• Title/Summary/Keyword: 분산수

Search Result 10,441, Processing Time 0.051 seconds

Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose (근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가)

  • Kweon, Oh-Jin;Jung, Su-Hee;Baek, Seung-Chan;Kim, Kyeong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.93-97
    • /
    • 2009
  • Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

  • PDF

Effects of Mowing (Beolcho) Timing and Height on Growth Characteristics of Zoysia japonica and Z. matrella before Chuseok (추석 전 잔디 깍기(벌초) 시기 및 높이에 따른 들잔디와 금잔디의 생육)

  • Chang, Seog-Won;Koo, Jun-Hak;Sung, Chang-Hyun;Lee, Jeong-Ho;Park, Sho-Jun;Jee, Jae-Uk;Youn, Jeong-Ho
    • Weed & Turfgrass Science
    • /
    • v.7 no.2
    • /
    • pp.140-147
    • /
    • 2018
  • In Korea, mowing the grass of a grave (Beolcho) is a very important event preceded by Chuseok (Korean thanks giving day) and Si-Hyang (annual ancestral feast). Because Beolcho usually takes place one or two weeks before Chuseok, the traffic accidents on roads are getting worse and safety accidents are getting more and more. Erroneous Beolcho methods can cause the soil to be exposed and cause the loss of soil or the low shoot density of graveyard grass or weed occurrence. Therefore, the dispersion of the Beolcho timing and the approprite method can be import issues. The present study assessed the effects of grass mowing timing and height before Chuseok on the growth of Zoysia japonica and Z. matrella. The mowing timing was evaluated at 1 week, 2 weeks, 3 weeks, and 4 weeks before Chuseok, and the mowing height differently according to the two type of grass. In Z. japonica, the faster mowing before Chuseok, the longer the plant height, and the coverage rate and shoot density were higher. In Z. matrella, the faster mowing, the longer the shoot length, but the coverage rate and shoot density did not show any difference or tendency. As compared to Z. japonica, the plant height of Z. matrella was kept short regardless of the time of mowing. In both grasses, the plant height was shortened when mowing was done at low cutting height, but the coverage rate and shoot density were decreased. In addition, it was shown that it is advantageous to maintain the shoot density of graveyard lawn by 40-50 mm or 30-40 mm cutting above the ground for Z. japonica or Z. matrella, respectively.

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

UBVI CCD Photometry of NGC 7790 (NGC 7790의 UBVI CCD 측광)

  • Choi, Dong Yeol;Kim, Hee Soo;Lim, Beomdu;Sung, Hwankyung
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.661-673
    • /
    • 2015
  • UBVI CCD photometry of the intermediate age open cluster NGC 7790 has been obtained using AZT-22 1.5 m telescope (f/7.74) at the Maidanak Astronomical Observatory in Uzbekistan. NGC 7790 contains three ${\delta}$ Cep variable stars including CEa Cas, CEb Cas, and CF Cas. PSF photometry was carried out using IRAF/DAOPHOT for all observations. The total number of stars observed both in V and I filter was 1008 and the limiting magnitude was $V{\approx}22$. To determine atmospheric extinction coefficients and photometric zero points, many blue and red standard stars as well as the standard stars in the celestial equator under various airmass were observed. Photometric data were transformed into the standard Johnson-Cousins' UBVI standard system. From the analysis of UBVI color-magnitude diagram and color-color diagram, the color excess in V and I filter [$E(B-V)=0.58{\pm}0.02$], the selective extinction ratio in V and I filter [$R_V{\equiv}A_V/E(B-V)=3.02{\pm}0.09$] and distance modulus ($V_0-M_V=12.65{\pm}0.10$) of the cluster were determined. The age of the cluster was estimated to be log $age=8.05{\pm}0.05$ [yr] based on the position of these three Cepheid variables in the color-magnitude diagram, the isochrone of the Geneva group ($Ekstr{\ddot{o}}m$ et al., 2012-Z=0.019), and the isochrone of the Padova group (Bressan et al., 2012-Z=0.014) were used to compare each other. Of them, the Geneva models that considered stellar rotation well described the position of ${\delta}$ Cepheid variables in the blue loop. Although they were well consistent with standard period-luminosity relation of ${\delta}$ Cepheid variables, three Cepheid variables in NGC 7790 were, on average, brighter by about 0.5 mag than the absolute magnitude estimated from the mean period-luminosity relation at a given period.

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

FEA estimates of margin design in all ceramic crowns (완전 도재관을 위한 지대치 형성시 변연 형태에 따른 응력 분포의 유한요소법적 비교)

  • Han, Sang-Hyun;Cho, Jung-Hyeon;Lee, En-Jung;Jeong, Suk-In;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Statement of problem: Over the past decade, increased demand for esthetically pleasing restorations has led to the development of all-ceramic systems. Recent reports suggest that the all-ceramic crowns have excellent physical properties, wear resistance, and color stability. In addition, numerous ceramics have excellent biocompatibility, a natural appearance, and improved physical bonding with resin composite luting agents. However, the brittle nature of ceramics has been a major factor in their restriction for universal usage. Functional occlusal loading can generate stress in the luting agent, and the stress distribution may be affected by the marginal geometry at the finish line. Tooth preparation for fixed prosthodontics requires a decision regarding the marginal configuration. The design dictates the shape and bulk of the all ceramic crowns and influences the fit at the margin. Purpose: The purpose of this study was to evaluate the stress distribution within marginal configurations of all- ceramic crowns (90-degree shoulder, 110-degree shoulder, 135-degree shoulder). Material and methods: The force is applied from a direction of 45 degrees to the vertical tooth axis. Three-dimensional finite element analysis was selected to determine stress levels and distributions. Results and conclusion: The result of stress level for the shoulder marginal configuration was more effective on stress distribution at 135-degree shoulder margin. But the stresses concentrated around at 135-degree shoulder margin. The stress decreased apically at the surface between cements and alumina core, and increased apically at the surface between alumina core and veneering porcelain.

