• Title/Summary/Keyword: 분당

Search Result 871, Processing Time 0.024 seconds

Analysis of Temperature Changes in Greenhouses with Recirculated Water Curtain System (순환식 수막하우스의 수온에 따른 플라스틱 온실 내 온도변화 분석)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Pyo, Hee-Young;Jeong, Jae-Woan;Kim, Yong-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.93-99
    • /
    • 2015
  • The purpose of this study was to determine the appropriate temperature for water curtain in greenhouses equipped with recirculated water curtain system. The study analyzed the changes in air temperature in non-heated greenhouses for strawberry cultivation based on outdoor temperature, water curtain temperature and night time. Three greenhouse units were used for this study: The first unit was assigned as a control (no water curtain system), two other greenhouses were equipped with recirculated water curtain system with water curtain temperatures of $10^{\circ}C$ and $15^{\circ}C$, respectively. Analysis showed that the indoor temperatures were directly correlated with the outdoor temperature in all experimental greenhouses. Heat insulating effect of $15^{\circ}C$ water curtain was increased by $1.3^{\circ}C$ compared to that in $10^{\circ}C$ water curtain system. The $15^{\circ}C$ water curtain treatment showed the highest average temperature and less temperature variation in comparison with control and $10^{\circ}C$ water curtain treatment. To maintain indoor temperature at $5^{\circ}C$, water curtain temperature of $10^{\circ}C$ was suitable when outdoor minimum and average temperatures were -1.3 and $1.5^{\circ}C$, and water curtain temperature of $15^{\circ}C$ was suitable when outdoor minimum and average temperatures were -4.7 and $-0.2^{\circ}C$, respectively. The highest temperature in greenhouses according to measurements in different periods of night time was observed after sunset (18:30-20:30), and the lowest temperature before sunrise (05:00-07:00). Water curtain maintained a target indoor temperature by acting as a layer of heat transfer insulator which decreased heat loss from greenhouses. Therefore, water temperature in recirculating water curtain systems should be determined by considering outdoor temperatures, changes in temperature at different periods of night time, and cultivated crop.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Sequential use of Intramuscular and Oral Progesterone for Luteal Phase Support in in vitro Fertilization (체외수정시술 환자에서 황체기 보강 시 근주 투여와 경구 투여의 연속적 이용)

  • Kim, Sang-Don;Jee, Byung-Chul;Lee, Jung-Ryeol;Suh, Chang-Suk;Kim, Seok-Hyun;Moon, Shin-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.1
    • /
    • pp.41-48
    • /
    • 2010
  • Objectives: The aim of this study was to assess appropriate time to convert intramuscular progesterone support to oral administration for luteal phase support in in vitro fertilization (IVF). Methods: Seventy-six cycles of IVF in which fetal heart beat was identified after treatment were included. Patients underwent controlled ovarian hyperstimulation with GnRH agonist long protocol (n=7) or GnRH antagonist protocol (n=66). Cryopreserved embryo transfer was performed in three cycles. Luteal support was initiated by daily intramuscular injection of progesterone, and after confirmation of fetal heart beat, converted to oral micronized progesterone (Utrogestan, Laboratoires Besins International, France) 300 mg daily before or after 8 gestational weeks. The oral progesterone was continued for 11 weeks. Results: Overall clinical abortion rate was 3.9% (3/76) and mean time to conversion was $8^{+4}$ gestational weeks ($46{\pm}5.8$ days after oocytes retrieval). The abortion rate was 5.6% (1/17) and 3.4% (2/59) in patients with conversion before 7 weeks and after 8 weeks, respectively, which were not statistically significant (p=0.678). The miscarriages were occurred at $9^{+4}$ weeks, $11^{+3}$ weeks and $11^{+4}$ weeks. Conclusion: Sequential luteal support using intramuscular and oral progesterone yields a relatively low clinical abortion rate. If fetal heart beat confirmed, sequential regimen appears to be safe and convenient method to reduce patients' discomfort induced by multiple injections.

