion increased ($9.5{\pm}3.0$ vs. $15.7{\pm}2.2$, p<0.05). There were no changes in most of CRP between joints. CRP between the hip and knee joints decreased ($93.0{\pm}7.8$ vs, $84.7{\pm}4.9$, p < 0.05). Most of CRP standard deviation increased (between the hip and ankle joint during swing: $25.1{\pm}6.7$ vs. $32.4{\pm}1.9$, between the knee and ankle joint during stance: $46.0{\pm}12.9$ vs. $80.1{\pm}31.1$, between the knee and ankle joint during swing: $34.5{\pm}4.1$ vs. $37.6{\pm}3.1$, all p < 0.05). These results indicated that wearing knee brace affected joint angle and intra-limb coordination, but less affected gait features.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.