• 제목/요약/키워드: 상대식 승강장

검색결과 11건 처리시간 0.026초

열차 운행에 따른 상대식 승강장에서 지하철 승강장 스크린 도어 풍압해석 (THE PRESSURE-TRANSIENT ANALYSIS ON THE PLATFORM SCREEN DOORS OF THE SIDE PLATFORMS IN A SUBWAY STATION WITH VARIOUS OPERATING CONDITIONS)

  • 이명성;안혁진;원찬식;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.283-289
    • /
    • 2008
  • The pressure-transient on platform screen doors in side platforms caused by passing trains with various operating conditions have been investigated numerically. The transient compressible three-dimensional flow simulations are performed with actual operating conditions of two trains by adopting moving mesh technique. To achieve more realistic results, the detailed shape of train and the subway station including tunnels connecting the adjacent stations are represented in the computational domain. Numerical analyses are carried out for cases considering arriving/passing/departing train with or without train stopped on the opposite track, and both trains on the move in opposite direction. From the numerical results, the maximum pressure on the platform screen doors, which is predicted in the case of two passing trains, satisfied the design standards for similar stations.

  • PDF

열차 운행에 따른 상대식 승강장에서 지하철 승강장 스크린 도어 풍압해석 (THE PRESSURE-TRANSIENT ANALYSIS ON THE PLATFORM SCREEN DOORS OF THE SIDE PLATFORMS IN A SUBWAY STATION WITH VARIOUS OPERATING CONDITIONS)

  • 이명성;안혁진;원찬식;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.283-289
    • /
    • 2008
  • The pressure-transient on platform screen doors in side platforms caused by passing trains with various operating conditions have been investigated numerically. The transient compressible three-dimensional flow simulations are performed with actual operating conditions of two trains by adopting moving mesh technique. To achieve more realistic results, the detailed shape of train and the subway station including tunnels connecting the adjacent stations are represented in the computational domain. Numerical analyses are carried out for cases considering arriving/passing/departing train with or without train stopped on the opposite track, and both trains on the move in opposite direction. From the numerical results, the maximum pressure on the platform screen doors, which is predicted in the case of two passing trains, satisfied the design standards for similar stations.

  • PDF

지하철 승강장 화재시 연기의 전파속도에 따른 승강장 형태별 피난시간 비교·분석 연구 (A study of comparative of evacuation time by platform type according to the propagation speed of smoke in subway platform fire)

  • 김진수;이동호
    • 한국터널지하공간학회 논문집
    • /
    • 제19권4호
    • /
    • pp.577-588
    • /
    • 2017
  • 화재와 같은 상황에서 인간의 피난 행동을 실험하는 것은 경제적으로나 윤리적으로 많은 제약이 따른다. 때문에 인간의 피난행동은 기존에 보고 연구된 피난 행동을 바탕으로 시뮬레이션 되고 있으며 최근에는 컴퓨터 성능의 발전으로 현실에 가까운 모델들이 연구될 수 있는 기반이 마련되었다. 본 연구에서는 화재시 인간의 행동특성과 연기 전파를 모델링하여 지하철 승강장 내에서의 피난시간을 분석하였다. 또한 지하철 역사 승강장의 형태를 계단 위치에 따라 구분하여 각 승강장별 피난시간을 비교함으로써 피난효율을 검토하였다. 그 결과 상대식 승강장은 섬식 승강장에 비해 평균 36.82%의 피난시간이 더 소요되며, 승강장 내의 계단 위치에 따라서는 승강장 중앙에서 화재가 발생하는 경우 상대식 승강장이 210초, 섬식 승강장이 186초로 승강장 2/5지점과 4/5지점에 계단이 위치하는 형태가 피난 측면에서 가장 우수한 것으로 나타났다.

