• Title/Summary/Keyword: 불완전한 보정기

Search Result 5, Processing Time 0.023 seconds

Design of a Free-form Mueller Matrix Ellipsometer with Imperfect Compensators (불완전한 보정기를 적용한 자유형 뮬러행렬타원계의 설계)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.2
    • /
    • pp.59-66
    • /
    • 2022
  • A free-form Mueller matrix ellipsometer (MME) based on independent control of the azimuthal angle of each polarizing element is introduced. The azimuthal angles of the polarizer and the matching compensator which generate the optimum Stokes vectors of an incident beam are investigated for the polarization state generator, where the spectral responses of the retardation angle and transmittance ratio of a nonideal compensator are taken into account. Similarly, the azimuthal angles of the analyzer and the corresponding compensator are investigated for the polarization-state detector, to unambiguously determine the Stokes vector of the outcoming beam from the sample, and explicit expressions for the Stokes elements are derived. Since the suggested technique enables one to utilize a nonideal quarter-wave plate as the compensator for an MME, it will contribute to the construction and application of a Mueller matrix spectroscopic ellipsometer (MMSE) operating over a wide spectral range from deep ultra-violet to near infrared.

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

Kinematic Correction and a Design for Velocity Trajectory to Reduce an Odometer Error of Wheeled-Mobile Robots (구륜 이동 로봇의 주행오차 감소를 위한 기구학적 보정과 속도궤적의 설계)

  • Kim, Jong-Su;Mun, Jong-U;Park, Jong-Guk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.3
    • /
    • pp.9-18
    • /
    • 2000
  • This paper presents methods for reducing odometer errors caused by kinematic imperfections in wheeled mobile robots. Wheel diameters and wheelbase are corrected by using encoders without landmarks. And a new velocity trajectory is proposed that compensates for an orientation error due to acceleration-resolution constraints on motor controllers. Based on this velocity trajectory, the wheel velocity of one out of two driven wheels may be changed by the traveled distance of the mobile robot. It is shown that a wheeled mobile robot can't move along a straight line exactly, even if kinematic correction are achieved perfectly, and this phenomenon is attributable to acceleration-resolution constraints on motor controllers. We experiment on a wheeled mobile robot with 2 d.o.f. and discuss the results.

  • PDF

Development of Column ion Exchange Modeling with Successive Ion Exchange Equilibrium (연속이온교환평형 칼럼 모델 개발)

  • 이인형
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.141-145
    • /
    • 2002
  • Successive ion Exchange Column model was developed with the combination of mass action law and mole balance equation. consuming that ions entering the ion exchange bed pass the resin layer via consecutive ion exchange equilibrium. The application of the model to condensate polishing demineralizer in nuclear power plants indicates that the leakage of $Na^+$ and $Cl^-$ depends upon the degree of resin regeneration and that the ratio of specific ion concentration in Influent to in effluent is subject to the characteristics of resin and solution. The model can account for the local in-equilibrium with the correction of resin concentration and also can be applicable to a competitive ion exchange.

  • PDF

Role of Radiation Therapy for Stage III Thymoma (제 3기 흉선종에서 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.16-20
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of the postoperative radiation therapy for patients with Stage III thymoma and to define the optimal radiotherapeutic regimen Materials and Methods : We retrospectively analyzed the records of 24 patients with Stage III thymoma who were referred for postoperative radiation therapy in our institution from June, 1987 to May, 1999. Surgical therapy consisted of total resection in one patient, subtotal resection in seventeen, and biopsy alone in six patients. Age of the patients was ranged from 20 to 62 years with mean age of 47 years. Male to female ratio was 14 to 10. Radiation therapy was delivered with linear accelerator producing either 6 MeV or 10 MeV photons. The irradiated volume included anterior mediastinum and known residual disease. The supraclavicular fossae were not irradiated. The delivered total dose was ranged from 30 to 56 Gy. One patient received 30 Gy and eighteen patients received minimum of 50 Gy. Follow up period was ranged from 12 months to 8 years with median follow up of 40 months. Results : The overall local control rate for entire group of patients was $67\%$ at 5 years. The cumulative local failure rates at one, three and five year were $18\%,\;28\%\;and\;33\%$, respectively. In patients treated with subtotal resection and biopsy alone, local control rate was $76\%\;and\;33\%$, respectively. The actuarial observed survival rate at 5 years was $57\%$, and actuarial adjusted survival at 5 years was $72\%$. The difference between 5 year survival rates for patients treated with subtotal resection and biopsy alone was not statistically significant $(62\%\;vs\;30\%)$. Conclusion : We might conclude that postoperative radiation therapy was safe and effective treatment for patients with Stage III thymoma. Postoperative radiation therapy is recommended in cases where tumor margin is close or incomplete resection is accomplished.

  • PDF