• Title/Summary/Keyword: 산소량

Search Result 1,755, Processing Time 0.032 seconds

An Experimental Study on the Determination of the Flow Rate for a Feasible $N_2$ Generator to Extinguish the Fire (소화성능이 있는 질소발생기의 방사량 결정에 관한 실험적 연구)

  • Jang, Young-Keun;Kim, Duk-Joo;Suh, Byung-Taek
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.54-60
    • /
    • 2010
  • An experimental study has been carried out to determine the flow rate for a feasible N2 generator to extinguish the fire, and this study analogized the correlations to determine the flow rate for $N_2$ generator considered an Oxygen concentration, protected enclosure, discharging pressure and discharging time. We manufactured simple protected enclosure for analyzing fire-extinguishing performance of the $N_2$ generator. As a $N_2$ gas is exhausted on protected enclosure, a various of Oxygen concentration is measured to analyze fire-extinguishing performance experimentally. The correlations determined as an uncertainty analysis for the Oxygen concentration deviations of the theoretical and experimental value. The analogized correlations is Q = (21 $\times$ V)/($O_2+{\zeta}{\cdot}P$)-V. In case of $300m^3$ protected enclosure, 0.8 MPa discharging pressure and $40m^3$/min $N_2$ flow rate, the Oxygen concentration is decreased below 15% within 3 minutes.

Effects of trunk stabilization exercise on pulmonary function, maximal oxygen uptake, and heart rate of short-term non-smokers (몸통 안정화 운동이 단기 금연자의 허파기능, 최대 산소 섭취량, 심장박동수에 미치는 영향)

  • Yoo, Kyung-Tae;Jeong, Beom-Cheol;Park, Soon-Jee
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.7
    • /
    • pp.164-171
    • /
    • 2021
  • This study analyzed the post-exercise cardiopulmonary function, maximal oxygen uptake, heart rate and recovery time through smoker's short - term smoking cessation and trunk stabilization exercise for 72 hours. We analyzed the effect of trunk stabilization exercise on the cardiopulmonary function of smokers and non-smokers. As a result, it was found that both smokers and non-smokers groups showed significant changes in pulmonary function (FVC, SVV, MVV), maximal oxygen uptake, recovery time Difference. This suggests that the trunk stabilization exercise may have a positive effect on the cardiopulmonary function of short-term non-smokers as well as non-smokers for a short period of time, and a more stable and effective method for preventing and improving the reduction of cardiorespiratory function

The Effect of Adsorbed Oxygen Species on the Partial Oxidation of Ethylene over Ag/α-Al2O3 (Ag/α-Al2O3 촉매상에서의 에틸렌 부분산화반응에 미치는 흡착산소종의 영향)

  • Baik, Choong-Hoon;Lee, Sang-Gi;Yeo, Jong-Kee;Lee, Ho-In
    • Applied Chemistry for Engineering
    • /
    • v.5 no.4
    • /
    • pp.609-615
    • /
    • 1994
  • Partial oxidation of ethylene over 10wt% $Ag/{\alpha}-Al_2O_3$ catalyst was studied with a pulse reactor which was connected directly to a G. C. When ethylene was injected after oxygen injection at the temperature where molecular adsorption of oxygen is difficult ethylene oxide was evolved. From the results, it is suggested that adsorbed atomic oxygen is related with the evolution of ethylene oxide. The selectivity to ethylene oxide decreased with the decrease of the amounts of adsorbed oxygen and bulk oxygen. Ethylene oxide was either decomposed to ethylene and adsorbed oxygen or isomerized to acetaldehyde. However, the isomerization of ethylene oxide to acetaldehyde was strongly suppressed by the preadsorbed oxygen.

  • PDF

Dynamic Changes of Dissolved Oxygen during Summer Monsoon (하절기 장마동안 용존산소의 역동적 변화)

  • An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.3 s.91
    • /
    • pp.213-221
    • /
    • 2000
  • Seasonal oxygen content and deficit rates were evaluated from 17 sites of Taechung Reservoir during 1993${\sim}$1994. In 1993, river inflows peaked during the monsoon in July${\sim}$August and disrupted thermal stratification and anoxic layers in the headwaters, thereby confining the anoxia to the mid-lake and downlake reach. The volume of anoxic water with < 4 mg/l DO comprised only < 10% of the total lake volume in this period. In contrast, during monsoon 1994, 85% of total lake volume was subject to hypoxic conditions with oxygen concentrations < 30% saturation, resulting in massive fishkills (Hypomesus olidus). Relative areal oxygen deficit (RAOD) was -0.024mg O$_{2}$cm$^{-2}$d$^{-1}$ during monsoon 1993, whereas it rapidly decreased at the rate of 0.080mg O$_{2}$cm$^{-2}$d$^{-1}$ during monsoon 1994. Anoxic factor (AF) showed a same interannual pattern as the RAOD and was greater >50 d in 1994 (76.5 d) than 1993 (21.3 d). Thus, the reservoir showed a river-characteristics (6${\sim}$11 mg/l DO) in 1993 while lacustrine conditions (<4mg/l DO) dominated in 1994. Regression analysis showed that the variation of summer DO was mostly determined (R$^{2}$=0.99, p<0.0001) by inflow. These findings suggest that the primary factor regulating the oxygen content in this system during summer is an intensity of the monsoon rain.