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

Study on the Insurance and Liability for Damage caused by Space Objects (우주사고와 손해배상)

  • Kim, Sun-Ihee
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.19 no.1
    • /
    • pp.9-35
    • /
    • 2004
  • A launching State shall be absolutely liable to pay compensation for damage caused by its space object on the surface of the earth or to aircraft in flight. The compensation which the launching State shall be liable to pay for damage under "the Convention on International Liability for Damage caused by Space Objects" shall be determined in accordance with international law and the principles of justice and equity, in order to provide such reparation in respect of the damage as will restore the person, natural or juridical, State or international organisation on whose behalf the claim is presented to the condition which would have existed if the damage had not occurred. In the event of damage being caused elsewhere than on the surface of the earth to a space object of one launching State or to persons or property on board such a space object by a space object of another launching State, and of damage thereby being caused to a third State or to its natural or juridical persons, the first two States shall be jointly and severally liable to the third State, to the extent indicated by the following: If the damage has been caused to the third State on the surface of the earth or to aircraft in flight, their liability to the third State shall be absolute; If the damage has been caused to a space object of the third State or to persons or property on board that space object elsewhere than on the surface of the earth, their liability to the third State shall be based on the fault of either of the first two States or on the fault of persons for whom either is responsible. The Insurance requirements are satisfied for a launch or return authorised by a launch permit if the holder of the permit or authorisation is insured against any liability that the holder might incur to pay compensation for any damage to third parties that the launch or return causes; and the Commonwealth is insured against any liability that Commonwealth might incur, under the Liability Convention or otherwise under international law, to pay compensation for such damage. The liability for Damage caused by Space Objects should be regulated in detail in Korea.

  • PDF

Development of Volume Growth Rate Model for Major Quercus Species in Korea (우리나라 주요 참나무류 수종의 재적생장률 추정 모델의 개발)

  • Shin, Man Yong;Kim, Sung Ho;Jeong, Jin-Hyun;Kim, Chong Chan;Jeon, Eo Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.6
    • /
    • pp.627-633
    • /
    • 2008
  • This study was conducted to estimate volume growth rates for major Quercus species distributed in Korea, and based on the data collected from the 5th National Forest Inventory. Volume growth rates were estimated by each age class for each species, and their similarity or distinction was statistically analyzed. It was also intended to compare the resulted volume growth rates with the existing growth rates, and to develope a volume growth rate estimation model for the Quercus species. Six major Quercus species were considered in this study; Quercus acutissima, Quercus aliena, Quercus serrata, Quercus variabilis, Quercus dentata, and Quercus mongolica. Based on the data collected from the 5th National Forest Inventory, the diameter growth rates and the height growth rates were estimated for each species, and then the volume growth rates were estimated with the given diameter and height growth rates. To examine the distinction between species or age classes, statistical analyses such as ANOVA and Duncan's multiple range test were applied. The results indicated that the volume growth rate was 10% in the age class II, 6% in the age class III, and lower in the subsequent classes. In addition, the volume growth rates of Quercus acutissima, Quercus aliena, and Quercus serrata were relatively high compared to those of Quercus variabilis, Quercus dentata, and Quercus mongolica. According to their growth rates, the six Quercus species were classified into two groups; high-growth-rate group and low-growth-rate group. Statistical analysis conducted to examine the difference between and within the groups showed that there is no significant difference within groups, while significant between groups. Based on the results, volume growth rate estimation model were finally developed for each group. The classification of the Quercus species suggested in this study was not the same with that of existing volume growth estimation. Thus, it is necessary to improve the existing volume growth rate or its estimation system.

Relationship between disk displacement of temporomandibular joint and dentofacial asymmetry (측두하악관절 원판 변위와 치열 및 안면부 비대칭의 관계에 대한 연구)

  • Nahm, Kyoung-Soo;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.3 s.98
    • /
    • pp.211-222
    • /
    • 2003
  • The purpose of this study was to determine whether there is an association between disk displacement of the Temporomandibular Joint (TMJ) and dentofacial asymmetry In orthodontic patients. The subjects consisted of 60 female orthodontic patients between the ages of 18 and 38 years (mean age 23.3 years) who had visited the Department of Orthodontics at Seoul National University Dental Hospital from January 2000 to April 2002. On the basis of magnetic resonance imaging (MRI) of their bilateral TMJs, the subjects were divided Into four groups'. bilateral normal group (twenty-one persons); disk displacement of right TMJ group (six persons); disk displacement of left TMJ group (nine persons); and disk displacement of both TMJs group (twenty-four persons) Postero-anterior (PA) cephalograms and diagnostic models which had been taken before orthodontic treatment were measured. In the linear measurements, a line connecting the right and left Latero-Orbitale (Lo) represented the horizontal reference line (H). The vertical reference line (V) was constructed as a line bisecting and running perpendicular to H. One-way analysis of variance (ANOVA) was used to test whether the mean values of measurements between groups were significantly different. In addition, Bonferronil's multiple comparison test was performed at a level of 0.05. The results were as follows; 1 In the diagnostic model analysis, the overjet, nght molar relationship, and left molar relationship were significantly different among the four groups. 2. In the PA cephalometric analysis, differences in the right and left vertical position of the lower first molar and Ag were significantly dissimilar among the four groups. 3. If the disk displacement of TMJ was present on one side, the ipsilateral ramus was shorter, resulting in asymmetry in the vertical position of Ag. This study indicated that dentofacial asymmetry might be related to the disk displacement of TMJ.