• Title/Summary/Keyword: 분광측색장치

Search Result 8, Processing Time 0.022 seconds

Spectrophotometric analysis of the influence to shade of zirconia core on the color of ceramic (지르코니아 코아의 색조부여가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석)

  • Baek, Ki-Hyun;Woo, Yi-Hyung;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.409-419
    • /
    • 2008
  • Statement of problem: At all times people have tried to fabricate tooth restorations using tooth colored materials. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. The basic color of zirconia is white to ivory. The color can be partially adapted by veneering it with ceramic materials. However, it would be better if the substructure could already be adapted to the basic color shade of neighboring teeth. By adaptation to the basic shade, it can help to reduce the necessary layer thickness of the veneer ceramic to achieve the desired color. Purpose: The purpose of this study was to spectrophotometrically evaluate the influence of shading of zirconia core on the final shade of all-ceramic restorations using the CIE $L^{*}a^{*}b^{*}$ system. Material and methods: Core specimens (n = 20 per group) of Lava Frame Zirconia, KaVo Everest Zirconia, Digident CAD/CAM Zirconia were fabricated at 20 mm in diameter and 0.5 mm in thickness. Halves of each groups were shaded in A3 color. These core specimens were veneered with A3 porcelain of the recommended manufacturer at thickness of 0.5 mm. CIE $L^{*}a^{*}b^{*}$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan) at 0.5 mm, 0.4 mm, 0.3 mm in thickness. Color differences were calculated using the equation ${\Delta}E^{*}=[({\Delta}L^{*})2+({\Delta}a^{*})2+({\Delta}b^{*})2]1/2$. Results: 1. In the case where porcelain layer has a thickness of 0.5 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, however Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 2. When the thickness of porcelain layer decreased from 0.5 mm to 0.4 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, on the other hand Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 3. When the thickness of porcelain layer decreased from 0.5 mm to 0.3 mm, clinically perceived color differences were observed from all three groups. Conclusions: Ziroconia system, which is possible to allow shade on core, are thought to be much more favorable to reproduce natural shade compared to systems that is impossible to give shade. Therefore, clinicians ought to choose adequate system for certain clinical situation by considering above specific character.

A Study of the shade of between maxillary and mandibular anterior teeth in the Korean (한국인의 상하악 전치부 색조에 관한 연구)

  • Kim, Tae-Jin; Kwon, Kung-Rock;Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.343-350
    • /
    • 2008
  • Purpose: The purpose of this study was to spectrophotometrically evaluate the shade difference between of maxillary and mandibular anterior teeth in the Korean by the standard of vita classical shade guide using $SpectroShade^{TM}$. Material and methods: In this study, the shades of healthy anterior teeth were examined and analyzed using the digital shade analysis of $SpectroShade^{TM}$. This study examined 80 individuals in their twenties, thirties, fourties, fifities ages and 40 males and 40 females, presenting 12 healthy, unrestored maxillary and mandibular anterior teeth. Tooth brushing and oral prophylaxis were performed prior to evaluation. The $SpectroShade^{TM}$ was used to acquire images of the 12 maxillary and mandibular anterior teeth. These images were analyzed using $SpectroShade^{TM}$ Software, and shade maps of each tooth were acquired. The shade difference of upper and lower, and gender differences and ages difference were investigated and analyzed with CIE $L^{*}a^{*}b^{*}$ color order system. One-Way ANOVA test was used to find out if there were significant differences between groups tested and Sheffe multiple comparison was used to identify where the differences were. Results: 1. Shade differences were significant (P < .05) between maxillary and mandibular central incisor, lateral incisor, canine. 2. No significant differences in shade distribution were seen between lateral incisors and central incisors. 3. Canine's shade difference were more significant than central incisor's and lateral incisors's. 4. No significant differences in shade distribution were seen between genders in maxillary and mandibulr central incisor, lateral incisor, canine. 5. No significant differences in shade distribution were seen in order of years in maxillary and mandibulr central incisor, lateral incisor, canine. Conclusions: The results of this study show that 1. Shade difference was founded in maxillary and mandibular anterior teeth and ${\Delta}E^{*}$ value was more than 2.0. 2. Canine's shade difference were more significant than central incisor's and lateral incisors's and between central incisors and lateral incisors shade differences were no significant. 3. No significant differences in shade distribution were seen between genders in maxillary and mandibular anterior teeth. 4. No significant differences in shade distribution were seen in order of years grade in maxillary and mandibular anterior teeth.

