• Title/Summary/Keyword: 비색 센서

Search Result 9, Processing Time 0.027 seconds

Colorimetric Sensing Behavior of Curcumin Printed on Paper and Cotton Fabric (커큐민으로 프린팅된 종이와 면직물의 유해가스에 대한 색채 감지 거동)

  • Kim, Minhee;Lee, Hoik;Park, Yoon Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.4
    • /
    • pp.260-267
    • /
    • 2021
  • Increasing the needs for eco-friendly natural materials, much attention on natural dyes has been attracted. Curcumin, one of abundant natural dyes available in nature, is an eco-friendly molecule found in turmeric. In this study, the colorimetric sensing behavior characteristics of ammonia and hydrogen chloride gases was analyzed using curcumin ink-printed paper and cotton fabric by inkjet printing method. The fabricated paper and fabric were utilized as a colorimetric sensor that can track food spoilage. The color changes of the samples printed on the paper and cotton upon exposure to the toxic gases, the reversibility of the color changes, and the water resistance were investigated. Both samples showed reversible reactions with NH3 and HCl, and small amount of ammonia produced by food spoilage was successfully sensed with naked eyes, confirming its capability to warn food spoilage in our daily life.

Recent Advances in Electrochromic Sensors (전기화학 기반의 전기 변색 센서 연구 동향)

  • Seo, Minjee
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.4
    • /
    • pp.125-133
    • /
    • 2022
  • Along with the increasing need for point-of-care diagnostics, development of portable, user-friendly, as well as sensitive sensors have gained intensive attention. Among various strategies, electrochromic sensors, which are electrochemically operated colorimetric sensors, have been actively studied. With their ability to report the presence and concentration of analytes by optical signals, electrochromic sensors utilize the advantages of both electrochemical and colorimetric sensors, enabling the simplification of device composition as well as convenient interpretation of results. Up to date, electrochromic sensors have been applied for a wide range of analytes, and further developments such as the introduction of flexible platforms or self-powered systems have been reported, providing a path towards the development of wearable sensor devices. In this review, various types of electrochromic sensors, according to the main strategy in which the electrochemical signals are converted to colorimetric signals, are introduced.

Read-Out Integrated Circuit of Colorimetry-Based Optical Sensor for Eutrophication Analysis (수생태계 부영양화 분석을 위한 비색법 기반의 광학식 센서 신호처리회로(ROIC)구현)

  • Koo, Seong Mo;Jung, Dong Geon;Choi, Young Chan;Kim, Kyung-Kyoo;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.270-274
    • /
    • 2020
  • In this study, a read-out integrated circuit (ROIC) that can be applied to a colorimetry-based optical sensor for analyzing total phosphorus and total nitrogen was developed and characterized. The proposed ROIC minimizes the effect on temperature fluctuation, improves sensitivity, and extends the dynamic range by utilizing a dual optical path and feedback control circuit. Using a dual optical path makes it possible to calibrate the output signal of the optical sensor automatically, along with the temperature fluctuation. The calibrated voltage is fed back into the measurement stage; thus, the output current of the measurement is adaptively controlled. As a result, the sensitivity and dynamic range of the proposed ROIC are improved. Finally, a total-phosphorus analysis was conducted by utilizing the ROIC. The ROIC was found to operate stably over a wide temperature range.

Determination of $K^+-, Ca^{2}+- and Mg^{2+}-$ATPase activities in Fish Muscle Protein by ATPase Biosensor (ATPase 센서를 이용한 어류근육 단백질의 $K^+-, Ca^{2}+- 및 Mg^{2+}-$ ATPase 활성의 측정)

  • 천병수;김희경
    • KSBB Journal
    • /
    • v.11 no.5
    • /
    • pp.518-523
    • /
    • 1996
  • The sensor to determine ATPase activities was consisted of an immobilized enzyme membrane(purine nucloside phosphoryrase and xanthine oxidase) and an oxygen electrode. The proposed sensor was used for the determination of $K^+-, Ca^{2}+- and Mg^{2+}-$ATPase activities in several fish muscle proteins such as Thunnus albacares(Yellowfin tuna), Tetrapturus audax(Striped marlin), Prognichthys agoo(Japanese flyingfish), and Cypvinus carpio(Carp). $K^+-, Ca^{2}-$ATPase activities measured by the proposed sensor system were in good agreement with the results obtained by a conventional colorimetric assay. One cycle of assay could be completed within 3mlnutes.

  • PDF

Development of Electro-Biosensor for the Residual Pesticides using Organic Carbon and Cobalt Phthalocyanine (Cobalt Phthalocyanine 탄소유기 전극을 이용한 농약 잔류량 측정 센서개발)

  • Yu, Young-Hun;Cho, Hyung-Jun;Park, Won-Pyo;Hyun, Hae-Nam
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.1
    • /
    • pp.72-76
    • /
    • 2010
  • We have developed the bio-electrode measuring the variance of the amount of acetylcholine affected by residual pesticide. The working electrode of the biosensor was made by combination of cobalt phthalocyanine and carbon organic compounds. The biosensors were constructed by screen-printing method. The principle of working electrode is similar to thiocholine sensor. We have fabricated the biosensor using standard screen printing method. Generally, the biosensor made by printing method formed thick film biosensor. When the electrodes were made by electrochemical cells, the generation of current by the addition of enzyme substrate was inhibited by standard solutions of organo-phosphate pesticides. The detection limit of sensor is about 0.5 $\mu{g}/L$ for carbofuran. We could improve the responsibility of the sensor by controlling the cobalt phthalocyanine and thiocholine concentration ratio. Also we have tested the EPN and Chlorpyrifos pesticides and found that the biosensor is applicable to fast determination of residual pesticides.