  • PDF

Effect of Oxygen Supply on the Production of Interferon ${\alpha}$-1 by Recombinant Escherichia coli in Fed-batch Fermentation (유가식 배양에서 재조합 대장균으로부터 Interferon ${\alpha}$-1 생산에 산소 공급이 미치는 영향)

  • Yi, Jong-Ghil;Moon, Seok-Young;Kim, Young-Jun;Shin, Chul-Soo;Koo, Yoon-Mo
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.3
    • /
    • pp.226-230
    • /
    • 2007
  • In order to achieve high-level expression of interferon-${\alpha}1$ (IFN-${\alpha}1$) during fed-batch fermentation of recombinant E. coli, effects of oxygen supply and induction temperature on the expression of recombinant proteins were evaluated. Supplementation of oxygen and its transfer into cells is one of the most important parameters involved in the design and operation of mixing-sparging equipment for bioreactors. Generally, higher oxygen supply stimulates cell growth of aerobic microorganism and consequently the amount of products is increased. In this study, the optimum aeration strategy for the higher production of IFN-${\alpha}1$ during fed-batch fermentation of recombinant E. coli was surveyed. The growth of the cells was also monitored with four different concentrations of dissolved oxygen (DO; limiting, 20%, 35%, 50%) conditions. The DO was controlled by varying aeration rates of air and pure oxygen. Oxygen uptake rate (OUR) and specific oxygen uptake rate (SOUR) were evaluated and compared for the enhanced growth and induction of the cells and IFN-${\alpha}1$, respectively. We confirmed that increased DO by additional oxygen supply, up to 35%, can improve the production of IFN-${\alpha}1$ during the fermentation.

Cesium Ions Adsorption of Activated Carbon Treated by Oxygen Plasma (산소 플라즈마 처리된 활성탄소의 세슘 이온 흡착)

  • Ha, Seongmin;Kwak, Cheol Hwan;Lim, Chaehun;Kim, Seokjin;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • The effect of introducing oxygen functional groups by oxygen plasma treatment of activated carbon on adsorption properties of cesium ions was investigated. During the oxygen plasma treatment, the frequency, power, and oxygen gas flow rates were fixed at 100 kHz, 80 W, and 60 sccm, respectively, while the reaction time was varied. Under the experimental conditions, the amount of cesium ion adsorption increased as the content of oxygen groups on C-O-C and O=C-O bonds increased when the reaction time with oxygen gas was 10 minutes. However, when the reaction time increased to 15 minutes, the oxygen functional group content decreased resulting in the decrease of the adsorbed cesium ion amount. On the other hand, unlike the oxygen content of the surface-treated activated carbon, the specific surface area and pore properties were hardly affected by the oxygen plasma reaction time. As a result, the oxygen plasma-treated activated carbon improved the cesium ion removal rate by up to 97.3% compared to that of the untreated activated carbon. This is considered to be due to the content of oxygen groups on C-O-C and O=C-O bonds introduced on the surface of the activated carbon through oxygen plasma treatment.

Water Quality of the Yellow Sea in Summer (하계 황해의 수질 환경 특성)

  • YOU Sun-Jae;KIM Jong-Gu;KIM Gwang-Su
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.6
    • /
    • pp.825-835
    • /
    • 1994
  • The distributions of temperature, salinity, dissolved oxygen, chemical oxygen demand, dissolved inorganic nitrogen and phosphate in the Yellow Sea are described from data collected in June and July, 1994. Based on the observations of water temperature and salinity, the fresh waters originated from the Changjiang River were found to affect the waters adjacent to Cheju Island. In the light of the distributions of dissolved oxygen and chemical oxygen demand, the western part of the Yellow Sea was worse in water quality than the eastern part. Based on data of nutrients, eutrophication indices of the western part were higher than those of the eastern part in summer. It is concluded that the western part of the Yellow Sea appeared to receive high pollution loads from rivers and was evaluated to have high potentiality of red tide occurrence.

  • PDF

Reduction of the Flow Accelerated Corrosion within Low Pressure Evaporator Connection Pipe by Interception of Hydrazine for Water Treatment (탈산소제 차단 수처리에 의한 배열회수보일러 저압증기발생기 연결배관내의 유동가속부식 저감)

  • Son, Byung-Gwan;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.9 no.4
    • /
    • pp.26-30
    • /
    • 2013
  • Based on case that HRSG low pressure steam generator tube was damaged by FAC in 500 MW A CCPP. This case analyzed the effect of application about the block of hydrazine water treatment which is applied for increasing dissolved oxygen. And also try to deduce the major factor of FAC Which is caused by lacking of dissolved oxygen of boiler feed system. After 1 year of water treatment, the figure of dissolved oxygen in the boiler feed water has increased from 0.15 ppb to 3~5 ppb and the figure of oxidation reduction potential has increased from -245 mV to 170 mV. And Iron content, the corrosion products by FAC has decreased from 18.5 ppb to 5~7 ppb. According to the result of experiment, we could able to confirm that the interception of hydrazine of water treatment is effective to reduce FAC.

  • PDF

Effect of the Steam Flow Rate on Syngas Productivity in IGCC Gasifier for a Power Generation (IGCC 발전용 가스화기에서 증기 주입량이 합성가스 생산량에 미치는 영향)

  • Keum, Kyung-Nam;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.15 no.3
    • /
    • pp.29-34
    • /
    • 2019
  • In the study, the effect of steam injection on syngas productivity was investigated under the constant operating conditions of gasifier oxygen load while the coal feed was fixed and the steam injection flow rate is changed in Taean IGCC plant. The maximum syngas average productivity was found to be at 80 % and 90 % of gasifier oxygen loads with the steam injection flow rate of 0.14 kg/s and 0.15 kg/s per coal burner. Through this study, the syngas productivity was changed by adjusting the steam injection amount and as the steam injection flow rate increased, the syngas productivity increased and then decreased again. The syngas productivity can be increased only by steam injection without supplying additional coal and it is considered that the syngas productivity has different characteristics depending on coal type. Thus it is recommended to operate the gasifier using Carbo-One coal with the steam injection flow rate of about 0.14 kg/s per coal burner when the gasifier oxygen load is 80 % ~ 90 %.