The Effect of Veneering Techniques on the Color Parameters of Y-TZP Based All Ceramic Restoration of Varying Ceramic Core Thickness (지르코니아 코어 두께에 따른 전부도재관의 상부도재 축성방법이 보철물 색조에 미치는 영향)

  • Huh, Sung-Yoon;Son, Ho-Jung;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • The aim of study was to compare the color parameters and mean color difference of porcelain specimens by different veneering technique in order to examine the effect of veneering technique on esthetics of yttria-stabilized tetragonal zirconia polycrystalline(Y-TZP) all ceramic restoration. Three groups of square-shaped core ceramic specimens(14mm in diameter and 0.3, 0.5, 0.7 mm) and two groups of veneering ceramic specimen were prepared for analysis. Color parameter($L^*,a^*,b^*$) and color difference of zirconia core squares and core-veneer specimens were measured with ShadeEye $NCC^{(R)}$ spectrophotometer, respectively. Mean color difference(${\Delta}E^*$)were calculated using color difference formula. Two-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}=0.05$). ${\Delta}E^*$ values were not significantly affected by core thickness and veneering porcelain(p=0.083). The color differences(${\Delta}E^*$) of core-veneer specimens with 0.5, 0.7 mm-A1,A2,A3.5 shade were mostly below 3.7 which was within the clinically acceptable range, while color differences between 0.3 mm-A1,A2 showed more than 3.7. All-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Fracture Strength and Translucency of CAD/CAM Zirconia Crown for Primary Anterior Tooth (CAD/CAM으로 제작한 유전치 지르코니아 전장관의 두께에 따른 파절강도와 반투명도 비교)

  • Ong, Seung-Hwan;Kim, Jongsoo;Kim, Jongbin;Shin, Jisun;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.205-212
    • /
    • 2020
  • The purpose of this study is to evaluate the validity of primary anterior zirconia crown made with Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) technology by analyzing fracture strength and translucency parameter. Zirconia crown was designed with CAD software, using 3D scanned data of #61 tooth model. Crown fabrication was performed with CAM machine using zirconia block. Zirconia crowns were divided into 3 groups according to thickness(0.3, 0.5, and 0.7 mm), and fracture strength was compared with 1.0 mm thickness of resin strip crown. The compressive force was applied with universal testing machine at 30° along the incisal edge at increments of 1 mm/min. For translucency evaluation, 0.3, 0.5, and 0.7 mm thickness of zirconia specimens were fabricated and translucency was measured with spectrophotometer. Among zirconia groups, there was a significant increase in fracture strength as thickness increased (p < 0.05). The fracture strength of zirconia crown was significantly higher than resin strip crown in all groups (p < 0.05). Translucency parameter was highest in 0.3 mm group, and significantly decreased as thickness increased to 0.5 and 0.7 mm (p < 0.05). Thin primary anterior zirconia crown can be designed and fabricated according to individual needs by using CAD/CAM. Restoration with thin crown would reduce the amount of tooth reduction, risk of pulp exposure, and make more esthetic restoration possible.

