• Title/Summary/Keyword: 분산 방법

Search Result 5,272, Processing Time 0.034 seconds

A Cohort Study of Incidence Rate and Causes of School Accidents in a Boys' Middle School in Taegu (남자중학교 학생의 학교사고 발생률과 사고원인에 관한 코호트 연구)

  • Park, Jung-Han;Park, Mi-Wha
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.331-340
    • /
    • 1987
  • To determine the incidence rate of school accidents and its associated factors, a cohort observation was carried out in a boys' high school of a total of 2,324 students for an academic year from March 1986 to February 1987. Data for accidents were collected by the author (school nurse) as students came to the school health station for treatment of accidental injury. Data for school activities were obtained from the diary of academic affairs. A total of 603 students made 1,126 visits to the station for accidental injury during the study period that gave an average 1.9 accidents per student. The average number of visits for accidental injury per day was 5.1 and the incidence rate of accidental injury was 2.2 per 1,000 student days. Each class had about 30 accidents on the average in a year. However there were two classes that had exceptionally high incidence rate of accidents; 54 accidents in one class where 10 athletes were assigned and 58 accidents in the other class where the teacher in charge was On vacation for two months. The highest incidence rate of accident was observed in June (3.4 per 1,000 student days) and the lowest rates were in December and February (1.5 and 0.7 per 1,000 student days, respectively) and there were no appreciable difference by day of week. Accidents were caused by mischief or carelessness of students in 62.2% and by the inappropriate tools and facilities of school in 18.6% . The accidents caused by tools and facilities were mainly due to the antiquated chairs and tables. Referral rate to hospital for severe injury was three times higher in cloudy days and five times higher in rainy days than in clear days. There was almost no accident during the examination period but increased after the examination. Based on these findings, following measures are recommended to prevent school accident: disperse the athletes throughout the classes: should the teacher in charge leave the class for a long period, replace with another teacher who is familiar with the class to keep order; replace or repair the inappropriate tools and facilities; and warn the students for the risk of accident or broadcast music or let the students have light physical exercise to relieve the tension in cloudy or rainy day and after examination.

  • PDF

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

Study of Anti-oxidant Analysis to Vegetable Juice Containing Barley Sprouts (보리새싹 함유 녹즙의 항산화력 분석에 관한 연구)

  • Yoo, In-Sik;Baek, Cheong-Mok;Joung, Mi-Yeun;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.248-253
    • /
    • 2017
  • This study was conducted to analyze the anti-oxidant activity of green juice containing barley sprouts. The specimens used in the experiments were supplied byCSJ company located in Jincheon-gun, Chungbuk province. Polyphenol and flavonoid was detected in Huttuynia cordata Thunb fermentation sprout juiceat $1.075{\pm}0.174mg/mL$ and $2.736{\pm}0.187\;quercetin\;mg/mL$, in organic dandelion at $1.048{\pm}0.173mg/mL$ and $2.685{\pm}0.245\;quercetin\;mg/mL$, kan andRakat $1.013{\pm}0.083mg/mL$ and $3.624{\pm}0.237\;quercetin\;mg/mL$, broccoli blending juice at $1.494{\pm}0.255mg/mL$ and $3.826{\pm}0.286\;quercetin\;mg/mL$, and barley sprouts at $1.043{\pm}0.220mg/mL$ and $1.990{\pm}0.223\;quercetin\;mg/mL$, respectively.Antioxidant activity testing revealed the electron donating ability of Huttuynia cordata Thunb fermentation sprout juice for DPPH was 81.97%. Moreover, the free radical scavenging ability measured by ABTS assay showed that the activity was increased in the order of broccoli blending juice, Huttuynia cordata Thunb fermentation sprout juice, organic dandelion, 'kan andRak', barley sprout, and thatthe effects were similar to those of ascorbic acid at $100{\mu}g/mL$. Statistical processing is using SPSS 24, analysis of distributed layout and Duncan's multiple range (p<0.05). Therefore, the use of functional assistance material of products in the future indicates that it is worth a healthy functional drink.

