Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose

근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가

  • Kweon, Oh-Jin (Department of Nuclear Medicine, Korea cancer center hospital) ;
  • Jung, Su-Hee (Department of Nuclear Medicine, Korea cancer center hospital) ;
  • Baek, Seung-Chan (Department of Nuclear Medicine, Korea cancer center hospital) ;
  • Kim, Kyeong-Ho (Department of Nuclear Medicine, Korea cancer center hospital)
  • Received : 2008.12.03
  • Accepted : 2009.01.02
  • Published : 2009.05.11

Abstract

Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

2006년~2008년 2사분기까지의 2.5년간의 환자 건수는 14,674건이었으며, $^{18}F$-FDG 평균 주사량은 461.5 MBq 였다. 2.5년간 순환근무는 3회 이루어졌고, 10명의 방사선사 중 PET과 Gamma 영역별 1인을 제외한 8명의 순환근무가 시행되었다. 추가로 2008년 3인의 신입인력이 야간에 투입되어 이에 대한 평가도 이루어졌다. 방사선사의 근무연한은 15년 이상이 2인, 10~15년이 3인, 5~10년이 1인, 5년 미만이 3인이었다. 이들의 개인별 피폭선량은 먼저 PET실에 근무를 하고 있을 때가 Gamma 영역에 근무하고 있을 때 보다 더 높게 나왔다. 가장 큰 원인으로는 일일 처리 건수 면에서 PET과 Gamma영역의 차이가 거의 없는 상태에서 $^{99m}Tc$보다는 상대적으로 에너지가 높은 $^{18}F$-FDG를 사용하는데 있다고 본다. 특히 개인별 피폭선량도 근무연한에 따른 분기별 평가에서 서로 다르게 나타났다. 또한 순환근무 초기 1개월째보다는 업무의 연속성을 익힌 3개월째에 더 낮은 피폭선량을 보여 주고 있다. 이는 PET 실의 근무연한이 길수록 업무의 숙달도가 증가하여 개인별 피폭선량은 감소하는 것으로 보인다. 예약실에 근무하는 간호사의 피폭선량은 $^{18}F$-FDG 주사 후 짧은 시간에 환자와의 접촉이 이루어지고 있어 그리 큰 문제점을 보이지는 않았다. 그러나 임신 가능성이 있는 간호사일 경우는 이를 재고해 보아야할 필요가 있다. 순환 근무를 통한 장시간 PET/CT실을 벗어난 상황이 될 경우 대부분의 근무자가 초기 1개월에서 업무의 연속성 결여 및 개인별 피폭선량 증가라는 위험성을 내포하였다. PET/CT 환자의 증가에 따른 PET/CT실 전체의 과도한 피폭을 분산하기 위한 순환 근무제의 도입이 또 다른 문제점을 갖고 있음을 알 수 있다.5,6) 이를 해결하기 위해서는 근무자의 업무재교육과 순환 및 고정 근무제의 적절한 병행을 시행할 필요가 있다고 본다. 또한 고정 근무자는 순환 근무 인력들의 이런 문제점을 해결하기 위해 업무영역에서 표준화된 업무지침서 등을 만들어야 한다.

Keywords