Journal of the Korea Academia-Industrial cooperation Society
/
v.19
no.2
/
pp.1-8
/
2018
Levee breaches can result from flooding due to torrential rainfalls, which are linked with recent abnormal climates and the aging of river levees. Breaches have caused enormous property damage and human casualties in lowland areas. Overtopping was found to be the cause for approximately 40% of all cases of breach. In this study, the reasons and mechanisms behind levee breaches were analyzed using hydraulic model testing. The overtopping stability and time delay effect of breaches were assessed for levees made with a new environmentally friendly substance. Image analysis revealed that the total breach time of the levees made with the new substance was about 2.25 times greater than that of an earthen levee. The initial breach rate of a general earthen levee was about 1.43 times higher than that of levees covered with the new substance, and the body collapsed rapidly. The breach mechanisms of levees covered with the new substance were completely different, and it is possible to prevent rapid breaches by mitigation of the breach speed on the slope by resisting overtopping.
Proceedings of the Korea Water Resources Association Conference
/
2017.05a
/
pp.257-257
/
2017
본 연구는 기상이변의 영향으로 지속적으로 발생되고 있는 댐 저수지 붕괴에 대한 원인 분석과 기존의 관련 연구 및 지침 등을 비교 분석하여 현재 실무에서 적용되고 있는 댐 저수지 비상대처계획(EAP) 수립 대상 기준에서 제외되는 시설물의 붕괴 가능성 평가를 통해 EAP 수립 대상의 적정 범위를 제시하고자 하였다. 이를 위해 본 연구에서는 시설물의 붕괴 가능성에 대한 정량적 판단 기준을 각 요인별로 제시하고, EAP 수립 대상에서 제외되는 댐 저수지를 대상으로 붕괴 가능요인을 적용하여 3개 이하의 붕괴요인에 해당될 경우 저위험군, 4개 및 5개의 붕괴요인에 해당될 경우 중위험군과 고위험군으로 각각 분류하여 시설물 붕괴 위험성 정도에 따른 적절한 대응이 이루어질 수 있도록 제안하였다. 댐 저수지 붕괴 사례 분석을 통해 도출된 붕괴 가능성의 주요 요인으로는 저수용량, 제체 높이, 준공 경과연수, 우심피해 및 지진피해 잠재지역이 포함되며, 각 요인별 객관적인 판단기준은 댐 저수용량의 경우 EAP 법적 수립기준 및 과거 붕괴사례 등의 분석을 토대로 붕괴사례 61개소 중에서 약 88%를 차지하는 저수용량 10만톤을 선정하였으며, 댐 높이의 경우 댐의 파괴양상(이종태, 1987)에서 제시한 댐 붕괴부 특성과 미국주댐안전협회(ASDSO: American Society of Dam Safety Official) 학술지인 Dam Safety(2006) 등에서 제안한 기준을 기존의 댐?저수지 붕괴사례에 적용하여 댐 붕괴폭과 댐 높이의 상관관계 분석 결과를 바탕으로 댐 높이 8m 이상을 적정 범위로 고려하였다. 준공 경과연수의 경우에는 국민안전처 "재해위험저수지 댐 관리 지침" 타당성 평가기준인 '시설노후도' 기준과 한국시설안전공단 사회간접자본 노후화 기준에 해당하는 경과연수 기준을 토대로 30년 이상을 기준으로 선정하였으며, 우심피해 및 지진피해 잠재지역은 국민안전처 재해연보(2014)를 기준으로 과거 10년 동안의 우심피해 발생 지역과 기상청 국내 지진 규모 10위권 내에 포함되는 지역을 고려 대상으로 하였다. 본 연구에서 도출한 시설물 붕괴 가능성에 대한 판단기준을 국민안전처에서 고시한 EAP 수립 대상에서 제외되는 지자체 재해위험저수지 354개소에 적용해 본 결과, 저위험군 16개소, 중위험군 5개소, 고위험군 2개소로 각각 조사되었다. 저위험군은 전문 시설물 관리자에 의한 주기적인 시설물 점검 및 관찰이 필요할 것으로 사료되며, 중 고위험군에 속하는 시설물의 경우 본 연구의 결과를 바탕으로 시설물 하류지역의 실질적인 인명 및 경제적 피해 가능성에 대한 보다 면밀한 조사를 통해 EAP 수립 대상 포함여부를 결정하여야 할 것으로 판단된다.
Kim, Tae-Hyung;Han, Kun-Yeun;Son, Jae-Kyung;Kwak, Young-Min
Proceedings of the Korea Water Resources Association Conference
/
2010.05a
/
pp.744-748
/
2010
4대강 살리기 사업에 있어 하천 준설 및 다목적 보 설치는 주요하천 상 하류의 일괄적인 준설을 통한 통수단면 확보로 홍수 소통능력을 극대화 하고, 친환경적 보설치를 통해 하도정비 실시이후에도 현재의 갈수위 이상의 수위를 유지하면서 홍수피해저감효과를 극대화하는 것을 목표로 한다. 4대강 사업시 콘크리트 형식으로 건설될 다목적 보는 월류식 구조물이지만 보의 저부에서 발생하는 양압력이나 기타 재하 하중과의 조합으로 인해 전도나 활동을 일으킬 수 있는 가능성을 가질 수 있고, 보의 규모가 커지고 가동보 등의 복합적인 형태를 가질 경우 보의 붕괴는 콘크리트 중력식 댐의 붕괴와 비슷한 양상을 가질 것으로 판단된다. 본 연구에서는 월류 구조물이 붕괴되었을때 상 하류 하천에 미치는 영향을 분석하고자 하였다. 자연하천 내의 보 붕괴 및 그에 따른 수위상승으로 인한 제방 붕괴시 실제 범람원에 안정적으로 적용가능한 고정확도 2차원 홍수범람 모형을 평가하였고, 가상하도 및 실험하도에 대한 적용을 실시하였다.