Design and Fabrication for the Development of Auto Pattern Maker (자동취형기 개발을 위한 설계 및 제작)

  • Lee, Young-Il;Kim, Jung-Hee;Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2013
  • Purpose: To design and fabricate the auto pattern maker for the development. Methods: we got the necessary data, needed in design, by using CAD. Based on the these data, we fabricated the trial product for the development of the auto pattern maker. Results: The auto pattern maker were composed with combinations of many elements; pattern making assembly, control panel, frame attachment and prober unit. The pattern making assembly was comprised of the cutter, the pattern holder, pattern remover and silence cover which could minimize the sound during the cutting process. The control panel was designed to be connected and operated with the main printed circuit board. The prober could get the eye shape data by scanning of 1.8 degrees around the groove of the frame through the encoding data according to the address. After starting, scanning was carried out in two passes, i.e. one right-handed and one left-handed. Communication connector could send the eye shape data from auto pattern maker to outer system with the RS232C transmission system. By using the one-way analysis of variance, we got the error rate of cut pattern size for ${\Phi}22mm$, ${\Phi}55mm$ and ${\Phi}62mm$. Because F-value was 0.510 and p-value was 0.601, no statistically significant differences were found. Also, the mean cutting error of the auto pattern maker was 0.0274 mm. Conclusions: we could succeed in making the trial product by applying it to the development of the auto pattern maker. The role of this auto pattern maker is to find a exact required size of lens to fit the frame by measuring the frame. The acquired data are transferred to outer system for grinding and finishing with patternless process. Also, the trial product can produce pattern to fit the frame. Therefore, it was confidently expected that the optometrists could handily produce pattern to fit the frame with this trial product and dispense the ophthalmic lens because of its efficiency and convenience compared to the past.

Open Clinical Trial of Morning Light Therapy in Sleep Disturbance of Alcohol Dependent Patients (알코올의존 환자에서의 수면장애에 대한 아침 광치료의 임상시도)

  • Ko, Young-Hoon;Joe, Sook-Haeng;Jeon, Seung-Kyu;Kim, Byoung-Kyu;Kwon, Sung-Min
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.11 no.2
    • /
    • pp.196-204
    • /
    • 2003
  • Objectives: It is known that sedative hypnotics would make cross tolerance with alcohol and deteriorate quality of sleep in alcoholics. Light therapy is effective non-pharmacological intervention for sleep disturbance in circadian phase disorders, jet-lag, shift-work and age-related sleep disorders. Authors would investigate the effects of morning light therapy on sleep of patients with alcohol dependence during recovery state without withdrawal symptoms. Methods: 13 patients with alcohol dependence who have not any alcohol withdrawal symptom were recruited. Light therapy during 1 hour in the morning had been administered by 2500 Lux light box through serial 3 days. Sleep state of subjects were assessed by sleep log and the subjective satisfaction at sleep was by 100 mm visual analogue scale. Sleepiness, depressive mood, anxiety were evaluated by 100mm visual analogue scale at 8 AM, 2 PM and 8 PM. For assessment of performance ability that would be associated with sleepiness and vigilance, trail making test A, B and digit symbol substitution test were performed by two times on base line and 4th day. Univariate repeated-measures ANOVAs were performed for each measures except performance tests which were analysed by paired t-test. Results: Sleep latency and sleep efficiency were significantly improved with light therapy and satisfaction at sleep was. There was no significant difference in sleepiness at 2 PM with light therapy but sleepiness at 8 AM significantly decreased and at 8 PM increased. The time to complete Trail making test and digit symbol substitution test were significantly shortened at 4th day compared with baseline. Fatigue at 8 AM were not significantly changed with light therapy but at 2 PM and 8 PM significantly decreased. Depressive mood and anxiety were not significantly changed with light therapy. Conclusion: Although this study had some limitations, it showed that light therapy would be effective modality on sleep disturbance of patients with alcohol dependence who have recovered from alcohol withdrawal symptoms. It is proposed that short term light therapy could be used clinically for alcoholics with insomnia. In the future, long term controlled studies using more objective tools for sleep are required to further investigate the effect of light therapy in alcoholics.

  • PDF

Factorial Validity of the Korean Version of the Illness Intrusive Rating Scale among Psychiatric Outpatients Mainly Diagnosed with Anxiety or Depressive Disorders (불안 및 우울장애를 주요 진단으로 하는 정신건강의학과 외래환자 대상 한국판 질병침습도 평가척도의 요인 타당도 연구)

