• 제목/요약/키워드: 비정렬

Search Result 641, Processing Time 0.021 seconds

CoFe2O4 Films Grown on (100) MgO Substrates by a rf Magnetron Sputtering Method ((100) MgO 기판에 성장한 CoFe2O4 박막의 물리적 및 자기적 특성에 관한 연구)

  • Lee, Jae-Gwang;Chae, Kwang-Pyo;Lee, Young-Bae
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.2
    • /
    • pp.140-143
    • /
    • 2006
  • Single crystalline $CoFe_2O_4$ thin films on (100) MgO substrates were fabricated using a rf magnetron sputtering method. The deposited films were investigated for their crystallization by X-ray diffraction, Rutherford back-scattering spectroscopy and field emission scanning electron microscopy. When a cobalt ferrite film was deposited at the substrate temperature of $600^{\circ}C$, squared grains of about 200 nm were uniformly distributed in the film. However, the grains became irregular and their sizes also varied from 30 to 150 nm when the substrate temperature was $700^{\circ}C$. Hysteresis loops of a film deposited at $600^{\circ}C$ showed that the magnetically easy axis of the film was perpendicular to the substrate surface. Except for the squareness ratio, magnetic properties of the cobalt ferrite films grown by the present rf sputtering method were as good as those of the films prepared by a laser ablation method: The in-plane and perpendicular coercivities were 283 and 6800 Oe, respectively. As the thickness of the deposited film increased twice, the saturation magnetization became double but the coercivity remained unchanged. However, deposition of the Co ferrite films with a higher rf powder decreased the squareness ratio and the perpendicular coercivity of the films.

Advanced LWIR Thermal Imaging System with a Large Zoom Optics (줌 광학계를 이용한 원적외선 열상장비의 설계 및 제작)

  • Hong, Seok-Min;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.354-360
    • /
    • 2005
  • A high performance LWIR(long wavelength infra red) zoom thermal imaging sensor using $480{\times}6$ HgCdTe(MCT) linear detector has been developed by ADD Korea. The optical system consists of zoom telescope having large objective about 190 mm diameter and optically well corrected scanning system. The zoom ratio of the telescope is 3: 1 and its magnification change is performed by moving two lens groups. And also these moving groups are used for athermalization of the system. It is certain that the zoom sensor can be used in wide operating temperature range without any degradation of the system performance. Especially, the sensor image can be displayed with the HDTV(high definition television) format of which aspect ratio is 16:9. In case of HDTV format, the scanning system is able to display 620,000 pixels. This function can make wider horizontal field of view without any loss of performance than the normal TV format image. The MRTD(minimum resolvable temperature difference) of the LWIR thermal imaging sensor shows good results below 0.04 K at spatial frequency 2 cycles/mrad and 0.23 K at spatial frequency 8 cycles/mrad at the narrow field of view.

Speckle Noise Removal by Rank-ordered Differences Diffusion Filter (순위 차 확산 필터를 이용한 스페클 잡음 제거)

  • Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.1
    • /
    • pp.21-30
    • /
    • 2009
  • The purposes of this paper are to present a selection method of neighboring pixels whose local statistics are similar to the center pixel and combine the selection result with mean curvature diffusion filter to reduce noises in remote sensed imagery. The order of selection of neighboring pixels is critical, especially for finding a pixel belonging to the homogeneous region, since the statistics of the homogeneous region vary according to the selection order. An effective strategy for selecting neighboring pixels, which uses rank-order differences vector obtained by computing the intensity differences between the center pixel and neighboring pixels and arranging them in ascending order, is proposed in this paper. By using region growing method, we divide the elements of the rank-ordered differences vector into two groups, homogeneous rank-ordered differences vector and outlier rank-ordered differences vector. The mean curvature diffusion filter is combined with a line process, which chooses selectively diffusion coefficient of the neighboring pixels belonging into homogeneous rank-ordered differences vector. Experimental results using an aerial image and a TerraSAR-X satellite image showed that the proposed method reduced more efficiently noises than some conventional adaptive filters using all neighboring pixels in updating the center pixel.