A Clinical study on the Treatment of Pruritus (피부소양증(皮膚瘙痒症) 치료(治療)에 관(關)한 임상적(臨床的) 연구(硏究))

  • Park, Seong-sik
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.2
    • /
    • pp.361-376
    • /
    • 1999
  • 1. Backgrounds and Purpose : Pruritus, one of the most common dermatological symptoms, was clinically examined with a view to a better understanding of its characteristics for more accurate treatment. 2. Method : For 22 months from November in 1997 to September in 1999 we selected outpatients who had consulted for itchiness more than twice in the department of Sasang Constitution of the Pundang Oriental medical hospital, Dongkook University, and 59 of those (35 males and 24 females) were confirmed of their course of treatment. From their medical records and history, we learned the general characteristics and patterns of pruritus, and the qualities and effects of its various treatments. 3. Result and Conclusion : Pruritus was more complained by men than by women and the largest age groups were 20's and 30's. For its suffering period, the duration of 1 month to less than 1 year was the greatest, and most patients had already experienced western medical care. Itchiness affected them almost day and night. In addition, many patients had abnormal bowel habits as a general symptom. According to Sasang Constitution, the Soeumin gave sleep disturbance and indigestion; the Soyangin showed a different pattern in their tongue coatings and bowel habits; the Taeumin had different tongue coatings and sweating pattern. The commonly prescribed herbal formula for pruritus was Gakhangjungisan, Yangkyuksanhwatang, Chungsimyonjatang. As for their efficiency, 61.0 % of patients improved, whereas 39.0 percent did not. Patients aged over 30 showed a more significant improvement than those of 20 years or under, and the duration of less than 1 year was more significantly improved than that of 1 year or more. Those who had no experience in western medical care or had been continuously treated showed a more significant improvement than those with intermittent treatments, and severe pruritus was more significantly improved than mild pruritus.

  • PDF

Weaning Following a 30 Minutes Spontaneous Breathing Trial (30분 자가호흡관찰에 의한 기계적 호흡치료로부터의 이탈)

  • Shin, Jin;Koh, Young-Min;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1326-1331
    • /
    • 1997
  • Background : Weaning is the process of switching a patient from mechanical ventilator to spontaneous breathing. A number of different weaning techniques can be employed. At recent study, conventional spontaneous breathing trial was superior to other techniques, such as intermittent mandatory ventilation(IMV) or pressure support ventilation(PSV). But adequate observation time of the spontaneous breathing trial was not determined. We reported the effectiveness of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotrachial tube. In this study, we tried to shorten the spontaneous breathing time from 60 minutes to 30 minutes. If weaning success was predicted after 30 minutes spontaneous breathing, extubation was done without reconnection with ventilator. Methodes : Subjects consisted of 42 mechanically ventilated patients from August 1994 to July 1995. The weaning trial was done when the patients recovered sufficiently from respiratory failure that originally required ventilatory assistance, the patients became alert and showed stable vital sign, and arterial $O_2$ tension was adequated($PaO_2$ > 55 mmHg) with less than 40% of inspired oxygen fraction. We conducted a careful physical examination when the patients was breathing spontaneously through the endobronchial tube for 30 minutes. We terminated the trial if a patients was any of following signs of distress; cyanosis, diaphoresis, tachypnea(above 30 breaths per minute), and extreme tachycardia. Patients who had none of this features during spontaneous breathing for 30 minutes were extubated promptly. Result : 17 weaning trials of 15 patients were done in 42 mechanically ventilated patients. Successful weaning and extubation was possible in 14 trials of total 17 trials. In this 14 patients, 8 patients were extubated after 30 minutes spontaneous breathing, 3 patients were extubated after 60 minutes spontaneous breathing, and 3 patients needed over 3 hours for extubation from weaning. We found similar overall success rate compared with weaning following a 60 minutes spontaneous breathing trial. Conclusion : From the result of present study, we believe that weaning and extubation from mechanical ventilation following a 30 minutes spontaneous breathing with $O_2$ supply through the endotracheal tube is a simple and effective method.

