Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers (접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향)

  • Choi, Ik-Hwang;Lee, Jae-Ik;Kwon, Goo-Do;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.358-363
    • /
    • 2008
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Thus, in this study, we investigate the effects of such experimental system dependent factors in the measurement of ultrasonic nonlinear parameter by using contact PZT transducer. Experimental results showed that the effect of system dependent nonlinearity is reduced when the contact pressure and transducer input voltage are sufficiently large. These results will be very useful to find out the proper experiment condition to measure rather accurate nonlinear parameter.

Experimental Study on Non-contact Type Inspection System for Wing Rib Thickness Measurement (윙립 두께 측정용 비접촉식 검사 시스템에 관한 실험적 연구)

  • Lee, In-Su;Kim, Hae-Ji;Ahn, Myung-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.104-110
    • /
    • 2014
  • This paper presents a non-contact inspection system for automatically measuring the thickness of an aircraft wing rip product. In order to conduct the inspection of the wing rib thickness automatically, a non-contact laser displacement sensor, end-effector, and a robot were selected for use. The non-contact type inspection system was evaluated by measuring the measurement deviation of the rotation direction of a C-type yoke end-effector and the transfer direction of a V-slim end-effector. In addition, the non-contact inspection system for wing rib thickness measurements was validated through thickness measurements of a web, flange, and stiffener.

Advances in Hardware of Ultrasonic Propagation Imaging System (초음파전파영상화 시스템 하드웨어 발전)

  • Jeong, Hyo-Mi;Lee, Jeong-Ryul;Park, Chan-Ik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.214-219
    • /
    • 2012
  • 초음파전파영상화(UPI) 시스템은 2007년에 첫 논문 발표를 통해 시스템 개발이 보고된 이후 소프트웨어 및 하드웨어적 측면에서 다양한 형태로 발전된 시스템의 개발이 이루어졌다. 본 기고에서는 기본 UPI 시스템, 섬유파트랜스듀서 UPI 시스템, 순수광학시스템으로서 광섬유 센서 UPI 시스템, 완전비접촉 시스템으로서의 공기정압압전센서 UPI 시스템 및 레이저도플러진동계 UPI 시스템, 장거리 UPI 시스템, 옥외 적용성에 필수적인 저온환경 UPI 시스템 등을 소개한다.

A Study on Adaptable Non-contact Shape Inspection System (적응형 비접촉 형상 검사에 관한 연구)

  • Kang, Young-June;Park, Nak-Gyu;Lee, Dong-Hwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.74-80
    • /
    • 2005
  • A new dimension measuring method for the measurement of diameter of an object has been developed using laser triangulation. The 3D data of an object was calculated from the 2 dimensional image information obtained by the laser stripe using the laser triangulation. The system that use existing theory can measure the diameter of hole not only in a normal plane but also ill an incline plane. However, in the existing theory, since the lens with fixed feral length was used, the area of measurement was fixed. The simplest way to solve this problem is to change distance between a CCD camera and object. Other way is to use a zoom lens having variable focal length. In this paper, the zoom lens with variable focal length was used. Therefore, we ran experiment with magnification that is optimized according to size of object using zoom lens with variable focal length.

Spot detection of Optical lens using the image processing (영상 처리에 의한 광학렌즈 이물 검출)

  • Song, Young-Jun;Kim, Dong-Woo;Kim, Nam;Ahn, Jae-Hyeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.73-75
    • /
    • 2009
  • 본 논문은 영상 처리에 의해 광학렌즈의 먼지 및 이물질의 유무를 검출하기 위한 방법을 제안한다. 현재 사용되고 있는 비접촉 검사용 비젼 시스템은 마스크 기법을 활용하여 기준 영상에 비해 어느 정도의 잡음이 있는지를 검사한다. 그러나 조명의 정도, 반사 및 이물질의 유형에 따라 검출하기가 어렵다. 이를 해결하기 위해 파란색 LED 광원을 수평축에 설치하여 양각 부분의 에지들을 더욱 강조하는 시스템을 구현하였다. 이물질 검출은 간단한 소벨 에지 마스크를 사용하고 이물질의 크기에 따라 먼지 및 이물질에 대한 판단을 결정하였다. 크기 및 색상이 틀린 렌즈를 사용하여 실험한 결과 일반 영상에서 검출한 것보다 파란색 LED 광원과 영상처리에 의해 잡음 및 이물질을 강건하게 검출하여 렌즈의 자동 검사용 로봇 비젼 시스템에 적용이 가능하다.