상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석 (WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STAT10N CAUSED BY PASSING TRAINS)

  • 이명성;이상혁;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.64-67
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is obtained with actual operational condition of subway train and the moving mesh technique is adopted considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel of platform are included in a computational domain and detailed shape of train is also modeled Numerical analyses were conducted on five operational condition which are different velocity variation of subway train, existence of stationary train and passing each other trains. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation was found to be satisfactory to various foreign standards.

  • PDF

상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석 (WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STATION CAUSED BY PASSING TRAINS)

  • 이명성;이상혁;허남건
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.1-6
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is used with actual operational condition of subway train by adopting the moving mesh technique considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel connecting the stations are included in a computational domain with modeling the detailed shape of the train. Numerical analyses are conducted on five operational conditions which include the variation of the train speed, case with or without the train stopped in the other track, and case for two trains passing each other inside the station. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation for the cases considered in the present study is found to be satisfactory to various foreign standards.

대심도 지하철 승강장의 종류별 연기전파특성 비교고찰 (THE COMPARISON ON THE CHARACTERISTIC OF THE FIRE DRIVEN SMOKE-FLOW FOR THE PLATFORM TYPES IN THE DEEPLY UNDERGROUND SUBWAY STATION)

  • 김학범;장용준;이덕희;정우성;황현배
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.505-507
    • /
    • 2010
  • 본 논문에서는 대심도 지하철역사의 승강장 종류에 따라 화재시 연기의 전파특성을 비교하였다. 본 연구에서 비교 대상역사로서 상대식 승강장은 서울 숭실대입구역사(47m)로, 섬식은 부산 만덕지하역사(65m)를 선정하여 각 역사에 대하여 화재전산모사를 수행하였다. 해석을 통하여 화재의 연기전파특성을 파악하였으며, 그 결과를 이용하여 각 승강장 종류별로 대심도 지하역사의 방재대책을 세우고자 한다.

  • PDF

지하철 승강장 및 환승정거장 유형에 따른 이용자 만족도 분석 (Analysis of User Satisfaction by Types of Subway Platforms and Transit Stations)

  • 김황배
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.437-445
    • /
    • 2015
  • 지하철 만족도에 큰 영향을 미치는 시설물의 배치, 정보안내의 경우 지하철 승강장 및 환승정거장의 유형에 따라 달라지게 되나, 현재 해당 항목에 대한 연구는 미비한 실정이다. 본 연구는 이러한 관점에서 출발하여 IPA 분석 기법을 활용하여 승강장 및 환승정거장 유형에 따른 이동시설 및 환승편의시설, 정보안내의 만족도간 중요도를 분석하는 것을 목적으로 한다. 이를 위해 수도권 도시철도 환승역사 15개를 대상으로 승강장 및 환승정거장 유형에 따라 분류하고, 승강장 및 환승정거장 유형이 동일함에 따라 이용자간 중요도 및 만족도 차이, 개선항목 등을 분석하였다. 본 연구의 분석 결과 동선교차가 많이 발생되는 승강장 유형(상대식 승강장)과 환승정거장 유형(+, L, T자형)으로 지하철역을 설계하는 경우 이동편의시설 및 정보안내표지의 적정한 위치 선정이 중요함을 도출하였다. 이러한 분석 결과는 향후 이용자의 불편이 최소화할 수 있는 방향으로 신규 역사 설계 및 기존 역사 개선시 활용이 가능하며, 승강장 및 환승정거장 유형에 따라 우선적으로 개선해야 하는 항목 도출로 지하철 개선비용 효율성 증대 가능할 것으로 판단된다.

지하철 상대식 승강장의 제연운전모드 실효성에 관한 연구 (A Study for a Effectiveness of Smoke Control Operation Mode for a Subway with Separate Platform)

  • 이동호
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.24-29
    • /
    • 2005
  • This study aim to derive the operation method of a comprehensive ventilation system which is capable of providing passengers with safe exit paths from platforms in onboard The situations. The airflow distributions in subway platforms under 13 types of tunnel vent system for a double track stop condition was calculated and having analyzed diffusion behaviors of smoke and heat exhaust in such states by performing 13 kinds of different ventilation scenarios by using a 3-D Fire Dynamic Simulation (FDS) simulation model to clarify the safety evaluation for the heat and smoke exhaust on subway fire events.

