• Title/Summary/Keyword: 분무 냉각

Search Result 112, Processing Time 0.023 seconds

Comparison of Thermal Properties and Surface Structures of Unmodified, Spray-Dried, and Extrusion-Dried Agar (일반한천, 분무건조한천, 압출성형한천의 열 특성 및 표면구조의 비교)

  • 김희구;손홍주
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.2
    • /
    • pp.234-240
    • /
    • 1997
  • Agar has widely been used as medical aids and food ingredients due to its pecular physicochemical and rheological properties. In this paper, the effects of spray drying and extrusion drying on functional properties of agar were investigated to clarify the sol-gel transition mechanism at low temperature and microstructure of agar gel by measuring phase transition by differential scanning calorimetery, structural differences by light microscope and scanning electron microscope observation. The lowest endothermic onset(To), peak(Tp), conclusion(Tc) temperature and enthalpy($\Delta$H) using differential scanning calorimetery were showed in extrusion-dried agar wic were checked in 41.30, 61.72, 80.50 and 0.73cal/g. In cases of unmodified and spray-dried, the values were 81.20, 95.51, 112.14 and 3.22cal/g, and 60.11, 76.45, 89.54 and 1.53cal/g, respectively. When all samples were reheated using differential scanning calorimetery after gelling fully, no significant differences of endothermic To, Tp, Tc and $\Delta$H appeared. The surface structure of unmodified agar powder observed by light microscope and scanning electron microscope appeared a continuous surface without any indication of small pores, gaps or point of discontinuity. In cases of spray-dried agar, the unstable structures with pores was resulted. The microstructures of extrusion-dried agar, however, was solid with large gaps and areas of discontinuity in the surface. From the results above, it was suggested that significant differences in phase transition and surface microstructures were clearly related to the physicochemical changes and rheological properties, solubility and gelling ability of the types of agar gel.

  • PDF

Analysis of Fire Suppression Efficiency for Intermittent Water Spray Pattern by Fire Dynamics Simulator (FDS를 이용한 교번식 미분무방식의 소화 성능 분석)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.216-220
    • /
    • 2008
  • Water mist fire suppression system utilizes the fire suppression features such as cooling of fire source, dilution of ambient oxygen, and shielding of radiation heat with the evaporation of microscopic water droplets. The momentum of water mist is relatively lower than that of larger water droplet and the infiltration of water mist to the fire source is not effective. Contribution of evaporated water vapor is liable to decline to limited portion of fire source due to its light weight and sparse density. On the other hand, the cycling water mist pattern is expected to improve the penetration force of water mist as well as the air expelling capability with the stratified spray characteristics. At this paper, we present the analyzed fire suppression capability of intermittent water spray pattern by use of FDS which is computational fire dynamics fire model. We expect this analysis can support the basic concept to the development of the prototype of water mist nozzle.

A Study on Cooling of Hot Steel Surface by Water-Air Mixed Spray(I) -The Effect of Air Mass Flux on Film Boiling Heat Transfer- (물-공기 혼합분무에 의한 고온 강판 냉각에 대한 연구 (I) -막비등 열전달에 대한 공기질량유속의 영향-)

  • Lee, Pil-Jong;Jin, Sung-Tae;Lee, Sung-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.247-255
    • /
    • 2004
  • The cooling characteristic of water-air mixed spray for high water mass flux is not well defined, compared to that of highly pressurized spray. A series of research program was planned to develop the boiling correlation for whole temperature range in case of water-air mixed spray with high water mass flux. The cooling experiments of hot steel surface with initial temperature of 820$^{\circ}C$ were conducted in unsteady state with relatively high water mass flux. A computer program was developed to calculate the heat flux inversely from measured data by three inserted thermocouples. Finally the effects of water and air mass flux on the averaged film boiling heat flux and wetting temperature were studied. In this 1st report, it is found that the boiling curve was similar to that of highly pressurized spray and the decreased slope of heat flux in film boiling region with respect to surface temperature became steep by increasing air mass flux. Also it is shown that, by increasing air mass flux, the averaged heat flux in film boiling region was increased, and then saturated and the wetting temperature was increased, and then decreased. Finally when the heat flux in film boiling region is compared with that of highly pressurized spray, it is known that the cooling is improved by introducing air up to 60%.

Design and Cold Flow Test of a Multi-injector Engine using Hydrogen Peroxide/Kerosene (과산화수소/케로신을 이용한 다중 분사기 엔진 설계 및 수류 실험)

  • Lee, Yang-Suk;Jeon, Jun-Su;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.1
    • /
    • pp.36-44
    • /
    • 2012
  • Multi-injector rocket engine using high-concentrated hydrogen peroxide and kerosene was designed and manufactured. Design requirements of a rocket engine were determined and main geometrical parameters of rocket engine were determined on the basis of fundament. Six coaxial swirl injectors were mounted on the multi-injector engine. Flow analysis in the hydrogen peroxide manifold was performed to minimize stagnation and recirculation zones. Finally, the optimized hydrogen peroxide manifold was manufactured and cold flow test was carried out to confirm mass flow rate per uni-element, spray pattern and atomization characteristics. The results of cold flow test showed that the mixing head design process was successful and enough to use as a essential database for the development of a full-scale engine.

