• Title/Summary/Keyword: 비틀림 각

Search Result 189, Processing Time 0.021 seconds

Vessel Tracking Algorithm using Multiple Local Smooth Paths (지역적 다수의 경로를 이용한 혈관 추적 알고리즘)

  • Jeon, Byunghwan;Jang, Yeonggul;Han, Dongjin;Shim, Hackjoon;Park, Hyungbok;Chang, Hyuk-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.137-145
    • /
    • 2016
  • A novel tracking method is proposed to find coronary artery using high-order curve model in coronary CTA(Computed Tomography Angiography). The proposed method quickly generates numerous artificial trajectories represented by high-order curves, and each trajectory has its own cost. The only high-ranked trajectories, located in the target structure, are selected depending on their costs, and then an optimal curve as the centerline will be found. After tracking, each optimal curve segment is connected, where optimal curve segments share the same point, to a single curve and it is a piecewise smooth curve. We demonstrated the high-order curve is a proper model for classification of coronary artery. The experimental results on public data set sho that the proposed method is comparable at both accuracy and running time to the state-of-the-art methods.

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

An Experimental Study on the Augmentation of Heat Transfer by Impinging Air Jets with Swirl (충돌선회분류(衝突旋回噴流) 열전달증진(熱傳達增進)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Ohu, Su-Cheol;Park, Sung-Soo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 1993
  • This Paper deals with the experimental study of the axisymmetric air jet impinging vertically on the flat heating surface with and without swirl. The purpose of this study is to investigate the characteristics of flow, augmentation of heat transfer rate, turbulent intensity, and the comparison of heat transfer rate, the optimal swirling condition about the swirl and nonswirl axisymmetric air jet. In order to augment the heat transfer on the flat heating surface without introducing any additional power, the technique used in the present work was placement of twisted tape inserted pipe in front of the nozzle exit in order to make a swirl. The effect of swirl degree is investigated in case of S=0., 0.056, 0.111, 0.222 and the velocity of the jet was 14, 20, 26, 32, 38, 44m/s. The distance between the nozle exit and the stagnation point on the impinging plate was the H/D=$1{\sim}14$. In order to analyze of the flow structure which increase heat transfer, the velocity and the turbulent intensity of the axisymmetric jet was measured by a hot wire anemometer according to the swirl number and H/D.

  • PDF

Evaluation of Pull-out Performance of Torsion Control Expansion Anchor According to Drill Bit Diameter (드릴비트 직경에 따른 비틀림 제어 확장 앵커의 인발성능 평가)

  • Kyoung-Hun Chae;Tae-Wo Park;Moo-Won Hur;Yeong-Seung An;Ju-Yeon Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.64-70
    • /
    • 2023
  • In this study, reliability tests of torsion control expansion anchors according to drill bit diameters were performed. The standard deviation and coefficient of variation of the anchor were reviewed through the tests for each variable, and the results were compared and evaluated with the standard test results. As a result of the reliability test of the M12 and M16 anchors with 1.04 times the drill bit diameter, they were within 20% of the ultimate tensile load permissible standard coefficient of variation. It was found that the pulling-out performance of the anchor installed in the large hole was sufficiently secured. However, it was found to be about 253% and 210% of the design strength, indicating that the pulling performance of the anchor installed in 1.04 times the drill bit diameter was sufficiently secured. As a result of the reliability test of the M12 and M16 anchors with 1.02 times the drill bit diameter, the value of the coefficient of variation of the ultimate tensile load limit was within 20%, which satisfies the test standard. It was shown to be about 136% and 168% of the design strength, indicating that the pulling-out performance of the anchor installed in 1.02 times the drill bit diameter is sufficiently secured.

Biomechanics analysis by golf drive swing pattern (골프 드라이브 스윙시 구질 변화에 따른 운동학적 분석)

  • Choi, Sung-Jin;Park, Jong-Jin;Yang, Dong-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.259-278
    • /
    • 2002
  • This study divided straight success, pade success and failure with 7male golfers who have experiences more than 3 years, analyzed kinematic factors of golf swing to suggest scientifically. The conclusions were follows. 1) The wrist angle has significant difference in straight success, pade success and failure when swing of every pattern. There is no significant difference in pade success and failure. 2) The body twist angle has no significant difference in straight success, pade success and failure when swing of every pattern. There is no significant difference in pade success and failure. 3) The shoulder joint rotation angle has no significant difference in success, pade success and failure when swing of every pattern. There is no significant difference in pade success and failure. 4) The left hip joint vertical angle has no significant difference in straight success, pade success and failure when swing of every pattern. There is no significant difference in pade success and failure. 5) The hip joint rotation angle has no significant difference in straight success, pade success and failure when swing of every pattern. There is no significant difference in pade success and failure. 6) The trunk angle has no significant difference in straight success, pade success and failure when swing of every pattern. There is no significant difference in pade success and failure. 7 )The left knee joint angle has no significant difference in straight success, pade success and failure when swing of every pattern. There is no significant difference in pade success and failure. This study divided golf swing motion of pattern change in straight success, pade success and failure and analyzed the kinematic factors by 3-dimension cinematography to improve performance. In the future, many researchers have to study kinematic analysis to improve performance in every events.