Study on the Hydrophobicity and Mechanical Properties of Silica-Based Aerogel by Introducing Organic Benzene (벤젠 유기물 도입에 따른 실리카 기반 에어로겔의 소수성 및 기계적 특성 연구)

  • Qi, Wang;Lee, Jihun;Dhavale, Rushikesh P.;Choi, Haryeong;Kim, Taehee;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.135-141
    • /
    • 2020
  • The silica aerogels with benzene-bridged were designed to have uniform network structure, ordered pore structure, improved mechanical properties and excellent textural properties. Adding organic to enhance the mechanical properties of silica aerogels is a common method, but textural properties of aerogels with organic are reduced due to the organic-inorganic phase separation. In this paper, we use a simple and low-cost method to increase mechanical properties while maintaining textural properties of SiO2 aerogels. Two types of benzene-bridged precursors were prepared to study the effect of the number of hydroxyl band on the textural and mechanical properties. The porous silica aerogel was prepared by a simple, cost effective and pollution-free sol-gel method. This method does not require additional silylating reagents. The benzene-bridged silica aerogel samples prepared had excellent textural properties, high specific surface area (1,326 ㎡/g), porous structure and hydrophobicity (>140°). The mechanical strength of 2T4 is more than 5 times that of pure silica aerogel.

Characteristic Analysis of Efficiency and Impedance With WPT Transmitter and Receiver Coil Distance (무선전력전송 송수신코일 거리에 따른 효율 및 임피던스 특성 해석)

  • Park, Dae Kil;Kim, Young Hyun;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.3
    • /
    • pp.160-165
    • /
    • 2022
  • In this paper, we have proposed a magnetic resonant 6.78MHz WPT(wireless power transfer) technique which can be applied to a fixed transmitter and a receiver of varying relative distance and coil alignment, Power transmission characteristics are studied with the relative distance and misalignment ration of coil area between the transmitting and receiving coils. The coils are designed with the size of 60×80mm2 by direct feeding method, and the characteristics are derived with the maximum relative distance of 50mm and horizontal area misalignment state of 0-40mm misalignment of coil center axis in the XY plane. The power transmission characteristics are compared between the 3D EM simulation and the measured data, and the power transmission shows larger than -3dB performance with the vertical distance of up to 30mm and 50% area misalignmment ratio. This work showsthe transmission characteristics according to relative distance and misalignment state between the cols and that direct feeding has advantage for the short relative distance and small misalignment ratio.

Improvement of Silkworm Egg Microinjection Using 3D Printing Technology (3D 프린팅 기술을 이용한 누에 알 미세주입 기술 개선)

  • Jeong, Chan Young;Lee, Chang Hoon;Seok, Young-Seek;Yong, Sang Yeop;Kim, Seong-Wan;Kim, Kee Young;Park, Jong Woo
    • Korean journal of applied entomology
    • /
    • v.61 no.1
    • /
    • pp.249-254
    • /
    • 2022
  • Silkworms, which have for long been used as an insect resource for industrialization, have recently attracted attention as potential bio-factories for the production of novel biomaterials. In this regard, material production is typically achieved based on transformation technology, mediated via microinjection, in which a target gene is inserted into eggs containing an embryo. However, an essential step in the microinjection procedure is egg fixation, which can be a time-consuming and laborious task. Therefore, in this study, using the 3DCADian program, we adopted a 3D printing approach to model egg liners and glue drawers, which can contribute to facilitating egg alignment and fixation, thereby enhancing transformation efficiency by reducing time consumption and fatigue. After rendering using Fusion 360, the two supplementary tools were produced by printing with nylon resin (PA12) and Sinterit Lisa Pro. Subsequent analysis of the time required to fix eggs on glass slides using the two manufactured tools, revealed that the processing time was reduced by approximately 18.6% when the two tools were used compared with when these tools were not used. These innovations not only reduced fatigue but also contributed to more effective use of the microscope and manipulator for microinjection. Consequently, we believe that with additional research and refinement, the egg liner and glue drawer developed in this study could be used to enhance silkworm transformation efficiency and study similar transformation systems in other industrial insects.