This study is performed to investigate the cause of slope failure and to suggest suitable stabilization methods for the failed rock slopes. The slope which is located along the national highway between Maesan and Kakok in Dangjin-gun failed during the construction of roads. Site investigation, drilling program, field measurements, rainfall records, and stability analyses are used to investigate the cause of the slope failure. The problem determining the cut-slope angle based on the existing design manual for the construction of roads is reviewed based on the case history given in this paper. If weakness layer and geological structures such as folds and faults are developed in a slope, slope failure is possible even though the direction of slope and the direction of discontinuities depart more than $30^{\circ}$.
Recently, the number of tunnels on national roads has been increased due to the trend that construction of the large-scaled cut slopes is limited because of the environmental issues. Therefore, the slope failures of tunnel portal have often occurred. The tunnel portal in use has limitations on selection of the countermeasure and construction against slope failure. In the cases of Suanbo hot springs 1 and 2 tunnel portals, seedding was chosen and constructed as the countermeasureof slope failure when the tunnel was first built but collapsed in April, 2002. In this study, the failure sites were examined accurately through the site investigation and an efficient countermeasure according to stability analysis is presented. It is shown that it is very efficient to use resloping for Suanbo hot springs 1 tunnel and concrete buttress, rock anchor to reinforcement countermeasure, and attached rockfall prevention net by dividing the site into 3 sections for Suanbo hot springs 2 tunnel.
Proceedings of the Korea Water Resources Association Conference
/
2007.05a
/
pp.1282-1286
/
2007
우리나라는 매년 여름 발생하는 집중호우로 인해 해마다 많은 인명 및 재산 피해가 발생하고 있다. 집중호우 발생으로 인한 홍수로 인해 홍수범람, 제방붕괴 등이 발생할 경우 그 피해는 실로 막대하다고 할 수 있다. 따라서 피해 발생 이전에 충분한 준비를 통해 집중호우로 인한 피해 방지를 준비해야 한다. 지난 2006년 7월 전국적인 국지적 집중호우로 인해 막대한 피해가 발생했으며, 남강의 지류인 영천강 유역에서도 제방의 월류 붕괴로 인한 제내지 범람 피해가 다수 발생하였다. 본 연구에서는 2006년 7월 태풍 에위니아 내습시 낙동강수계 남강 유역에 발생한 홍수피해 원인을 분석하기 위하여 수리학적 모형을 이용하여 홍수위를 추정하였다. 영천강은 남강 제1지류이며 남강하구에서 63.0 km 지점인 진양군 문산면 소문리에서 남강에 합류되고 있으며 유로연장은 35 km 이다. 수리학적 모형을 통해 홍수위와 같은 기본적인 수리량의 산정 및 분석을 실시하였다. 본 연구를 통한 결과는 영천강 유역의 제방붕괴 원인 및 홍수범람 피해 방지를 위한 대책 수립뿐만 아니라 상류 유역에 대한 1차원 수리학적 모형의 적용과 관련하여 기초적인 자료로 제공할 것으로 기대된다.
This paper presents a case history of a geosynthetics-reinforced segmental retaining wall, which collapsed during a sever rainfall immediately after the completion of the wall construction. In an attempt to identify possible causes for the collapse, a comprehensive investigation was carried out including physical and strength tests on the backfill, stability analyses on the as-built design based on the current design approaches, and slope stability analyses with pore pressure consideration. The investigation revealed that the inappropriate as-built design and the bad-quality backfill were mainly responsible for the collapse. This paper describes the site condition including wall design, details of the results of investigation and finally, lessons learned. Practical significance of the findings from this study is also discussed.
In recent rainy seasons, severe rain storms have caused frequent reinforced retaining wall collapses and slope sliding which have lead to casualties. In this paper, investigating cases of reinforced retaining wall failure, the causes of cracks in reinforced retaining wall and slope sliding have been examined, and a finite element analysis considering the construction phase has been done to analyze the cause and characteristics of slope sliding. As a result, reinforced retaining wall displacement has increased due to heavy rain storms and the increase size has been shown to be large. From these results, it has been analyzed that pile driving can have an effect on the collapse of reinforced retaining walls.
This paper describes a restoration of retaining wall, which was collapsed by rainfall. The failure causes was analyzed by field case, and then the countermeasure was suggested. The failure causes confirmed that observance of design and construction criteria was insufficient. It also was the climate condition like a rainfall and inappropriate construction management. The stability analysis for retaining wall, soil improvement and reinforced earth wall was conducted to confirm validity of the countermeasure. The analysis results showed that the suggested construction method satisfied in required safety factors. Therefore, it should be secured the stability of the structure based on the application of appropriate design method and construction management, when structure was constructed.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.