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.

Machine Vision Platform for High-Precision Detection of Disease VOC Biomarkers Using Colorimetric MOF-Based Gas Sensor Array (비색 MOF 가스센서 어레이 기반 고정밀 질환 VOCs 바이오마커 검출을 위한 머신비전 플랫폼)

  • Junyeong Lee;Seungyun Oh;Dongmin Kim;Young Wung Kim;Jungseok Heo;Dae-Sik Lee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.112-116
    • /
    • 2024
  • Gas-sensor technology for volatile organic compounds (VOC) biomarker detection offers significant advantages for noninvasive diagnostics, including rapid response time and low operational costs, exhibiting promising potential for disease diagnosis. Colorimetric gas sensors, which enable intuitive analysis of gas concentrations through changes in color, present additional benefits for the development of personal diagnostic kits. However, the traditional method of visually monitoring these sensors can limit quantitative analysis and consistency in detection threshold evaluation, potentially affecting diagnostic accuracy. To address this, we developed a machine vision platform based on metal-organic framework (MOF) for colorimetric gas sensor arrays, designed to accurately detect disease-related VOC biomarkers. This platform integrates a CMOS camera module, gas chamber, and colorimetric MOF sensor jig to quantitatively assess color changes. A specialized machine vision algorithm accurately identifies the color-change Region of Interest (ROI) from the captured images and monitors the color trends. Performance evaluation was conducted through experiments using a platform with four types of low-concentration standard gases. A limit-of-detection (LoD) at 100 ppb level was observed. This approach significantly enhances the potential for non-invasive and accurate disease diagnosis by detecting low-concentration VOC biomarkers and offers a novel diagnostic tool.

Paper-Based Neuraminidase Assay Sensor for Detection of Influenza Viruses (인플루엔자 바이러스 검출을 위한 종이 기반 neuraminidase 효소 활성 평가 센서 개발)

  • Hwang, Cheol-hwan;Jeong, Seong-Geun;Park, Han-Kyu;Lee, Chang-Soo;Kim, Yun-Gon
    • Korean Chemical Engineering Research
    • /
    • v.54 no.3
    • /
    • pp.380-386
    • /
    • 2016
  • In this study, we described a paper-based neuraminidase assay sensor (PNAS) which can be applied to detect the infection by influenza viruses. The PNAS was designed and manufactured to quantitatively identify the levels of neuraminidase in the sample, which is based on colorimetric analysis using the X-Neu5Ac substrate. The limit of detection of the PNAS was determined as 0.004 U/mL of neuraminidase. According to the amount of neuraminidase in human serum, the PNAS could monitor the enzyme activity with a good linearity ($R^2$ > 0.99). In addition, the initial performance of the PNAS has been maintained up to 70 days in the $4^{\circ}C$. Finally, we demonstrated whether the Michaelis-Menten kinetics is applied to the PNAS, which can show the reliability of the enzyme reactions. The kinetic studies indicated that the PNAS provides the good condition for enzyme reactions ($K_m=8.327{\times}10^{-3}M$), but they were performed on paper chip nonetheless. The paper-based neuraminidase assay sensor may be useful in a wide range of rapid and safe detection of influenza virus.

Fabrication of 3D Paper-based Analytical Device Using Double-Sided Imprinting Method for Metal Ion Detection (양면 인쇄법을 이용한 중금속 검출용 3D 종이 기반 분석장치 제작)

  • Jinsol, Choi;Heon-Ho, Jeong
    • Clean Technology
    • /
    • v.28 no.4
    • /
    • pp.323-330
    • /
    • 2022
  • Microfluidic paper-based analytical devices (μPADs) have recently been in the spotlight for their applicability in point-of-care diagnostics and environmental material detection. This study presents a double-sided printing method for fabricating 3D-μPADs, providing simple and cost effective metal ion detection. The design of the 3D-μPAD was made into an acryl stamp by laser cutting and then coating it with a thin layer of PDMS using the spin-coating method. This fabricated stamp was used to form the 3D structure of the hydrophobic barrier through a double-sided contact printing method. The fabrication of the 3D hydrophobic barrier within a single sheet was optimized by controlling the spin-coating rate, reagent ratio and contacting time. The optimal conditions were found by analyzing the area change of the PDMS hydrophobic barrier and hydrophilic channel using ink with chromatography paper. Using the fabricated 3D-μPAD under optimized conditions, Ni2+, Cu2+, Hg2+, and pH were detected at different concentrations and displayed with color intensity in grayscale for quantitative analysis using ImageJ. This study demonstrated that a 3D-μPAD biosensor can be applied to detect metal ions without special analysis equipment. This 3D-μPAD provides a highly portable and rapid on-site monitoring platform for detecting multiple heavy metal ions with extremely high repeatability, which is useful for resource-limited areas and developing countries.