지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구(II) - 수치적 접근 - (Experimental and Numerical Studies on Heat/Smoke Behavior due to a Fire on Underground Subway Platform (II) - Numerical Approach -)

  • 장희철;김태국;박원희;김동현
    • 한국화재소방학회논문지
    • /
    • 제20권3호
    • /
    • pp.15-20
    • /
    • 2006
  • 본 연구는 상대식 지하철 역사에서 화재발생시 작동되는 두 가지 환기팬 풍량에 의한 열 및 연기 분포 특성 예측을 위하여 수치해석적 연구를 수행하였다. 터널연결부에서 발생되는 자연풍, 배기구 유속 및 온도 등 PART I에서 얻은 계측값을 경계조건으로 입력하였다. 배연용량에 따른 승강장 내의 열, 연기, 가시거리 그리고 유독가스 분포를 파악하기 위하여 2가지 경우를 고려하였다. Case I에서는 해당역사 현장에서 계측한 값을 Case II에서는 국가화재 안전기준(National Fire Safety Codes, NFSC 501)에서 제시한 배연량을 사용하였다. 수치해석 결과에서 보여주듯이 배기구의 유속 크기는 화재에 의한 열 및 연기유동에 크게 영향을 미치는 것을 알 수 있으며, 배연 풍량이 클수록 높은 제연효과를 나타내는 것을 확인 할 수 있었다.

지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구 (A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform)

  • 유지오;이후영
    • 한국터널지하공간학회 논문집
    • /
    • 제24권4호
    • /
    • pp.327-339
    • /
    • 2022
  • 본 연구에서는 지하철 승강장에서 열차화재가 발생하는 경우, 승강장 제연풍량 및 제연모드(급기 또는 배기)에 따른 정량적 위험도 평가를 통해 안전확보에 효과적인 제연풍량 및 모드를 제시함을 목적으로 한다. 이를 위해 중앙계단을 갖는 상대식 승강장을 모델로 하여 화재발생 시나리오를 작성하였으며, 시나리오별 화재해석을 수행하여 연기전파특성과 ASET을 비교·분석하고 대피해석을 수행하여 사망자수를 예측하였다. 또한, 시나리오별로 화재사고 발생률(F)/사망자수(N)선도(F/N선도)를 작성하여 제연풍량 및 제연모드에 따른 위험도를 비교·평가하였다. 소방시설 등의 성능위주 설계 방법 및 기준에서 정하는 유해요소(일산화탄소, 온도, 가시거리)에 대한 ASET 분석에서는 가시거리의 영향이 가장 크게 나타나고 있으며, 화재열차의 승강장 진입지연을 고려하지 않은 경우에 풍량을 4 × 833 m3/min할 때 ASET은 약 800초 정도로 분석되었다. 예상사망자수는 화재차량위치에 따라 큰 차이가 있으며, 계단부에 인접한 차량에서 화재가 발생하는 경우에 선두부 차량대비 3배 까지 증가하는 것으로 나타나고 있다. 또한 제연풍량이 증가하면 사망자수가 감소하며 배기 보다는 급기방식이 감소율이 증가한다. 급기풍량이 4 × 833 m3/min일 때 예상 사망자수는 제연을 수행하지 않는 경우 대비 13%수준으로 감소하는 것으로 나타났다. 위험도 평가결과, 제연을 수행하는 경우에는 현행 사회적 위험도 평가기준을 만족하는 것으로 나타나고 있으며, 예상사망자수는 제연을 수행하지 않는 경우, 10,000년에 29.9명에서 제연을 수행하는 경우에는 풍량이 4 × 833 m3/min일 때 4.36명으로 감소하는 것으로 분석되었다.