• Title/Summary/Keyword: 비상전원

Search Result 146, Processing Time 0.022 seconds

Performance Test of Three Phase 250kW Hybrid PCS for Demand Management including the Function of Emergency Power Supply (비상전원공급 기능을 갖는 250kW급 수요관리용 3상 하이브리드 PCS의 성능시험)

  • Lee, Taeseung;Hwang, Dongok;Paik, Seokmin;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.64-66
    • /
    • 2016
  • 본 논문에서는 당사가 설계 및 제작한 비상전원공급 기능을 갖는 250kW급 수요관리용 3상 하이브리드 PCS의 주요 전기적 특성을 분석 한다. 충전모드에서 운전시 PWM 컨버터의 입력역률, 입력전류 THD 및 전력변환 효율과 방전모드에서 운전시 계통으로 주입되는 역률과 전류 THD 및 효율을 각각 측정 및 분석하였다. 또한 각 운전모드별 동작 상태와 비상운전모드로의 절환시간을 측정 및 분석하였다.

  • PDF

Railway system standby power Nickel metal hydride battery (철도시스템비상전원용 니켈수소(NiMH)전지)

  • Park, Dong-Pil
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.636-645
    • /
    • 2006
  • In order to use railway system standby power, produced 160Ah NiMH battery that would be able to substitute the lead acid battery or NiCd battery form which contain the toxic material in environment, using parallel connected 80Ah NiMH battery. And in order to develop proper electrode in the 160Ah NiMH battery, tested high rate discharge performance of the ternary electrolyte. 160Ah NiMH battery evaluated the various test in order to use railway system standby power.

  • PDF

A study on the Controller Development Depending Load Variation of a Diesel Generator for Power System Connection of Distributed-source (분산전원의 계통연계를 위한 디젤발전기의 부하변동에 따른 제어기 개발연구)

  • Han, Sang-Seok;Han, Hoo-Sek;Lee, Chang-Goo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.53-57
    • /
    • 2008
  • Diesel generator is most widely used for supplying of emergency electrical power. There have been extensive research efforts to develop ways to Ensure stable electrical power delivery to the loads using hybrid power sutures, such as power source, storage batteries, fuel cells and solar cells. Furthermore, as the role of these diesel generators for emergency electrical power supply has recently become very important, they should assure high reliability and flexibility according to the operation load. Therefore, in this paper, we introduce a controller to be used in diesel generator toenable tracking control of maximum power according to the load variation and suppressing high-order harmonics while maintaining stable frequency.

Multi Remote Control of Ship's Emergency Lighting Power Supply (선박 비상조명 전원장치의 다중 원격제어)

  • Lee Sung-Geun;Lim Hyun-Jung
    • Journal of Navigation and Port Research
    • /
    • v.29 no.10 s.106
    • /
    • pp.859-863
    • /
    • 2005
  • This paper describes the improvement of power control characteristics of ship's emergency lighting power supply(SELPS), by which electric power is controlled extensively, and power ON-OFF is controlled and system parameter monitored in remote distance by PC serial communication. Proposed system is composed of step-down converter(SDC), emergency power supply circuit(EPSC), half bridge(HB) inverter, fluorescent lamp(FL) starting circuit, microprocessor control and multi communication circuit. Experimental works confirm that relative system stops when over current is detected and speedy and stable emergency power is supplied when main power source cut-off, and controls input power up to 35[$\%$] by adjusting pulse frequency of the HB inverter, and ON-OFF control of multiple SELS, real time transmission and monitor of parameters as to voltage, current, and power values are performed appropriately by PC communication.

A Buoyant Combined Solar-Wave Power Generation and Its Application for Emergency Power Supply of Nuclear Power Plant (부유식 태양광-파력 복합발전 개념 및 원자력발전소 비상전원을 위한 응용)

  • Cha, Kyung-Ho;Kim, Jung-Taek
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents a Combined solar-wave Power Generation (CPG) concept that the CPG unit is maintained as buoyant at the level of sea water and it is also supported by a submerged tunnel, with the aim of supplying emergency electric power during the station blackout events of nuclear power plants. The CPG concept has been motivated from the 2011 Fukushima-Daiichi Accidents due to the loss of both offsite AC power and emergency diesel power caused by natural hazards such as earthquake and tsunami. The CPG is conceptualized by applying different types and different sites for emergency power generation, in order to reduce common cause failures of emergency power suppliers due to natural hazards. Thus, the CPG can provide a new mean for supplying emergency electric power during station blackout events of nuclear power plants. For this application, the CPG requirements are described with a typical configuration at the ocean side of a submerged tunnel.

Isolated DC/DC Converter with Very Wide Input Voltage Ranges for Emergency Power Back-up System(EPBS) (비상전원 공급장치를 위한 넓은 입력전압 범위를 갖는 절연형 DC/DC 컨버터)

  • Chae, Hyung-Jun;Kim, Kyoung-Dong;Oh, Hyung-Rock;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.334-341
    • /
    • 2011
  • This paper presents a design and implementation of DC/DC converter with very wide input voltage ranges for EPBS whose input voltage is from 30V to 400V and output voltage is 48V. This converter is comprised of two stages that one is for control and the other is for only galvanic isolation. The proposed converter uses the hard-switched buck-boost topology for control purpose and soft-switched LLC resonant converter for isolation. The proposed converter has been verified with 300W design.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.