A Study on Color Difference Discrimination for PVC Deco-Film using Entry-Level Digital Device (보급형 디지털 장비를 이용한 Deco-Film용 PVC의 색차판별에 대한 연구)

  • Im, Hoyoun;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.22 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • Though digital imaging devices such as smart phones, digital cameras and office scanners have improved significantly over the past years, they are seldom used for industrial application. This may be attributable to high level of quality and performance requirement for industrial application, but there lacks a test or an objective evaluation whether the upgraded performance of entry-level device is sufficiently enough to replace existing industrial equipments or not. If there exists an industrial application area where the applicability of entry-level equipment is proved by some objective tests, then companies will be able to reduce investment on expensive industrial equipment. In this study, applicability of entry-level digital devices for color difference discrimination of PVC (Polyvinyl chloride) color sheet is tested. By testing smart phone, digital camera, and office scanner for color difference discrimination, authors have found that office scanner shows consistent result with less measurement error. Additional experiment on comparing office scanner with industrial spectrophotometer has confirmed that there exists high correlation between the two devices' results. Based on this result, office scanner may be applicable to discriminate the color difference of PVC sheet instead of expensive industrial spectrophotometer if proper management criteria are established.

Effect on the Externally Stained IPS e.max Press Porcelain Due to Tooth Brushing (칫솔질이 IPS e.max Press 도재의 외부 stain에 미치는 영향)

  • Park, Chan;Lee, Gyeong-Je;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.213-221
    • /
    • 2012
  • The purpose of this study was to evaluate the stability of external stain that long term attrition caused by tooth brushing affected the color variation of external stain of IPS e.max Press Porcelain. The specimen was made by IPS e.max Press LT ingots, and treated the shade of external staning as Orange, A, B, C, D After conducting horizontal toothbrush strokes about 11,000 / 22,000 / 44,000 / 66,000 / 88,000, Color changers of the external stained layer was measured with SpectroShade$^{tm}$ MICRO(MHT, Italy). The result of this study was obtained as follows: 1. After 11,000 strokes, the color changes of shade were greater in Orange shade than the other 4 shade groups. And even though toothbrush strokes were increased until 88,000, there were no statistical significant color changes about the external stain shade variation. 2. The amount of color variation about increasing of toothbrushing strokes was irregular(no consistent increasing, or decreasing), and it was no statistical significant changes According to these results, the long term tooth-brushing doesn't affect the changes of external stain about IPS e.max press porcelain. And it doesn't reduce the stability of external stain clinically. Later, it will be needed to study other factors affecting the external stain.

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

A STUDY ON THE COLORS OF THE ANTERIOR PRIMARY RESIN TEETH (유치레진치의 전치부 색조연구)

  • Hyun, Hong-Keun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.639-645
    • /
    • 2007
  • Removable or fixed space maintainer could be needed if one or some anterior primary teeth were missing, where resin pontics well-matched to natural primary teeth should be demanded to get an esthetic satisfaction. Resin Natural $Teeth^{TM}$(Nissin dental, Japan) is available currently in Korea, which consists of two shades of colors; type A1 and A2. The purpose of this study is to elucidate the colors of the anterior primary resin teeth and to establish the data to compare those with the natural anterior primary teeth. CIE $L^*a^*b^*s$ were measured each three times labially from 17 sets of maxillary four anterior teeth for type A1 and A2 Resin Natural $Teeth^{TM}$ using ShadeEye $NCC^{TM}$(Shofu, Japan) which is one of spectrophotometers. The data were analysed statistically using Kruskall-Wallis Test and Mann-Whitney U Test. The results were as follows : 1. There were smaller teeth color differences in group A1 than in group A2 when it comes to distributions of ${\Delta}E$, $L^*$ and $b^*$. There were no statistically significant differences of $a^*$ between teeth in the same group(P>0.05). 2. ${\Delta}E$ in group A1 and A2 (maximum ${\Delta}E{\le}1.23$) were very small, which could not be discerned by eyesight. ${\Delta}E$ between mean CIE $L^*a^*b^*s$ of group A1 and A2 was 3.97, which could be discernible by eyesight. 3. Mean measurements of group A1 were $L^*=73.8$, $a^*=-1.8$, $b^*=-4.7$, and those of group A2 were $L^*=75.8$, $a^*=-2.7$, $b^*=-1.4$. It would be recommended that resin teeth compatible to the colors of the natural primary ones needed to be developed by investigating in vivo study.

  • PDF