  • PDF

Radiant Energy Filtering to Enhance High Temperature Measurement by a Thermography System (고온 계측 열화상 시스템 구현을 위한 복사에너지 필터링 연구)

  • Yoon, Seok Tae;Cho, Yong Jin;Jung, Ho Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.466-473
    • /
    • 2016
  • In a shipbuilding process, thermal damage to the ship structure at the rear end results from an excessive heat input and conduction during welding process. To prevent such damage, appropriate control of the heat input, based on welding temperature measurement, is required. For temperature measurement, contact and non-contact methods are available; the thermography system is a popular non-contact temperature measurement. When the intensity of radiation from a high-temperature object is excessive, however, detecting the sensors of ordinary thermography systems leads to an inability in measuring the temperature due to saturation. Hence, this study suggests use of a neutral density filter that prevents an excessive amount of radiation from being accumulated in a thermography system, and thus makes it possible to quantitatively measure an object's temperature as high as $3000^{\circ}C$.

Evaluation of illumination effect for on-board spectrometer system (내장형 분광광도시스템 구성에 따른 조명 영향 평가)

  • Lee, Sangsik;Lee, Choongho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.2
    • /
    • pp.18-24
    • /
    • 2010
  • On-board spectrophotometer has been widely used as a non-contact and non-destructive measurement system in many fields. In this study, we evaluated the effect with respect to the light of on-board spectrophotometer based on a comparison with the standard spectrophotometer and color information coordinate system. Red, yellow, green and blue color paper, which were the standard reflective color paper and Munsell color paper, were used for experiments. In order to compare between a standard spectrophotometer system and an on-board spectrophotometer system, each color paper was measured 20 times. We concluded that it is possible to develop a system regardless the effect of light if the light was supplied consistently and a calibration was performed exactly while we applied an on-board spectrophotometer to non-contact and non-destructive measurement system.

  • PDF

High Speed 30 Measurement of BGAS(Ball Grid Arrays) (BGA(Ball Grid Array)의 고속 3차원 측정)

  • 조태훈;장동선
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10b
    • /
    • pp.481-483
    • /
    • 2001
  • 최근 전자제품의 초소형화에 따라, PCB 기판위의 부품의 집적도를 높이기 위해, 기존의 리드대신 부품 밑면에 볼(ball)이 격자형태로 배열되어 있는 BGA(Ball Grid Array) 형태의 팩키지가 많이 사용되고 있다. 하지만, BGA의 구조상 한번 장착되면 외관검사가 불가능하므로, 장착전 BGA의 검사가 필수적이다. BGA의 검사항목중 가장 중요한 항목인 볼 높이검사를 실시간으로 하기 위해서는 고속 비접촉 3차원 측정기술이 요구된다. 본 논문에서는 일반카메라보다 100배이상 높이 프로파일 취득속도가 빠른 3D smart camera와 레이저 슬릿광(slit ray)을 이용하여 고속으로 BGA 볼의 3D 프로파일을 얻은 후, clipping과 morphological filter를 사용하여 인접한 볼표면에서의 난반사로 인한 에러 데이터를 보정하여 정확한 3D 영상을 취득할 수 있는 시스템을 소개한다.

  • PDF

Development of capacitive Micromachined Ultrasonic Transducer (III) - Performance Test (미세가공 정전용량형 초음파 탐촉자 개발(III) - 탐촉자 성능평가)

  • Kim, Ki-Bok;Ahn, Bong-Young;Park, Hae-Won;Kim, Young-Joo;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.581-589
    • /
    • 2004
  • In this study, the capacitive micromachined ultrasonic transducer(cMUT) was developed based on the previous research results. The cross sectional image of the developed cMUT was characterized. To measure the membrane displacement of the cMUT, the Michelson phase modulation fiber interferometer was constructed. The measured membrane displacement was in good agreement with the result of the finite element analysis. To estimate the ultrasonic wave generated by the cMUT, an ultrasonic system including a pulser, receiver and charge amplifier was used. The cMUT developed in this study shows a good performance and hence will be widely used in the non-contact ultrasonic applications.