  • PDF

Application of Noninvasive Positive Pressure Ventilation in Patients with Respiratory Failure (호흡부전 환자에서 비침습적 양압환기법의 적용)

  • Seol, Young Mi;Park, Young Eun;Kim, Seo Rin;Lee, Jae Hyung;Lee, Su Jin;Kim, Ki Uk;Cho, Jin Hoon;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Young Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.26-33
    • /
    • 2006
  • Background: Noninvasive positive pressure ventilation(NPPV) has been increasingly used over the past decade in the management of acute or chronic respiratory failure and weaning of mechanical ventilation. We performed this clinical study to evaluate the usefulness of NPPV in patients who developed acute respiratory failure or post-extubation respiratory failure. Methods: We analysed thirty four patients(sixteen males and eighteen females, mean ages 58 years) who applied NPPV(BIPAP S/T, Respironics co., USA) for respiratory failure or weaning difficulty at medical intensive care unit(MICU), emergency room and general ward of a tertiary hospital. We evaluated the underlying causes of respiratory failure, duration of treatment, the degree of adaptation, complication and predictive parameters of successful outcome. Results: The overall success rate of NPPV was seventy-one percent. The duration of NPPV applying time, baseline blood pressure, pulse rate, respiration rate, $PaO_2$, $PaCO_2$, $SaO_2$ were not different between success group and failure group. But, the baseline pH was higher in the success group. Predictors of success were higher baseline pH, patients with underlying disease of COPD, improvement of vital sign and arterial blood gas value after NPPV application. The success rate in patients with post-extubation respiratory failure was eighty percent. There were no serious complication on applying NPPV except minor complications such as facial skin erythema, abdominal distension & dry mouth. Conclusion: NPPV may be effective treatment in patients with acute respiratory failure or post-extubation respiratory failure in selected cases.

Histomorphometric Study of Sinus Bone Graft using Various Graft Material (다양한 골이식재료를 이용한 상악동 골이식 4개월 후 조직형태계측학적 평가)

  • Lee, Ji-Young;Kim, Young-Kyun;Kim, Su-Gwan;Lim, Sung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • The aim of this study was to evaluate histomorphometrically and compare the efficiency of various bone graft material and autogenous tooth bone graft material which were used in sinus bone graft procedure. Subjects were the 24 patients who had treated with sinus bone graft using lateral approach from October 2007 to September 2009 at SNUBH. The average age was $52.51{\pm}11.86$ years. All cases was taken after 4month of procedure and divided into 3 groups according to bone graft material. Group 1: autogenous tooth bone graft material, Group 2: OrthoblastII(integra lifescience corp. Irvine, US)+Biocera(Osscotec, seoul, korea), group 3: DBX(Synthes, USA)+BioOss(Geistlich Pharm AG, Wolhusen, Switzerland). Total 37 implant placement area were included and evaluated(7 in group 1, 10 in group 2, 20 in group 3). Evaluation of new bone formation, ratio of woven bone to lamellar bone, ratio of new bone to graft material were performed on each tissue section. Kruskal-Wallis test was used for statistical analysis(SPSS Ver. 12.0, USA). New bone formation were $52.5{\pm}10.7%$ in group 1, $52.0{\pm}23.4%$ in group 2, $51.0{\pm}18.3%$ in group 3. There were no statistical significant differences between each groups. Ratio of woven bone to lamella bone were $82.8{\pm}15.3%$ in group 1, $36.7{\pm}59.3%$ in group 2, $31.0{\pm} 51.2%$ in group 3. Ratio of new bone to graft material were $81.3{\pm}10.4%$ in group 1, $72.5{\pm}28.8%$ in group 2, $80.3{\pm}24.0%$ in group 3. After 4 month of healing period, all group showed favorable new bone formation and around graft material and implant. Within limitation of our study, it is suggested that autogenous tooth bone graft material might be used as novel bone graft material for sinus bone graft.