Static Strength of Composite Single-lap Joints Using I-fiber Stitching Process with different Stitching Pattern and Angle (I-fiber Stitching 공법을 적용한 복합재료 Single-lap Joint의 Stitching 패턴과 각도에 따른 정적 강도 연구)

  • Song, Sang-Hoon;Back, Joong-Tak;An, Woo-Jin;Choi, Jin-Ho
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.296-301
    • /
    • 2020
  • Laminated composite materials have excellent in-plane properties, but are vulnerable in thickness directions, making it easy to delamination when bending and torsion loads are applied. Thickness directional reinforcement methods of composite materials that delay delamination include Z-pinning, Stitching, Tufting, etc., and typically Z-pinning and Stitching method are commonly used. The Z-pinning is reinforcement method by inserting metal or carbon pin in the thickness direction of prepreg, and the conventional stitching process is a method of reinforcing the mechanical properties in the thickness direction by intersecting the upper and lower fibers on the preform. In this paper, I-fiber stitching method, which complement and improve weakness of Z-pinning and Stitching method, was proposed, and the static strength of composite single-lap joints using I-fiber stitching process were evaluated. The single-lap joints were fabricated by a co-curing method using an autoclave vacuum bag process. The thickness of the composite adherend was fixed, and 5 types of specimens were manufactured with varying the stitching pattern (5×5, 7×7) and angle (0°, 45°). From the test, the failure load of the specimen reinforced by the I-fiber stitching process was increased by up to 143% compared to that of specimen without reinforcement.

An Estimate of Ballast Track Condition on Dynamic Behavior of Railway Bridge (철도교량의 동적거동 특성을 고려한 자갈도상궤도의 상태추정에 관한 연구)

  • Kweon, Oh-Soon;Choi, Jung-Youl;Kang, Myoung-Seok;Lee, Hee-Up;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.480-493
    • /
    • 2007
  • Many railway-advanced countries are using the various types of track to reduce the track maintenance and repair cost according to the improvement of velocity. It spends on much maintenance and repair cost for ballast track due to abrasion of ballast, track irregularity and unisotropical ballast-support stiffness. The ballast track on railway bridge is accelerating the deterioration of ballast according to interaction of railway bridge and track. As continuing the deterioration, it is caused dynamic loads. Due to these effects, it increases negative loads of track and bridge. However, when designing the railway bridge, the effect of ballast track was applicate only dead load, so elastic behavior effect of ballast track is not influenced. Therefore, this paper presumes the stiffness of ballast track on railway bridge considering dynamic behavior of railway bridge, it was evaluated that effect on dynamic behaviors of railway bridge according to ballast track stiffness.

  • PDF

Analysis of the Effectiveness of a University Affiliated Science-Gifted Educational Program: The Case of C Gifted Education Center (C 영재교육원을 통해 살펴본 대학부설 과학영재교육원 프로그램 효과성 분석)

  • Han, Ki-Soon;Yang, Tae-Youn
    • Journal of The Korean Association For Science Education
    • /
    • v.29 no.2
    • /
    • pp.137-155
    • /
    • 2009
  • The purpose of the present study was to analyse the effectiveness of a gifted education program. To analyse the effectiveness of an education program for the gifted affiliated with a university, the study carried out a quasi-experimental design to compare the 153 gifted students who enrolled in an education center for the gifted and the 131 potentially gifted students who were nominated by teachers for their high achievements and interests in science but without any education services for the gifted. These two groups of students were compared in the aspects of problem finding ability in science, motivation, self regulation, science-related attitudes, and science anxiety through the pre- and post-treatment settings. The results indicated that the gifted group showed a significant improvement in originality and elaboration of problem-finding ability, but the potentially gifted group showed significant decrease in most variables of problem finding. Related to motivation and self-regulated learning, gifted students showed an increase in cognitive strategy use and decrease in intrinsic value, but the potentially gifted students showed significant decreases in most variables related to motivation and self-regulation, except intrinsic value. Related to the scientific attitudes and science anxiety, there were no significant changes between pre- and post-tests in the gifted group, but significant decreases in most variables were found in the potentially gifted group. The results of paired t-test and Ancova indicate that significant differences between the gifted and the potentially gifted groups are mainly due to the significantly lowered performance in post tests in the potentially gifted group, rather than a significant increase in gifted group.

Primer Evaluation for the Detection of Toxigenic Microcystis by PCR (독소 생성 Microcystis 검출을 위한 PCR primer의 평가)

  • 이현경;김준호;유순애;안태석;김치경;이동훈
    • Korean Journal of Microbiology
    • /
    • v.39 no.3
    • /
    • pp.166-174
    • /
    • 2003
  • Microcystin produced by cyanobacteria in surface waters, such as eutrophic lake and river, is a kind of serious environmental problems due to its toxicity to human and wild animals. Microcystin is synthesized nonribosomally by the large modular multi-functional enzyme complex known as microcystin synthetase encoded by the mcy gene cluster. Amplification of mcy genes by PCR from cultures and environmental samples is a simple and efficient method to detect the toxigenic Microcystis. In order to evaluate primers designed to detect toxic microcystin-producing strains, 17 cyanobacterial strains and 20 environmental samples were examined by PCR with 7 pairs of primers. Some microcystin-producing cyanobacteria were not detected with FAA-RAA, TOX4F-TOX4R and FP-RP primers. The fragment of unexpected size was amplified with NSZW2-NSZW1 primers in Microcystis strains isolated from the lakes in Korea. TOX1P-TOX1F primers failed in amplification of toxin-producing strains. Only MSF-MSR and TOX2P- TOX2F primers amplified the fragments of mcy genes from 11 strains of microcystin-producing Microcystis. The water samples taken from 20 lakes in Korea were analyzed by PCR using each of the primers. In all the water samples, cyanobacteria capable of producing microcystin were detected by the PCR with TOX2P-TOX2F primers. These results indicate that TOX2P-TOX2F primers are better than the other primers for detection of microcystin-producing Microcystis strains in Korea. The nucleotide sequences of mcy gene in Microcystis aeruginosa NIER10010 suggest genetic diversity of Korean isolates.