A Modified grid-based KIneMatic wave STOrm Runoff Model (ModKIMSTORM) (I) - Theory and Model - (격자기반 운동파 강우유출모형 KIMSTORM의 개선(I) - 이론 및 모형 -)

  • Jung, In Kyun;Lee, Mi Seon;Park, Jong Yoon;Kim, Seong Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.697-707
    • /
    • 2008
  • The grid-based KIneMatic wave STOrm Runoff Model (KIMSTORM) by Kim (1998) predicts the temporal variation and spatial distribution of overland flow, subsurface flow and stream flow in a watershed. The model programmed with C++ language on Unix operating system adopts single flowpath algorithm for water balance simulation of flow at each grid element. In this study, we attempted to improve the model by converting the code into FORTRAN 90 on MS Windows operating system and named as ModKIMSTORM. The improved functions are the addition of GAML (Green-Ampt & Mein-Larson) infiltration model, control of paddy runoff rate by flow depth and Manning's roughness coefficient, addition of baseflow layer, treatment of both spatial and point rainfall data, development of the pre- and post-processor, and development of automatic model evaluation function using five evaluation criteria (Pearson's coefficient of determination, Nash and Sutcliffe model efficiency, the deviation of runoff volume, relative error of the peak runoff rate, and absolute error of the time to peak runoff). The modified model adopts Shell Sort algorithm to enhance the computational performance. Input data formats are accepted as raster and MS Excel, and model outputs viz. soil moisture, discharge, flow depth and velocity are generated as BSQ, ASCII grid, binary grid and raster formats.

3DentAI: U-Nets for 3D Oral Structure Reconstruction from Panoramic X-rays (3DentAI: 파노라마 X-ray로부터 3차원 구강구조 복원을 위한 U-Nets)

  • Anusree P.Sunilkumar;Seong Yong Moon;Wonsang You
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.7
    • /
    • pp.326-334
    • /
    • 2024
  • Extra-oral imaging techniques such as Panoramic X-rays (PXs) and Cone Beam Computed Tomography (CBCT) are the most preferred imaging modalities in dental clinics owing to its patient convenience during imaging as well as their ability to visualize entire teeth information. PXs are preferred for routine clinical treatments and CBCTs for complex surgeries and implant treatments. However, PXs are limited by the lack of third dimensional spatial information whereas CBCTs inflict high radiation exposure to patient. When a PX is already available, it is beneficial to reconstruct the 3D oral structure from the PX to avoid further expenses and radiation dose. In this paper, we propose 3DentAI - an U-Net based deep learning framework for 3D reconstruction of oral structure from a PX image. Our framework consists of three module - a reconstruction module based on attention U-Net for estimating depth from a PX image, a realignment module for aligning the predicted flattened volume to the shape of jaw using a predefined focal trough and ray data, and lastly a refinement module based on 3D U-Net for interpolating the missing information to obtain a smooth representation of oral cavity. Synthetic PXs obtained from CBCT by ray tracing and rendering were used to train the networks without the need of paired PX and CBCT datasets. Our method, trained and tested on a diverse datasets of 600 patients, achieved superior performance to GAN-based models even with low computational complexity.

PULSE RATE AND OXYGEN SATURATION IN CHILDREN DURING ROUTINE RESTORATIVE DENTISTRY (소아 치과치료시 심박동과 동맥혈 산소포화도의 변화)

  • Kim, Ha-Na;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Park, Jeong-Yeol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.65-72
    • /
    • 2008
  • Pulse oximeter to monitor oxygen saturation during pediatric dental sedations enables early detection of hypoxemia. The purpose of this study was to monitor the hemoglobin oxygen saturation level and pulse rate of nonmedicated pediatric patients during routine restorative procedures to study the effect of procedure and treated jaw. We obtained data from 53 children treated at the Department of Pediatric Dentistry, Chonbuk national university hospital. Pulse rate and oxygen saturation were measured and recorded using pulse oximetry at each step of treatment. The results are as follows: 1. In non-anesthesia group, steep increase of pulse rate was observed during rubber dam application in the maxilla and during cavity preparation in the mandible. 2. In anesthesia group, pulse rate started to decrease after the rubber dam application in the maxilla, while its decrease observed since cavity preparation step in the mandible. 3. In non-anesthesia group, oxygen saturation level was relatively constant during all steps in the maxilla, but in mandible, it was higher during operation compared to its pre and post operation baseline. 4. In anesthesia group, oxygen saturation level was observed at 99% level through all steps in both jaw groups, and there was no statistical significance between the maxilla and the mandible groups(p>0.05). The purpose of this study was to evaluate the effect of routine dental treatment on the pulse rate and oxygen saturation level in nonmedicated pediatric patients during routine restorative procedures in the maxilla and mandible.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.