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

The Relation between Microsatellite Instability and the Thymidylate Synthase Expression in Gastric Cancer (위암에서 Microsatellite Instability와 Thymidylate Synthase의 상관관계)

  • Ko, Hyun-Seok;Ahn, Chang-Wook;Kang, Hae-Youn;Kim, Kwang-Il;Hong, Sung-Pyo;Ahn, Dae-Ho
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.169-175
    • /
    • 2008
  • Purpose: The main target of 5-fluorouracil (5-FU) is thymidylate synthase (TS). A high TS expression has been identified as promoting resistance to 5-FU. For colorectal cancers, the response to 5-FU based adjuvant chemotherapy is different according to the microsatellite instability (MSI) status. The reports on the relationship between MSI and the TS expression in colorectal cancer have been inconsistent. No data is available for gastric cancer regarding the relationship between MSI and the TS expression. Therefore, we studied the relationship between MSI and the TS expression in gastric cancer. Materials and Methods: Ninety-nine consecutive patients who underwent radical gastrectomy for gastric cancer from January 2004 to May 2006 at Bundang CHA hospital were studied. MSI was assessed for five markers (BAT25, BAT26, D2S123, D5S346, and D17S250) by PCR and with using an ABI prism 3100 Genetic analyzer. The TS expression was analyzed by immunohistochemistry with using mouse anti-thymidylate synthase monoclonal antibody to the TS 106 clone. Results: Out of the ninety-nine patients, MSS/MSI-L was detected in 92 (92.1%) cases and 7 cases (7.1%) were MSI-H. A negative TS expression was found in 46 (46.5%) cases, a low TS expression was found in 33 (33.3%) and a high TS expression was found in 20 (20.2%). Out of 92 MSS/MSI-L patients, the number of patients with negative, low and high TS expressions were 46 (50%), 30 (32.6%) and 16 (17.4%), respectively. Out of the 7 MSI-H patients, the number of patients with negative, low and high TS expressions were 0 (0%), 3 (42.9%) and 4 (57.1%), respectively. The relationship between MSI-H and a high TS expression was statistically significant. Conclusion: Gastric cancer with MSI-H showed higher levels of a TS expression compared to the gastric cancer with MSS/MSI-L.

  • PDF

ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES (2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착)

  • Han, Sae-Hee;Kim, Eun-Soung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.169-179
    • /
    • 2007
  • This study was to compare the microshear bond strength $({\mu}SBS)$ of light- and chemically cured composites to enamel coupled with four 2-step self-etch adhesives and also to evaluate the incompatibility between 2-step self-etch adhesives and chemically cured composite resin. Crown segments of extracted human molars were cut mesiodistally, and a 1 mm thickness of specimen was made. They were assigned to four groups by adhesives used: SE group (Clearfil SE Bond) AdheSE group (AdheSE), Tyrian group (Tyrian SPE/One-Step Plus), and Contax group (Contax) Each adhesive was applied to a cut enamel surface as per the manufacturer's instruction. Light-cured (Filtek Z250) or chemically cured composite (Luxacore Smartmix Dual) was bonded to the enamel of each specimen using a Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n=20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at 95% level. Also the interface of enamel and composite was evaluated under FE-SEM. The results of this study were as follows ; 1. The ${\mu}SBS$ of the SE Bond group to the enamel was significantly higher than that of the AdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin (p < 0.05). 2. There was not a significant difference among the hdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin. 3. The ${\mu}SBS$ of the light-cured composite resin was significantly higher than that of the chemically cured composite resin when same adhesive was applied to the enamel (p < 0.05). 4. The interface of enamel and all 2-step self-etch adhesives showed close adaptation, and so the incompatibility of the chemically cured composite resin did not show.