Effects of Vacuum Cooling Followed by Water Spraying on the Quality of Precooked Skipjack Katsuwonus pelamis (진공분무 냉각에 의한 자숙 가다랑어(Katsuwonus pelamis)의 냉각 및 품질 특성에 관한 연구)

  • Lee, Tae-Hun;Koo, Jae-Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • The cooling of precooked skipjack Katsuwonus pelamis is a critical thermal process in tuna canning because it affects the quality and yield of the canned tuna, as well as productivity. The combined method of vacuum cooling followed by water spraying (VC-WS) was investigated to increase cooling rates, and prevent loss of yield of the precooked tuna during vacuum cooling. For VC-WS, the precooked skipjack was cooled to $30^{\circ}C$ by vacuum at 31 mmHg and then wetted by spraying water for 2 min. The effects of VC-WS on cooling times, cooling loss, color, texture and lipid oxidation of the precooked tuna were compared with conventional spray cooling (SC).The cooling times for precooked skipjack from $75^{\circ}C-30^{\circ}C$ were 11 min for VC-WS and 145 min for SC. The cooling losses were 1.7 % for VC-WS and 1.6 % for SC. Peroxide and thiobarbituric acid (TBA) values of VC-WS were lower than those of SC. The loin of the VC-WS-treated skipjack was brighter and harder than the SC loin, as indicated by higher lightness and hardness values. Based on these results, we believe that the VC-WS process could compensate for the cooling loss of vacuum cooling and minimize changes in quality that occur during cooling of precooked skipjack tuna.

Analysis of Indoor Thermal Environment and Cooling Effects by Ventilation Condition, and Spray irrigation or Nonspray of Single Span Plastic Greenhouses (환기조건 및 관수에 따른 단동 플라스틱 하우스의 냉방효과와 열환경 분석)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.27-39
    • /
    • 2000
  • In this study, we quantitatively compare the cooling effects of single span plastic greenhouses by opening or shutting of toot and side vents, and operation of fan or sprinkler. With those variables, we simultaneously made experiments at 4 greenhouses under equivalent conditions. By the experiments, the shutting of roof and side vents caused the high temperature difference of indoor and outdoor which the crops cannot be cultivated. However, the opening of the windows effectively reduced the indoor temperature and showed uniform temperature distribution in the greenhouses. The sprinkler abruptly reduced the indoor temperature, and showed excellent cooling effects. Finally, this paper provides the fundamental data for environmental control in greenhouses.

  • PDF

Actual State of Practical Use and Cooling Effect of Evaporative Cooling Systems (증발냉각시스템의 활용실태 및 냉방효과)

  • 김문기;유인호;김기성
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.281-287
    • /
    • 1999
  • In order to take a good look at effectiveness of cooling of Fog system and Pad-Fan system, we chose 49 farm households which were installed evaporative cooling system and 2 farm households which were installed Pad-Fan system and Fog system for a test. We execute the test on 29 households out of 49.6 households, which were installed Pad-Fan system, were able to use; however, 6 household out of 9 which were installed Fog system couldn't use it. The main reason was the clogged on nozzle. The cooling efficiency on Pad-Fan system was 77.4%, but it was very poor on Fog system. Since there are many problems on Fog system, we need more research on size of fog, the location of nozzle, control of Fog systems.

  • PDF

Application of Water Mist System for a Power Transformer Room - Fire Extinguishment(Part 1) (변압기실 화재에 대한 미분무수 소화시스템의 적용 - 소화특성을 중심으로(Part 1))

  • Han Yong-Shik;Choi Byung-Il;Kim Myung-Bae
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.32-36
    • /
    • 2005
  • A water mist system was considered as a possible alternative to a gaseous suppression system that can not prevent re-ignition after fire extinguishment for a power transformer room. This study deals with the fire suppression capability of the water mist systems. High-and low-pressure water mist systems were examined to compare efficiency of both systems. The power transformer examined in this study occupied about $7\%$ of a $10m\times10m\times$ transformer room. Full-scale suppression tests were performed for six different fire scenarios: two spray fires, three pool fires and one cascade fire. The fire suppression test results demonstrated that the high-pressure system was superior to the low-pressure system, especially considering oxygen depletion and the ambient temperature distribution.

Experimental Study of Evaporation of Nanofluid Droplet (나노유체 액적의 증발에 관한 실험적 연구)

  • Kim, Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.647-653
    • /
    • 2013
  • The evaporation characteristics of nanofluid droplets on a heated solid surface were experimentally investigated. The experiments were conducted using pure water and a nanofluid of water mixed with CuO nanoparticles, and the solid surface was made of a copper block heated by a nine cartridge heater. The experimental results showed that the evaporation rate of the nanofluid droplet was higher than that of the pure water droplet on the heated solid surface because nanoparticles increased the thermal conductivity of the nanofluid. Furthermore, it was found that the evaporation rate of the nanofluid droplet increased with the solid surface roughness. This may be because the actual area of the liquid-solid interface increased with the solid surface roughness.

Thermal Analysis Comparison of IMO with USCG Design Condition for the INGC During the Cool-down Period (급냉각기간에서 IMO설계조건과 USCG 설계조건에 대한 LMGC 화물탱크의 열해석 비교)

  • Lee, Jung-Hye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1390-1397
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000㎥ class GT-96 membrane type LNG carrier under IMO and USCG design condition. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls down from -4$0^{\circ}C$ to -l3$0^{\circ}C$, and the spraying rate for the cooling of the insulation wall increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the first barrier and the first insulation, which are among the insulation wall, especially in the top side of the insulation wall under IMO and USCG design condition. Also, as the NG temperature distribution is fixed, the outer temperature condition under the design condition has influence on the temperature variation at the insulation. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted under IMO and USCG design condition. From the comparison between two conditions; IMO design condition shows more severe temperature gradient than USCG design condition, therefore, it provides the conservative estimation of the BOG.