  • Cho, Yubin;Kim, Daeho;Kim, Eunkyung;Jo, Hwa Yeon;Yun, Mirim;Lee, Hoseon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.27 no.2
    • /
    • pp.77-84
    • /
    • 2019
  • Objectives : The Illness Intrusiveness Rating Scale (IIRS) is a well-validated self-report instrument for assessing negative impact of chronic illness and/or adverse effects of its treatment on everyday life domains. Although extensive literature probed its psychometric properties in medical illness, little attention was paid for its validity for psychiatric population. This study aimed to test factorial structure of the Korean Version of the IIRS (IIRS-K) in a consecutive sample of psychiatric outpatients. Methods : Data set of 307 first-visit patients of psychiatric clinic at Guri Hanyang univ. Hospital were used. Exploratory and confirmatory factor analysis, internal consistency were tested in IIRS-K. We also checked Spearman's correlation analysis between IIRS-K, Zung's self-report anxiety scale and Zung's self-report depression scale. Results : 76.9% of the patients were with anxiety disorder and depressive disorder. The principal component factor analysis of the IIRS-K extracted three-factor structure accounted for 63.2% of total variance that was contextually similar to the original English version. This three-factor solution showed the best fit when tested confirmatory factor analysis compared to the original IIRS, two-factor model of IIRS-K suggested from medical outpatients, and one-factor solution. The IIRS-K also showed good internal consistency (Cronbach's α=0.90) and good convergent validity with anxiety and depression scales. Conclusions : The IIRS-K showed the three-factor structure that was similar but not identical to original version. Overall, this study proved factorial validity of the IIRS-K and it can be used for Korean clinical population.

A study on the Chinese Animation Industry -Focused on Economic Development in the Animation Market in China- (중국 애니메이션 산업 발전 방향에 관한 연구 -중국 경제 개발 정책에 따른 애니메이션 시장변화를 중심으로-)

  • Kim, Dong-Ho
    • Cartoon and Animation Studies
    • /
    • s.48
    • /
    • pp.311-332
    • /
    • 2017
  • Currently, the world is making efforts to develop cultural industries around more refined parts of the world. The development of cultural industries has far-reaching implications for promoting national brands and national image promotion as well as economic benefits. In particular, China hopes to advance into its own animation market because it has an extensive animation market. In 2005 The Chinese government, however, banned foreign animation market from entering the Chinese animation market. However, at that time, Chinese animation firms also saw considerable economic losses because they had to undergo almost everything from animation to distribution to rationing. In fact, the policy was designed to protect Chinese animations, but instead of preventing Chinese animations from developing original contents, it caused various problems such as China's animations, or the development of Chinese animation industries. In this thesis, we will explore the policy related to animation industry in China, research and development of animation industry, and establish the direction of development of Chinese animation industry through suggestion of improvement in Chinese animation industry. For starters, we have diversified the contents of the Chinese animation industry by adapting the contents of the Chinese animation to the global market through the globalization of contents, stories and materials. Currently, animation is developing beyond 3D,4D and VR but there is no shortage of animation experts in China, so it is necessary to nurture specialized professionals by opening a related department in China. Also, the government will establish a National Animation Industry complex to work in various animation companies. We expect to develop cultural contents through mutual cooperation between animation companies in China and the sharing of information sharing and collaborative research.

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Enhancement of Immune Activities of Peptides from Asterias amurensis Using a Nano-encapsulation Process (나노 입자 불가사리 펩타이드의 면역 활성 증진)

  • Jeong, Hyang-Suk;Oh, Sung-Ho;Kim, Seoung-Seop;Jeong, Myoung-Hoon;Choi, Woon-Yong;Seo, Yong-Chang;Choi, Geun-Pyo;Kim, Jin-Chul;Lee, Hyeon-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.424-430
    • /
    • 2010
  • Immuno-modulatory activities of peptides from Asterias amurensis were investigated using a nano-encapsulation process. The molecular weights of the peptides in the range of 5-7 kDa were separated using Sephadex G-75 gel filtration. Eighty-five percent of the nano-particles were in the 300 nm range using dynamic light scattering. The cytotoxicity of the A. amurensis nano-particles against CCD-986sk human dermal fibroblast cells was 11.64% after adding 1.0 mg/mL of the samples, which was lower than that from the control (13.28% collagen). The secretion of $NO^-$ from macrophages was estimated as $40\;{\mu}M$ after adding 1.0 mg/mL of gelatin nano-particles, which was higher than the others. Prostaglandin $E_2$ production from UV-induced human skin cells decreased greatly to 860 pg/mL after adding 1.0 mg/mL of the samples. Confocal microscopy revealed that nano-particles effectively penetrated the cells within 1 hour. From these results, we consider that nano-encapsulation of the peptides from A. amurensis can improve their biological functions.